Description
Reusable paediatric SpO2 catheter
The reusable paediatric SpO2 oxygen saturation catheter (ref. 32907) is the ideal replacement accessory for continuous monitoring of peripheral oxygen saturation in neonatal and paediatric patients weighing 3 to 10 kg. It is a hospital-grade sensor designed for prolonged professional use and offering an excellent cost per use thanks to its reusable nature.
Operation and clinical application
The catheter measures oxygen saturation (SpO2) by pulse oximetry, a non-invasive technique that determines the percentage of oxygen-saturated haemoglobin in arterial blood from the differential absorption of red and infrared light through tissue. This paediatric sensor is applied to the foot, hand or other suitable areas of the infant patient and is connected to the measuring device by a specific extension cable: for the blood pressure monitor-pulse oximeter Ref. 32902 (LEO), use cable ref. 32917, while for pulse oximeters 35100 and 35101, cable ref. 35108 is used. As a reusable product, it must be cleaned and disinfected between patients following the manufacturer’s instructions to ensure correct operation and patient safety.
Technical specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 32907 |
| Catheter type | Reusable paediatric/neonatal SpO2 catheter |
| Target population | Patients weighing 3 to 10 kg |
| Compatibility | Devices Ref. 32902, 35100, 35101, 35151 and 35152 |
| Required cable | 32917 (for 32902) / 35108 (for 35100 and 35101) |
| Sales unit | 1 ud |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040102274 |
Equivalences and cross-references
These catheters have no universal equivalence between manufacturers, as each brand uses its own connectors and protocols; compatibility should always be validated before a tender or replacement. In the catalogue, the paediatric catheter 32907 is complemented by extension cable 32917 (for the LEO 32902 blood pressure monitor-pulse oximeter) and cable 35108 (for the OXY-50 35100/35101 pulse oximeters). Compatible devices in the family include references 32902, 35100, 35101, 35151 and 35152, which share the same range of SpO2 sensors from the manufacturer.
Selection tips and variants
For correct monitoring, select the catheter according to the patient’s weight: this paediatric catheter is indicated for patients weighing 3 to 10 kg. Always check the connector on the measuring device and purchase the appropriate extension cable (32917 for the 32902 or 35108 for models 35100/35101), as the catheter is supplied without a cable. As a reusable accessory, it is advisable to have several units in rotation and to follow the cleaning and disinfection protocol scrupulously between patients. If in doubt about compatibility with your monitor, contact our technical-commercial team for a personalised recommendation.





Reviews
There are no reviews yet.