Description
1. Twin fetal monitor for prenatal monitoring in obstetrics
The EcoTwin LCD fetal monitor (Ref. 35.71-3480) is a tabletop cardiotocograph designed for the continuous monitoring of fetal wellbeing in obstetric consultations, gynaecology clinics, antenatal control rooms and pre-labour rooms. Its twin configuration allows the heart rate of two fetuses to be monitored simultaneously together with maternal uterine activity, with a dual 7″ LCD screen and a 270° rotatable screen that facilitates reading from any position. Compact, robust and with an integrated lithium-ion battery, it ensures uninterrupted operation even in environments without immediate access to the mains power supply.
The unit is supplied ready to use with the complete set of accessories (2 ultrasound catheters, 1 TOCO catheter, event marker, 3 securing straps, 2 rolls of paper and 1 conductive gel), with CE marking and 24-month warranty.
2. Technical explanation of the equipment
The EcoTwin LCD uses external cardiotocography (CTG) technology: two high-sensitivity ultrasound transducers with 9 crystals, with a frequency of 0.985 MHz, detect the fetal heart rate (FHR) of both fetuses by means of the Doppler effect, while the external pressure TOCO catheter records uterine dynamics (contractions). The ultrasound catheters and the tocograph are waterproof (IPX7) and submersible, which facilitates their cleaning and disinfection between patients.
The system processes the signals in real time and displays them on the dual 7″ LCD screen, rotatable through 270°, where the FHR curves (channels FHR1 and FHR2), the tocography and the fetal movements marked by the patient using the event marker can be viewed, with 3 selectable screen modes to adapt the display to the workflow. The internal memory stores up to 450 hours of data, which can be exported to a USB flash drive for archiving or integration into clinical documentation, and the integrated printer uses thermal paper compatible with the HP range, with selectable print scale (international / European) and display of fetal movement on the printed record.
3. Technical Specifications
| Set type | Twin/double-channel fetal cardiotocograph (CTG) |
| Display | Dual 7″ colour LCD, 270° rotatable, 3 selectable screen modes |
| Fetal channels | 2 (FHR1 and FHR2, simultaneous monitoring of two fetuses) |
| Ultrasound transducers | 2 × waterproof 0.985 MHz catheter, 9-crystal high-sensitivity transducer |
| Tocography transducer | 1 × waterproof TOCO catheter (IPX7) for uterine activity |
| Ultrasound frequency / intensity | 0.985 MHz / < 10 mW/cm² |
| Waterproof rating | IPX7 (ultrasound catheters and tocograph) |
| Event marker | Yes, to record fetal movements perceived by the mother |
| Power supply | Mains power or integrated rechargeable lithium-ion battery |
| Data storage | 450 hours of internal data; export to USB memory |
| Printing | Thermal paper, letter size, compatible with the HP range; selectable scale (international / European); fetal movement display on the printout |
| Connectivity | USB for data transfer and LAN interface |
| Alarms | Adjustable upper and lower limits; cross-channel verification (CCV) |
| Languages | German, Spanish, French, English, Italian, Polish, Portuguese, Russian and Turkish (more languages on request) |
| Dimensions | 28.8 × 23.6 × 9.6 cm (width × depth × height) |
| Weight | Approx. 7 kg |
| Mounting | Simple wall-mounting possibility |
| Regulatory classification | CE marking (Medical Devices Directive) |
| Warranty | 24 months |
| Standard accessories included | 2 ultrasound catheters, 1 TOCO catheter, 1 event marker, 1 pack of 3 securing straps, 2 rolls of paper and 1 conductive gel |
4. Equivalences and Cross-References
This cardiotocograph belongs to the family of dual-channel fetal monitors with 7″ screen and 1 MHz catheter in our catalogue. There is no manufacturer-validated equivalence table authorising 1:1 replacement with equipment from other manufacturers; the following comparisons are functional, at category level, and should not be treated as interchangeable without prior technical validation. Before any replacement, the following must be checked one by one: number of fetal channels, frequency and type of catheters (0.985 MHz vs 1–3 MHz), available CTG analysis, print format, storage, connectivity and CE/MDR regulatory classification.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Bionet | FC1400 antepartum twin cardiotocograph, 7″ TFT touchscreen | FC1400 | Comparable by category (not interchangeable 1:1) | Antepartum fetal monitor with real-time detection of twin FHR and uterine activity, 7″ touchscreen and 1 MHz high-sensitivity catheter. Same functional family; verify CTG analysis criteria, screen type (touchscreen) and consumables. |
| Goldway Medical | CTG7 fetal and maternal monitor with 7″ screen | CTG7 | Comparable by category (not interchangeable 1:1) | Rotatable 7″ TFT screen, internal thermal recorder and FHR/TOCO measurement with maternal vital signs option (ECG, NIBP, SpO2) and twin configuration. Comparable bedside unit; confirm catheter frequency and standard accessories before replacing. |
| Contec Medical | CMS800G fetal monitor with optional twin function | CMS800G | Comparable by category (not interchangeable 1:1) | High-sensitivity pulsed Doppler transducer with 9 elements and 1 MHz (matches the crystal configuration and frequency), optional twin monitoring function, integrated thermal recorder and USB/SD storage. Verify battery, screen type and CTG analysis (Fischer, NST, Krebs). |
Other homologous families of bedside cardiotocographs on the market (Huntleigh Sonicaid Team 3 and BD4000xs series, Edan, among others) must be reviewed property by property: number of fetal channels, catheter frequency, CTG analysis, paper format, memory and connectivity, and regulatory classification. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
Why choose this equipment: if your centre manages twin pregnancies or needs to record the FHR of two fetuses simultaneously together with uterine dynamics with dual physical display, this cardiotocograph is the balanced option between features and cost. Its lithium-ion battery, 270° rotatable screen and LAN interface allow it to be used in rooms without a nearby power outlet, adapt the reading to the workflow and integrate it into the centre’s network.
Variants of interest in our catalogue: the EcoTwin LED (Ref. 35.71-3490), from the same family, with 7″ LED screen and twin recording with 2 catheters of 1 MHz; the dual fetal monitor with 7″ TFT touchscreen (Ref. 35.11-4200), with CTG STV analysis and A5 format printer; and the Smart 1 model (Ref. 35.11-7000) for antenatal monitoring of singleton pregnancies on a lower budget. For hospital environments with advanced analysis (Fischer, Krebs, Dawes-Redman) and HL7 connectivity, consider the MCF21A/MCF21B/MCF-21K professional series.
Consumables and accessories: verify the thermal paper compatible with the printer (letter size, HP range), keep specific ultrasound transmission gel in stock and replace the transducer securing straps (e.g., disposable CTG band set). For tenders, volume conditions or validation of alternative equipment from other manufacturers, contact our technical-commercial team.