We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Twin Fetal Cardiotocograph EcoTwin LCD | Dual-Channel Monitor with Dual 7″ Rotatable 270° LCD Screen and 3 Modes, 2 US Catheters 0.985 MHz, USB and Lithium Battery | Ref. 35.71-3480

2.338,20 €

The EcoTwin LCD fetal monitor (Ref. 35.71-3480) is a twin-channel cardiotocograph with dual 7″ rotatable 270° LCD screen and 3 selectable display modes. It incorporates 2 waterproof ultrasound catheters of 0.985 MHz (9 crystals), TOCO catheter IPX7, rechargeable lithium-ion battery, 450 hours of internal storage with export to USB memory and LAN interface. Compatible with HP range thermal paper, multilingual, ideal for obstetric consultations, gynaecological clinics and prenatal control rooms. Includes complete set of accessories and 24-month warranty.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
35.71-3480

Description

1. Twin fetal monitor for prenatal monitoring in obstetrics

The EcoTwin LCD fetal monitor (Ref. 35.71-3480) is a tabletop cardiotocograph designed for the continuous monitoring of fetal wellbeing in obstetric consultations, gynaecology clinics, antenatal control rooms and pre-labour rooms. Its twin configuration allows the heart rate of two fetuses to be monitored simultaneously together with maternal uterine activity, with a dual 7″ LCD screen and a 270° rotatable screen that facilitates reading from any position. Compact, robust and with an integrated lithium-ion battery, it ensures uninterrupted operation even in environments without immediate access to the mains power supply.

The unit is supplied ready to use with the complete set of accessories (2 ultrasound catheters, 1 TOCO catheter, event marker, 3 securing straps, 2 rolls of paper and 1 conductive gel), with CE marking and 24-month warranty.

2. Technical explanation of the equipment

The EcoTwin LCD uses external cardiotocography (CTG) technology: two high-sensitivity ultrasound transducers with 9 crystals, with a frequency of 0.985 MHz, detect the fetal heart rate (FHR) of both fetuses by means of the Doppler effect, while the external pressure TOCO catheter records uterine dynamics (contractions). The ultrasound catheters and the tocograph are waterproof (IPX7) and submersible, which facilitates their cleaning and disinfection between patients.

The system processes the signals in real time and displays them on the dual 7″ LCD screen, rotatable through 270°, where the FHR curves (channels FHR1 and FHR2), the tocography and the fetal movements marked by the patient using the event marker can be viewed, with 3 selectable screen modes to adapt the display to the workflow. The internal memory stores up to 450 hours of data, which can be exported to a USB flash drive for archiving or integration into clinical documentation, and the integrated printer uses thermal paper compatible with the HP range, with selectable print scale (international / European) and display of fetal movement on the printed record.

3. Technical Specifications

Set type Twin/double-channel fetal cardiotocograph (CTG)
Display Dual 7″ colour LCD, 270° rotatable, 3 selectable screen modes
Fetal channels 2 (FHR1 and FHR2, simultaneous monitoring of two fetuses)
Ultrasound transducers 2 × waterproof 0.985 MHz catheter, 9-crystal high-sensitivity transducer
Tocography transducer 1 × waterproof TOCO catheter (IPX7) for uterine activity
Ultrasound frequency / intensity 0.985 MHz / < 10 mW/cm²
Waterproof rating IPX7 (ultrasound catheters and tocograph)
Event marker Yes, to record fetal movements perceived by the mother
Power supply Mains power or integrated rechargeable lithium-ion battery
Data storage 450 hours of internal data; export to USB memory
Printing Thermal paper, letter size, compatible with the HP range; selectable scale (international / European); fetal movement display on the printout
Connectivity USB for data transfer and LAN interface
Alarms Adjustable upper and lower limits; cross-channel verification (CCV)
Languages German, Spanish, French, English, Italian, Polish, Portuguese, Russian and Turkish (more languages on request)
Dimensions 28.8 × 23.6 × 9.6 cm (width × depth × height)
Weight Approx. 7 kg
Mounting Simple wall-mounting possibility
Regulatory classification CE marking (Medical Devices Directive)
Warranty 24 months
Standard accessories included 2 ultrasound catheters, 1 TOCO catheter, 1 event marker, 1 pack of 3 securing straps, 2 rolls of paper and 1 conductive gel

4. Equivalences and Cross-References

This cardiotocograph belongs to the family of dual-channel fetal monitors with 7″ screen and 1 MHz catheter in our catalogue. There is no manufacturer-validated equivalence table authorising 1:1 replacement with equipment from other manufacturers; the following comparisons are functional, at category level, and should not be treated as interchangeable without prior technical validation. Before any replacement, the following must be checked one by one: number of fetal channels, frequency and type of catheters (0.985 MHz vs 1–3 MHz), available CTG analysis, print format, storage, connectivity and CE/MDR regulatory classification.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Bionet FC1400 antepartum twin cardiotocograph, 7″ TFT touchscreen FC1400 Comparable by category (not interchangeable 1:1) Antepartum fetal monitor with real-time detection of twin FHR and uterine activity, 7″ touchscreen and 1 MHz high-sensitivity catheter. Same functional family; verify CTG analysis criteria, screen type (touchscreen) and consumables.
Goldway Medical CTG7 fetal and maternal monitor with 7″ screen CTG7 Comparable by category (not interchangeable 1:1) Rotatable 7″ TFT screen, internal thermal recorder and FHR/TOCO measurement with maternal vital signs option (ECG, NIBP, SpO2) and twin configuration. Comparable bedside unit; confirm catheter frequency and standard accessories before replacing.
Contec Medical CMS800G fetal monitor with optional twin function CMS800G Comparable by category (not interchangeable 1:1) High-sensitivity pulsed Doppler transducer with 9 elements and 1 MHz (matches the crystal configuration and frequency), optional twin monitoring function, integrated thermal recorder and USB/SD storage. Verify battery, screen type and CTG analysis (Fischer, NST, Krebs).

Other homologous families of bedside cardiotocographs on the market (Huntleigh Sonicaid Team 3 and BD4000xs series, Edan, among others) must be reviewed property by property: number of fetal channels, catheter frequency, CTG analysis, paper format, memory and connectivity, and regulatory classification. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.

5. Selection tips and variants of interest

Why choose this equipment: if your centre manages twin pregnancies or needs to record the FHR of two fetuses simultaneously together with uterine dynamics with dual physical display, this cardiotocograph is the balanced option between features and cost. Its lithium-ion battery, 270° rotatable screen and LAN interface allow it to be used in rooms without a nearby power outlet, adapt the reading to the workflow and integrate it into the centre’s network.

Variants of interest in our catalogue: the EcoTwin LED (Ref. 35.71-3490), from the same family, with 7″ LED screen and twin recording with 2 catheters of 1 MHz; the dual fetal monitor with 7″ TFT touchscreen (Ref. 35.11-4200), with CTG STV analysis and A5 format printer; and the Smart 1 model (Ref. 35.11-7000) for antenatal monitoring of singleton pregnancies on a lower budget. For hospital environments with advanced analysis (Fischer, Krebs, Dawes-Redman) and HL7 connectivity, consider the MCF21A/MCF21B/MCF-21K professional series.

Consumables and accessories: verify the thermal paper compatible with the printer (letter size, HP range), keep specific ultrasound transmission gel in stock and replace the transducer securing straps (e.g., disposable CTG band set). For tenders, volume conditions or validation of alternative equipment from other manufacturers, contact our technical-commercial team.

Additional information

Product type

Twin/double-channel fetal cardiotocograph (CTG)

Display

Dual 7" colour LCD, 270° rotatable, 3 selectable screen modes

Fetal channels

2 (FHR1 and FHR2, simultaneous monitoring of two fetuses)

Ultrasound catheters

2 × waterproof 0.985 MHz catheter, 9-crystal high-sensitivity transducer

Tocography catheter

1 × waterproof TOCO catheter (IPX7) for uterine activity

Ultrasonic frequency

0.985 MHz

Ultrasound intensity

< 10 mW/cm²

Waterproof rating

IPX7 (ultrasound catheters and tocograph)

Power supply

Mains power or integrated rechargeable lithium-ion battery

Storage

450 hours of internal data; export to USB memory

Printing

Letter-size thermal paper compatible with HP range; selectable scale (international / European)

Connectivity

USB for data transfer and LAN interface

Alarms

Adjustable upper and lower limits; cross-channel verification (CCV)

Languages

German, Spanish, French, English, Italian, Polish, Portuguese, Russian and Turkish

Dimensions

28.8 × 23.6 × 9.6 cm (width × depth × height)

Weight

Approx. 7 kg

Mounting

Simple wall-mounting possibility

Classification

CE marking (Medical Devices Directive)

Warranty

24 months

Included accessories

2 ultrasound catheters, 1 TOCO catheter, 1 event marker, 3 securing belts, 2 rolls of paper and 1 conductor gel

Reviews

There are no reviews yet.

Be the first to review “Twin Fetal Cardiotocograph EcoTwin LCD | Dual-Channel Monitor with Dual 7″ Rotatable 270° LCD Screen and 3 Modes, 2 US Catheters 0.985 MHz, USB and Lithium Battery | Ref. 35.71-3480”

Your email address will not be published. Required fields are marked *