We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

TOCO Transducer (Ref. 29541) – Original Replacement for FC1400 Fetal Monitors (Codes 29516-7)

294,50 €

Original TOCO transducer (Ref. 29541), official replacement for the uterine contractile activity sensor of the fetal monitors FC1400 (codes 29516-7). Manufacturer spare part to ensure reliable recording of uterine contractions during cardiotocography (CTG) in delivery rooms, obstetrics consultations and fetal monitoring units. Class II A medical device, presentation of 1 piece. For large orders you can request a quote: consult conditions and lead times with your Cahnos advisor.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM29541

You will also find it in

Description

1. Commercial Introduction

The TOCO transducer, reference 29541, is the original replacement for the tocography sensor of the fetal monitors in the FC1400 series (codes 29516-7). It allows the uterine contractile activity recording catheter to be replaced without having to replace the entire monitor, ensuring compatibility, reliability and continuity of care in obstetrics departments, delivery rooms, gynaecology clinics and prenatal care units.

Our technical-commercial team will advise you on supply conditions and lead times tailored to the needs of your centre. For large orders you can request a quote.

2. Technical explanation of the transducer

The TOCO transducer (tocodynamometer) is the external sensor that records uterine contractile activity during external fetal monitoring or cardiotocography (CTG). Placed on the maternal abdomen and secured with abdominal belts, it captures the pressure changes caused by uterine contractions and transmits them to the fetal monitor, which translates them into the tocography curve (UC / TOCO).

This replacement is specifically designed for the fetal monitors in the FC1400 series (code 29516-7), which incorporates an external tocography channel, one-touch push-button control and auto zero adjustment, with a measurement range of 0 to 99. Having a spare TOCO catheter avoids interruptions to recording in services with intensive use.

3. Technical Specifications

The following specifications correspond entirely to the manufacturer’s catalogue (Product_DB.csv):

Manufacturer GIMA
Sales unit 1 pc
Device type Medical device
Device class II A
GMDN 43958
EAN 8023279295412

Available references

Reference Product Sales unit
29541 TOCO transducer – replacement for codes 29516-7 1 pc

Tocography channel characteristics (FC1400 series)

Parameter Specification
Signal input External transducer (TOCO)
Reference control One-touch push-button, auto zero adjustment
Measurement range 0 – 99

4. Equivalences and Cross-References

Reference 29541 corresponds literally to the factory code for the replacement TOCO transducer for the fetal monitors in the FC1400 series (codes 29516-7), marketed by Cahnos under SKU GM29541 with EAN 8023279295412.

There is no 1:1 equivalence table validated by the manufacturer that cross-references this reference with transducers from other manufacturers. As this is an original replacement designed for the FC1400 series, any substitution with third-party sensors must be validated beforehand with the technical department of Cahnos, checking the monitor model, connector and channel compatibility.

5. Selection tips and variants of interest

Check compatibility: this transducer is the replacement for the TOCO sensor of the FC1400 fetal monitors (codes 29516-7). Confirm the exact model of your equipment and the type of connector before placing the order.

Preventive replacement: we recommend having a spare catheter in services with intensive monitoring use to avoid interruptions in cardiotocographic recording.

System accessories: to complete the equipment of your FC1400 fetal monitor, consult the Cahnos catalogue for the abdominal belts for fetal transducers (Ref. 29544 single-patient and Ref. 29545 reusable) and the other accessories and spare parts in the fetal monitoring range. For institutional or volume orders, contact our technical-commercial team: the sale is carried out.

Additional information

Manufacturer reference

29541

Manufacturer

GIMA S.p.A.

Product type

Replacement TOCO transducer (uterine contractile activity sensor)

Compatibility

Fetal monitors FC1400 series (codes 29516-7)

GMDN code

43958

EAN

8023279295412

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “TOCO Transducer (Ref. 29541) – Original Replacement for FC1400 Fetal Monitors (Codes 29516-7)”

Your email address will not be published. Required fields are marked *