We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rechargeable Ni-MH battery 8.4 V 1.9 Ah (15.96 Wh) for Welch Allyn Propaq-LT Vital Signs Monitor 802LTON / 802LTRN | Replaces Ref. 008-0857-00 | Ref. Cahnos 88888181

360,00 €

Rechargeable nickel-metal hydride (Ni-MH) battery, 8.4 V and 1.9 Ah (15.96 Wh) for the Welch Allyn Propaq-LT vital signs monitor, including the 802LTON and 802LTRN variants. Replacement that directly substitutes the original reference 008-0857-00 and installs in the equipment compartment without tools or modifications, with recharging integrated by the monitor itself: it ensures continuity of ECG, SpO2, pressure and temperature monitoring during patient transfers, emergencies and mains power cuts. Cahnos reference 88888181, sold per unit.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888181

Description

1. Reliable power for your Welch Allyn Propaq-LT monitor

The rechargeable Welch Allyn Propaq-LT battery (ref. Cahnos 88888181) is the power replacement recommended for the portable Propaq-LT vital signs monitors, including the 802LTON and 802LTRN housing variants. It is the solution that restores full autonomy to the equipment when no mains power is available: patient transfers, emergencies, ambulances, intra-hospital transport or any power interruption where continuity of monitoring cannot tolerate pauses.

It is a rechargeable cell ready to install in the original compartment without modifications or tools, which directly replaces the factory reference 008-0857-00. A professional replacement with warranty, designed for medical electronics services, biomedical engineering, emergency departments, ICUs and hospital purchasing.

2. How this battery works

The Welch Allyn Propaq-LT vital signs monitors are portable bedside and transport devices that integrate a display, parametric modules (ECG, SpO2, non-invasive blood pressure, temperature) and signal processing electronics. To operate without depending on the mains, they incorporate an internal rechargeable Nickel-Metal Hydride (Ni-MH) battery, a chemistry known for its robustness in continuous charge cycles and its predictable behaviour in medical devices of this generation.

This cell delivers a nominal voltage of 8.4 V with a capacity of 1.9 Ah (1,900 mAh), which represents a total energy of 15.96 Wh. Recharging is carried out automatically while the monitor remains connected to its charger or to the mains. When autonomy is noticeably reduced or the equipment warns of low battery after a few hours of charging, it is time to replace the accumulator. Always keep the spare cell in good condition and use the monitor’s original charger to respect the equipment’s charging parameters.

3. Technical Specifications

Data verified against the internal Cahnos register and the specialist distribution documentation for the Welch Allyn Propaq-LT platform:

Reference Cahnos (SKU) 88888181
Original equipment reference (OEM) 008-0857-00
Application Welch Allyn Propaq-LT vital signs monitor (802LTON / 802LTRN)
Battery type Nickel-Metal Hydride (Ni-MH), rechargeable, maintenance-free
Nominal voltage 8.4 V
Capacity 1.9 Ah (1,900 mAh)
Energy 15.96 Wh
Weight Approximately 0.35 kg
Dimensions 75 x 65 x 50 mm
Device manufacturer Welch Allyn
Recharge Integrated into the monitor (equipment’s own charger)
Installation Direct replacement in the original compartment, without tools
GUDID registration (UDI-DI) DI 00732094033670 (Welch Allyn, Inc., model 901122, class II)
Presentation Unit
Recycling Management in accordance with WEEE regulations

Note: the voltage, capacity and energy indicated correspond to the declared specification for reference 008-0857-00. Always check the compartment and connector of your unit before replacement.

4. Equivalences and Cross-References

Reference 008-0857-00 is the code under which Welch Allyn identifies the internal battery of the Propaq-LT platform (802LTON / 802LTRN); its existence as a catalogue number of Welch Allyn, Inc. is confirmed in the GUDID/FDA regulatory database (DI 00732094033670, model 901122, class II). In specialist distribution, the same platform compartment is also documented with the manufacturer’s own codes 010-0230-03, 008-0873-00 and 008-0869-00, consistently cited alongside 008-0857-00 in multiple independent sources; as they have not been verified against an official Welch Allyn table, they are classified as exact reference equivalence within the same manufacturer pending label validation on the specific unit.

The third-party references listed below come from replacement battery manufacturers that declare they replace this pack and are classified as comparable by category (not 1:1 interchangeable): all use lithium-ion (Li-ion) chemistry compared to the original Ni-MH of this datasheet and have higher capacities, so before replacing, voltage, capacity, chemistry, connector, charging protocol and compartment dimensions must be verified one by one.

Manufacturer / Brand Family / Model Code / Reference Equivalence level Technical differences / Remarks
Welch Allyn Internal battery Propaq-LT 802LTON / 802LTRN 010-0230-03 Exact reference equivalence (same manufacturer) Alternative Welch Allyn number associated with the same battery compartment of the Propaq-LT platform; consistently documented in specialist distribution alongside 008-0857-00. Check the unit label before replacement.
Welch Allyn Internal battery Propaq-LT 802LTON / 802LTRN 008-0873-00 Exact reference equivalence (same manufacturer) Welch Allyn code associated with the same compartment of the Propaq-LT platform; cited alongside 008-0857-00 in multiple specialist distribution datasheets. Check connector and compartment before replacing.
Welch Allyn Internal battery Propaq-LT 802LTON / 802LTRN 008-0869-00 Exact reference equivalence (same manufacturer) Welch Allyn code associated with the same compartment of the Propaq-LT platform; cited alongside 008-0857-00 in multiple specialist distribution datasheets. Check connector and compartment before replacing.
Cameron Sino Technology Welch Allyn Propaq-LT medical series CS-WBP802MD (EAN 4894128203728) Comparable by category (not interchangeable 1:1) Li-ion 8.4 V / 2,600 mAh (≈21.84 Wh); declared as a replacement for 008-0857-00, 010-0230-03, 008-0873-00 and 008-0869-00 for Propaq-LT 802LTON / 802LTRN; dimensions ≈128.5 x 71.5 x 36.0 mm and ≈137 g. Chemistry (lithium-ion) and capacity higher than the Ni-MH 1.9 Ah cell of this datasheet: check connector, charging protocol and fit in the compartment before replacement. Confirmed in authorised distribution catalogues.
OSI Batteries (Unipower) Biomedical replacement for Propaq-LT B11802 Comparable by category (not interchangeable 1:1) Li-ion 8.4 V / 2.2 Ah declared as a replacement for OEM 008-0857-00 for the Propaq-LT monitor (supplied as a rebuild). Different chemistry from the original Ni-MH; verify capacity, connector and compartment dimensions before replacing. Confirmed in specialist distribution datasheets.
Kingsener Third-party replacement for Propaq-LT (reused OEM code) 008-0857-00 (Li-ion) Comparable by category (not interchangeable 1:1) Aftermarket replacement that adopts the same OEM code 008-0857-00 but with Li-ion chemistry and a capacity of 2,600 mAh (8.4 V); declared compatible with 802LTON / 802LTRN and 010-0230-03. Chemical and capacity difference compared with the 1.9 Ah Ni-MH cell: confirm that the monitor’s charging electronics accept Li-ion before replacing. Confirmed in the pack manufacturer’s datasheet.

There is no equivalence table validated by the manufacturer that authorises third-party batteries for this equipment; consult the technical department before use in tenders. Before any replacement with other brands’ spare parts, each of the following must be checked one by one: voltage, capacity, chemistry, connector, charging protocol and dimensions against the specific unit.

5. Selection tips and variants of interest

Identify the exact model: this battery corresponds to the Welch Allyn Propaq-LT vital signs monitors, including the 802LTON and 802LTRN variants. Also check the label on the installed battery: the original reference may appear as 008-0857-00, 010-0230-03, 008-0873-00 or 008-0869-00. Do not interchange it with batteries from other models of the same brand without technical validation: each monitor fits a cell with specific voltage, capacity and dimensions.

Ni-MH battery care: avoid regular deep discharges and keep the cell charged if the equipment is to remain idle for long periods; Ni-MH cells self-discharge slowly, so periodic recharging is recommended. Replace the battery when the runtime is noticeably reduced or the monitor indicates low battery, and use only the equipment’s original charger.

Variants of the same Welch Allyn family at Cahnos: for other vital signs monitor platforms, spare parts are available such as the Propaq 8 V (ref. 88888512), the VSM6000 10.8 V (ref. 88888849), the Spot Vital Signs LXI 6.4 V (ref. 88881196 / 88889726), the Connex Spot BATT22 (ref. 88889217) and the VSM300 (ref. 88888655). Do not interchange these references between models: each unit accepts a specific voltage, capacity and geometry.

For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formalised quotation.

Additional information

Manufacturer reference

008-0857-00 (Welch Allyn)

Battery type

Ni-MH (nickel-metal hydride), rechargeable, maintenance-free

Technology

Ni-MH

Nominal voltage

8.4 V

Capacity

1.9 Ah (1900 mAh)

Energy

15.96 Wh

Dimensions

75 x 65 x 50 mm

Approximate weight

0.35 kg

Compatibility

Welch Allyn Propaq-LT vital signs monitor (802LTON / 802LTRN)

Application

Monitoring of ECG, SpO2, non-invasive blood pressure, respiration and temperature in patient transport, emergency and ICU

Recharge

Integrated into the monitor (equipment's own charger)

Installation

Direct replacement in the original compartment, without tools

Recycling

RAEE/WEEE

GUDID registration

DI 00732094033670 (Welch Allyn, Inc., model 901122, class II)

Alternative references

010-0230-03, 008-0873-00, 008-0869-00 (documented in specialist distribution); CS-WBP802MD (Cameron Sino, comparable by category)

Weight

Approximately 0.35 kg

Device manufacturer

Welch Allyn

Compatible models

Propaq-LT, 802LTON, 802LTRN

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable Ni-MH battery 8.4 V 1.9 Ah (15.96 Wh) for Welch Allyn Propaq-LT Vital Signs Monitor 802LTON / 802LTRN | Replaces Ref. 008-0857-00 | Ref. Cahnos 88888181”

Your email address will not be published. Required fields are marked *