We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Battery 7.4 V 4.2 Ah for Electrocardiograph Schiller/Odam CardioVit AT102+ (MS-2010 · MS-2015) | Original Ref. 4.350071 / 110650-O1 | Ref. Cahnos 88881115

160,00 €

Rechargeable 7.4 V 4.2 Ah lithium-ion battery for the Schiller/Odam CardioVit AT102+ electrocardiograph (compatible with MS-2010, MS-2015 and MS-2015NEU). Replicates the original factory battery with reference 4.350071 / 110650-O1, restores full battery life for ECG recording and thermal printing, and recharges with the device’s internal charger. Direct replacement in the compartment, without adapters or tools. Ref. Cahnos 88881115.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88881115

Description

1. Reliable power for your CardioVit AT102+ electrocardiograph

At Cahnos we offer you the rechargeable lithium-ion battery of 7.4 V and 4.2 Ah (Ref. Cahnos 88881115) for the electrocardiograph Schiller/Odam CardioVit AT102+, a spare part that reproduces the original factory battery with reference 4.350071 / 110650-O1. With this part you will restore the full autonomy of the device, eliminate low-battery warnings and guarantee the immediate availability of the electrocardiographic recording in cardiology clinics, emergency departments, hospitals and diagnostic centres.

It is the ideal solution for medical electronics services and hospital purchasing departments that need to replace the power source of their CardioVit with a reliable, traceable part at a very competitive cost compared to the official spare part. Price per unit; we have stock and fast delivery throughout Spain.

2. How this battery works: technical explanation

The Schiller/Odam CardioVit AT102+ is a compact electrocardiograph from the platform developed by Odam and now integrated into Schiller, capable of operating connected to the mains or powered by its internal battery during examinations, transfers and emergencies. While the device remains plugged in, the battery stays in charging mode; when it is disconnected or in the event of a power cut, it automatically takes over the power supply for the ECG acquisition electronics, the screen and the thermal recorder, without interrupting operation.

This spare part uses lithium-ion chemistry (polymer type depending on batch), which offers high energy density by weight, low self-discharge, no memory effect and a stable voltage throughout the entire cycle. A degraded cell manifests itself with loss of autonomy, low-battery warnings on start-up or interrupted recordings; preventive replacement with this reference restores the original behaviour of the device in a few minutes, without adapters or special tools. Technical note: in the installed base, 7.2 V and 7.4 V variants coexist, which are compatible and commonly used in this device.

3. Technical Specifications

Technical data cross-checked against Cahnos’s internal reference register, the technical data sheet of SKU 88881115 in specialised distribution and spare part manufacturers’ data sheets for the original references 4.350071 / 110650-O1.

Characteristic Specification
Reference Cahnos (SKU) 88881115
Original manufacturer references 4.350071 · 110650-O1 (accessory code)
Other part numbers documented in distribution 4.350068 · 4.350044 (pending confirmation from primary source)
Type / technology Rechargeable lithium-ion (Li-Ion / Li-Po depending on batch), maintenance-free
Nominal voltage 7.4 V (compatible with 7.2 V variants in common use)
Capacity 4.2 Ah (4,200 mAh); approximate energy ≈31 Wh (according to the SKU distribution data sheet)
Approximate dimensions of the pack 73.4 × 68.0 × 20.3 mm (depending on compatible spare parts; check compartment)
Approximate weight 0.19–0.21 kg depending on variant and batch
Rechargeable Yes, via the internal charger of the electrocardiograph
Compatible equipment Schiller/Odam CardioVit AT102+ · MS-2010 · MS-2015 · MS-2015NEU (also documented for Cardiopad XL, device ref. 191002703)
Estimated life 300–500 charge/discharge cycles (according to distribution data sheet)
Mounting type Direct replacement in the battery compartment, without adapters
Presentation 1 unit
Recycling Manage in accordance with WEEE regulations

Compatibility note: confirm the exact model of your device (CardioVit AT102+, MS-2010, MS-2015 or MS-2015NEU) and the reference printed on the label of the removed battery (4.350071, 110650-O1 or another) before replacing.

4. Equivalences and Cross-References

Note on codes: the original reference for this battery is documented as 4.350071 in Schiller’s parts system and as 110650-O1 in the accessories catalogue; both correspond to the same lithium-ion battery assembly for the CardioVit AT102+. In specialised distribution, the numbers 4.350068 and 4.350044 are also documented for the same accumulator (not found in Schiller’s official public catalogue: pending confirmation with the manufacturer before use).

Schiller does not publish an official equivalence table authorising third-party batteries for this device; the references from other manufacturers or distributors indicated match the device, chemistry and voltage, but are classified as comparable by category and require verification of the label, connector and compartment before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Schiller (original device reference) Li-Ion battery for CardioVit AT102+ / MS-2010 / MS-2015 4.350071 · 110650-O1 Exact reference equivalence (same manufacturer) Original reference that this spare part reproduces: lithium-ion, 7.2–7.4 V, 4.2–4.84 Ah depending on generation (Akkumed declares 7.2 V / 4.84 Ah / 34.85 Wh); confirmed in several specialised distribution sources and in Cahnos’s internal register.
Cameron Sino (aftermarket) Medical battery for Schiller CardioVit AT102+ / MS-2010 / MS-2015 / MS-2015NEU CS-SHA102MD Comparable by category (not interchangeable 1:1) Li-Ion 7.4 V / 5,200 mAh (38.48 Wh), dimensions 73.40 × 68.00 × 20.30 mm, 188 g; replaces the original 110650-O1 and 4.350071 according to the manufacturer’s datasheet. Not original Schiller; capacity higher than the 4.2 Ah of this reference: check batch, connector and fit before mounting.
Specialised distribution (battery-mall) Li-Po battery for CardioVit AT102+ / MS-2007 / MS-2010 / MS-2015 SL80240-1 Comparable by category (not interchangeable 1:1) Li-Po 7.4 V / 4,800 mAh; distributor’s warehouse code, quoted for guidance only for purchases and tenders. Confirm the label, connector and compartment bay against the specific unit.

There is no equivalence table validated by the manufacturer (Schiller) for this battery; consult the technical department before using it in a tender. Before accepting an alternative battery, the following must be checked one by one: voltage (7.4 V; 7.2 V compatible), capacity (4.2–5.2 Ah depending on variant), chemistry (rechargeable lithium-ion), pack dimensions (≈73 × 68 × 20 mm) and the connector of the device compartment.

5. Selection tips and variants of interest

  • Identify the exact reference: check on the label of the removed battery the voltage (7.4 V; 7.2 V compatible), the capacity (4.2 Ah) and the chemistry (lithium-ion). Always order by reference (SKU Cahnos 88881115).
  • Do not confuse it with other batteries in the Schiller/Odam family: the CardioVit AT2-AT101-AT102 series uses a sealed 12 V lead-acid cell (Ref. Cahnos 88889703, with a 2.1 Ah variant under Ref. 88888533) and the AT10+ a 21.6 V / 2.3 Ah Li-Ion battery (Ref. Cahnos 88888209). Each variant fits a specific device: always check the cell fitted before buying.
  • Safe replacement: carry out the change with the device switched off; after fitting, leave the electrocardiograph connected to the mains to complete the charge and check that the battery indicator reflects the new status.
  • Preventive maintenance: lithium-ion cells do not exhibit memory effect; if the device always operates plugged in, periodically perform a discharge and recharge cycle. Replace the battery when the runtime is noticeably reduced or the device warns of low battery.
  • Environmental management: take the spent battery to a RAEE/WEEE collection point; never dispose of it as municipal waste.
  • Institutional orders: for tenders or ongoing supply contracts, contact our technical-commercial department stating the model, serial number and reference of the fitted battery; we will confirm compatibility before finalising the order and offer special volume terms.

Additional information

Manufacturer reference

4.350071 / 110650-O1

Other part numbers

4.350068, 4.350044 (documented in specialised distribution; pending confirmation from primary source)

Battery type

Rechargeable lithium-ion (Li-Ion / Li-Po depending on batch), maintenance-free

Nominal voltage

7.4 V (compatible with 7.2 V variants in common use)

Capacity

4.2 Ah (4,200 mAh); approximate energy ≈31 Wh

Dimensions

73.4 × 68.0 × 20.3 mm (depending on compatible spare parts; check compartment)

Approximate weight

0.19–0.21 kg

Rechargeable

Yes (internal charger of the electrocardiograph)

Compatibility

Schiller/Odam CardioVit AT102+, MS-2010, MS-2015, MS-2015NEU (also documented for Cardiopad XL, ref. 191002703)

Estimated life

300–500 cycles (according to distribution data sheet)

Installation

Direct replacement in the battery compartment, without adapters

Recycling

Manage in accordance with WEEE regulations

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Battery 7.4 V 4.2 Ah for Electrocardiograph Schiller/Odam CardioVit AT102+ (MS-2010 · MS-2015) | Original Ref. 4.350071 / 110650-O1 | Ref. Cahnos 88881115”

Your email address will not be published. Required fields are marked *