We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rechargeable Ni-MH battery compatible with Nihon Kohden PVM-2700 / PVM-2701 / PVM-2703 (VISMO) | Original ref. X076 / SB-201P · 9.6 V 3.7 Ah · Ref. Cahnos 88889187

96,00 €

Rechargeable Ni-MH battery, 9.6 V and 3.7 Ah (35.52 Wh) compatible with Nihon Kohden vital signs monitors PVM-2700, PVM-2701 and PVM-2703 (VISMO station), according to factory reference X076 / SB-201P. Direct replacement in the original compartment, with the same dimensions (68 x 71 x 34 mm) and connector as the cell fitted as standard: ensures continuity of ECG, SpO2 and pressure monitoring during transfers, emergencies or supply interruptions, without depending on mains power. Ready-to-install replacement, with charging integrated in the equipment itself, delivery in 24-72 h and B2B volume conditions. Ref. Cahnos 88889187.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88889187

Description

1. Reliable power for your vital signs monitor

Keep your Nihon Kohden vital signs monitor fully operational with this rechargeable battery compatible with factory reference X076 / SB-201P (Ref. Cahnos 88889187). Designed for the PVM27xx family —PVM-2700, PVM-2701, PVM-2703 and VISMO station—, it is the replacement that ensures the equipment’s autonomy in emergencies, intra-hospital transfers, operating theatres and any situation where mains power is unavailable, without compromising continuous patient monitoring.

It is a direct-fit replacement for the monitor’s battery compartment, restoring full operability in minutes at a very contained cost compared to the official replacement. Ideal for medical electronics departments, hospitals, clinics and supply contracts for medical supplies.

2. Technical explanation: how this battery works

The X076 reference is the nickel-metal hydride (Ni-MH) battery that Nihon Kohden fits as standard on the PVM27xx series multiparameter monitors (PVM-2700, PVM-2701, PVM-2703) and on the VISMO station, and which is also identified by the factory designation SB-201P. Internally it groups Ni-MH cells to deliver a nominal voltage of 9.6 V with 3.7 Ah capacity (35.52 Wh of usable energy), sufficient to maintain ECG, SpO2, non-invasive blood pressure and respiratory rate monitoring during transfers and movement of the equipment.

While the monitor is connected to the mains, the battery remains in float charge mode; when it is disconnected or if the supply is interrupted, it automatically takes over powering the display, the monitoring electronics and the measurement modules without interruption. Its Ni-MH chemistry requires no electrolyte maintenance, supports cyclic recharging with the equipment’s own integrated charger and should be replaced when loss of autonomy or a low-battery warning is detected on screen.

3. Technical Specifications

The following specifications correspond to the battery compatible with reference X076 / SB-201P (Ref. Cahnos 88889187), cross-checked against the technical documentation available for the original equipment:

Parameter Detail
Application Vital signs monitors Nihon Kohden PVM-2700, PVM-2701, PVM-2703, VISMO (SB-201P)
Original reference X076 / SB-201P
Technology Ni-MH (nickel-metal hydride), rechargeable
Nominal voltage 9.6 V
Capacity 3.7 Ah (3700 mAh)
Energy 35.52 Wh
Weight Approximately 0.475 kg
Dimensions 68 x 71 x 34 mm
Device manufacturer Nihon Kohden
Mounting type Direct replacement, without adapters or special tools
Load Integrated into the monitor (equipment’s own charger)
Presentation 1 unit
Recycling Do not dispose of as household waste; recycle in accordance with WEEE regulations

4. Equivalences and Cross-References

Nihon Kohden does not publish an official equivalence table authorising third-party batteries for reference X076. The alternatives listed below share the same chemistry (Ni-MH), voltage (9.6 V) and capacity window, and have been cross-checked in catalogues from their own manufacturers or authorised distributors; they are classified as comparable by category, not 1:1 interchangeable, and require verification of capacity, dimensions and connector against the specific equipment before replacement. Reference X076 has not been located in public regulatory databases (GUDID/FDA, EUDAMED).

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Cameron Sino Medical battery for Nihon Kohden PVM-2700 / 2701 / 2703 CS-NK2700MD Comparable by category (not interchangeable 1:1) Ni-MH 9.6 V, 3800 mAh (36.48 Wh), declared dimensions 68.60 x 68.00 x 34.00 mm; replaces X076 / SB-201P. Different manufacturer (not original Nihon Kohden); capacity higher than the 3.7 Ah cell and slightly different dimensions; verify fit and connector. Confirmed in authorised distributor catalogues (EAN 4894128100584).
SES (Sealed Energy Systems) Battery for Nihon Kohden PVM-2700 / Vismo SE303120 Comparable by category (not interchangeable 1:1) Ni-MH 9.6 V, 3800 mAh (36.48 Wh), dimensions 72.0 x 35.0 x 71.0 mm (±1 mm), weight 0.44 kg; OEM reference X076 / SB-201P. Different manufacturer (not original Nihon Kohden); capacity and dimensions different from the original 3.7 Ah cell; confirm fit in the compartment. Confirmed in the manufacturer’s official datasheet.

There is no equivalence table validated by the manufacturer (Nihon Kohden) authorising third-party batteries for reference X076; consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Identify the removed cell: before replacing, check three parameters on the battery label: voltage (9.6 V), technology (Ni-MH) and factory reference (X076 or SB-201P). If your equipment is a PVM-2700, PVM-2701 or PVM-2703 monitor (or VISMO station), this reference is the correct one.
  • Do not confuse it with other batteries in the family: Nihon Kohden uses different X0xx codes depending on the equipment: X060 corresponds to Lifescope A (Ref. Cahnos 88888774), X064 to Lifescope N (Ref. 88888779) and X075 to the BSM-3000 / BSM-6000 series (Ref. 88888786). Only one variant fits each piece of equipment; always check the installed cell before buying. In Cahnos you also have the original brand version for this same reference (Ref. 88888815).
  • Preventive maintenance: Ni-MH cells self-discharge slowly at rest; if the equipment is to remain off for long periods, recharge it periodically and avoid repeated deep discharges to avoid shortening its service life. After replacement, fully charge the battery before first use and allow the monitor to complete its power-on self-test.
  • Tenders and equipment fleets: contact our technical department indicating model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order and offer you special volume conditions.

Additional information

Technology

Ni-MH (nickel-metal hydride), rechargeable

Nominal voltage

9.6 V

Capacity

3.7 Ah (3700 mAh)

Energy

35.52 Wh

Manufacturer reference

X076 / SB-201P (Nihon Kohden)

Dimensions

68 x 71 x 34 mm

Approximate weight

0.475 kg

Compatibility

Monitors Nihon Kohden PVM-2700, PVM-2701, PVM-2703 and VISMO station

Mounting type

Direct replacement, no adapters or tools required

Rechargeable

Yes, via the monitor's integrated charger

Use

ICU, emergency, operating theatres, hospital wards and intra-hospital transfers

Recycling

WEEE

Battery type

Ni-MH (nickel-metal hydride), rechargeable

Weight

Approximately 0.475 kg

Mounting

Direct replacement, no adapters or tools required

Load

Integrated into the monitor (equipment's own charger)