Description
1. Reliable power for your Mindray BeneView T1 vital signs monitor
At Cahnos we offer you the replacement battery for the Mindray BeneView T1 vital signs monitor (Ref. Cahnos 88881063), corresponding to the original manufacturer reference 115-018016-00. It is a rechargeable lithium-ion (Li-ion) battery of 7.4V and 2.3Ah that restores full autonomy to the device for continuous patient monitoring, even when the monitor is not connected to the mains power supply.
It is the ideal solution for biomedical engineering services, medical electronics maintenance and hospital purchasing departments looking for a traceable spare part of proven quality at a very competitive cost compared with the official replacement, without compromising the reliability required for patient monitoring in emergency departments, operating theatre, intrahospital transport and continuous monitoring.
2. Technical explanation: how this battery works
The Mindray BeneView T1 is a compact multiparameter vital signs monitor designed for bedside and transport use, which records ECG, oxygen saturation (SpO2), non-invasive blood pressure and temperature. To ensure patient monitoring when the device is disconnected from the mains, during transfers or in the event of a power cut, the monitor incorporates an internal rechargeable battery that acts as a backup power source: while it remains plugged in, the battery recharges automatically; when it is disconnected or if the power supply is interrupted, the battery takes over powering the control electronics, the display and the alarms, without interrupting monitoring.
This pack uses lithium-ion (Li-ion) chemistry, free from memory effect and with good energy density, with a nominal voltage of 7.4V and a capacity of 2.3Ah (17.02Wh), in a compact format of 73 x 46 x 29 mm and approximately 0.12 kg. When battery life is noticeably reduced or the monitor warns of low battery prematurely, it is time to replace the battery with this reference. It installs directly into the device’s original compartment, with no need for tools or adaptations.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88881063 |
| Original manufacturer reference | 115-018016-00 (Mindray) |
| Other part numbers of the same pack | LI12I002A (model registered in GUDID), LI12I001A, 2ICR19/65 (documented in specialised distribution) |
| GUDID registration (UDI-DI) | 06944904040912, identified as a Li-ion 7.4V / 2500mAh battery, model LI12I002A |
| Technology | Lithium-ion (Li-Ion), rechargeable |
| Nominal voltage | 7.4 V |
| Capacity | 2.3 Ah (2,300 mAh) |
| Energy | 17.02 Wh |
| Dimensions | 73 x 46 x 29 mm |
| Approximate weight | 0.12 kg |
| Application | Mindray BeneView T1 vital signs monitor |
| Rechargeable | Yes; automatic charging with the monitor connected to the mains |
| Professional use | Power supply for vital signs monitors in emergency departments, operating theatre, intrahospital transport and continuous monitoring |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations |
Note: the capacity stated in this datasheet (2.3Ah / 17.02Wh) corresponds to the pack supplied; the manufacturer’s GUDID record identifies the same battery model (LI12I002A) with 7.4V / 2500mAh. As this is a replacement part, it is recommended to check the reference printed on the removed battery before replacement.
4. Equivalences and Cross-References
The original reference 115-018016-00 corresponds to the 7.4V lithium-ion battery that Mindray fits in the BeneView T1 vital signs monitor, and is registered in GUDID under battery model LI12I002A (UDI-DI 06944904040912). In specialised distribution, the codes LI12I001A and 2ICR19/65 consistently appear as part numbers for the same pack, as well as 022-000057-00 and 022-000117-00 in Asian distribution sources. The third-party alternatives listed below share the same chemistry (Li-ion) and voltage (7.4V) and are classified as comparable by category, not 1:1 interchangeable: they require verification of the connector, compartment dimensions and the device’s charging protocol before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cameron Sino | Medical series (Mindray T1 / BeneView T1) | CS-MET100MD | Comparable by category (not interchangeable 1:1) | Li-ion 7.4V / 2,600mAh (~19.24Wh), dimensions ≈74.1 x 46.9 x 24.0 mm; consistently documented as a replacement for 115-018016-00, LI12I001A, LI12I002A and 2ICR19/65 for Mindray T1 / BeneView T1. Higher capacity (2,600mAh vs 2,300mAh); verify pack dimensions and connector. Manufacturer and authorised distribution datasheets consulted. |
| R&D Batteries | GUDID (OEM 7.4V / 2.5Ah Li-Ion) | 00810149090103 (model 115-018016-00) | Comparable by category (not interchangeable 1:1) | Registered in GUDID under the full description “7.4 Volt 2.5Ah Li-Ion OEM” with Version or Model 115-018016-00. Slightly higher capacity (2.5Ah); confirm housing and connection before replacing. |
There is no equivalence table validated by the manufacturer (Mindray) authorising third-party batteries for reference 115-018016-00; consult the technical department before use in tenders. Before a replacement, the following must be verified one by one: voltage (7.4V), chemistry (Li-ion), capacity, compartment dimensions and the device connector.
5. Selection tips and variants of interest
Identify the monitor and the reference: this 7.4V / 2.3Ah battery is the one indicated for the Mindray BeneView T1 vital signs monitor. Confirm on the label of the removed battery the code 115-018016-00 (or its alternative part numbers LI12I002A, LI12I001A, 2ICR19/65) before ordering the replacement.
Respect voltage and chemistry: the monitor is configured for 7.4V lithium-ion. Do not install batteries of a different chemistry (Ni-MH, lead) or a different voltage, even if the compartment may look similar.
Do not confuse with other variants of the Mindray family: in the Cahnos catalogue you will find the batteries 115-018012-00 (BeneView T5/T8, 11.1V, Ref. 88888838), 115-018015-00 (Accutorr+, 11.1V, Ref. 88888111) and 115-007858-00 (BeneHeart D3, 14.8V, Ref. 88888837), which belong to other platforms and are not interchangeable 1:1 with the one for the BeneView T1.
Replace upon signs of wear: clearly reduced battery life or low battery warnings within a few hours of charging indicate that the battery has reached the end of its service life. After replacement, leave the monitor connected to the mains to complete the charge and check the battery indicator before returning the device to clinical service.
Place orders by reference: always quote the Cahnos code 88881063 or the original reference 115-018016-00 to avoid confusion with other batteries in the Mindray family. For mixed fleets and tenders, consult our catalogue of batteries for vital signs monitors (Mindray, Philips, GE Healthcare, Spacelabs, Nihon Kohden and others) or contact our technical-commercial department to confirm compatibility and volume conditions.