We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Li-ion Battery 11.1V 4.6Ah for Mindray Accutorr+ Vital Signs Monitor | Original Ref. 115-018015-00 | Ref. Cahnos 88888111

224,00 €

Rechargeable lithium-ion (Li-ion) battery, 11.1V and 4.6Ah (51Wh) corresponding to the original Mindray reference 115-018015-00, designed for the vital signs monitors Accutorr+, Accutorr V, Passport 2, Passport V, PM7000, PM8000, PM9000, Spectrum, Spectrum OR, Trio, DPM3, DPM4, DPM5, iPM9800, VS-800 and the Datascope Ex family. Format 181 x 23 x 60 mm and approximately 0.372 kg: direct replacement in the equipment compartment to ensure continuity of monitoring during transfers, emergencies and power supply cuts. Automatic charging with the monitor plugged in, stable energy and waste management in accordance with RAEE/WEEE. Reference Cahnos 88888111.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888111

Description

1. Reliable power for your vital signs monitor

Keep your vital signs monitor always operational with this rechargeable lithium-ion battery of 11.1V and 4.6Ah, corresponding to the original reference 115-018015-00 from Mindray (Ref. Cahnos 88888111). It is the recommended replacement for the Accutorr+ monitor and the rest of the manufacturer’s compatible platforms: a technically proven, ready-to-install spare part that restores the equipment’s full autonomy in emergency departments, hospital wards, ICU, operating theatre and intra-hospital transport.

Designed for medical electronics departments, biomedical engineering and hospital purchasing, it is a reliable and very cost-effective solution compared with the official replacement, without compromising the safety required for continuous patient monitoring. It is supplied per unit for direct installation in the equipment’s battery compartment.

2. Technical explanation: how this battery works

The vital signs monitors in the Mindray Accutorr (Accutorr+, Accutorr V), Passport, Spectrum, Trio and DPM families incorporate an internal rechargeable battery that acts as a backup and portable power source. While the monitor remains connected to the mains supply, the battery recharges automatically; when it is disconnected, moved or in the event of a power failure, it immediately takes over powering the display, the monitoring electronics, the measurement modules (ECG, SpO2, non-invasive blood pressure and temperature) and the alarms, without interrupting patient monitoring.

This pack uses lithium-ion (Li-ion) chemistry, with a nominal voltage of 11.1V and a capacity of 4.6Ah (51Wh), in a compact format of 181 x 23 x 60 mm and approximately 0.372 kg. Li-ion chemistry offers high energy density, virtually no memory effect and low self-discharge, making it ideal for equipment that alternates between mains and portable use. When battery life is noticeably reduced or the monitor warns of low battery prematurely, it is time to replace the battery with this reference.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) 88888111
Original manufacturer reference 115-018015-00 (Mindray)
Other part numbers of the same pack LI23S003A, 115-018011-00, 0146-00-0099, 0146-00-0069, 9201-30-35944, M05-010001-06
GUDID registration (UDI-DI) 06944904040219, identified as a lithium-ion battery pack 11.1V / 4600mAh, model LI23S003A
Technology Lithium-ion (Li-Ion), rechargeable
Nominal voltage 11.1 V
Capacity 4.6 Ah (4600 mAh)
Energy 51 Wh
Dimensions 181 x 23 x 60 mm
Weight Approximately 0.372 kg
Application Mindray vital signs monitors Accutorr+, Accutorr V, Passport 2, Passport V, Passport 3L, PM7000, PM8000, PM9000, Spectrum, Spectrum OR, Trio, DPM3, DPM4, DPM5, iPM9800, VS-800 and Datascope Ex family
Rechargeable Yes; automatic charging with the monitor connected to the mains
Professional use Power supply for vital signs monitors in hospital, emergency, ICU, operating theatre and intrahospital transport
Presentation 1 unit
Recycling Management in accordance with WEEE regulations

Note: the dimensions, weight and capacity correspond to the original pack 115-018015-00; as this is a replacement part, it is recommended to check the reference printed on the removed battery before replacement.

4. Equivalences and Cross-References

The original reference 115-018015-00 corresponds to the 11.1V lithium-ion battery pack that Mindray fits in the Accutorr+, Accutorr V, Passport, Spectrum, Trio, DPM and PM monitors, and is registered in GUDID. In specialist distribution, the original codes 115-018011-00, 0146-00-0099, 0146-00-0069, 9201-30-35944, M05-010001-06 and LI23S003A consistently appear as interchangeable part numbers for the same pack. The third-party alternatives listed below share the same chemistry (Li-ion), voltage (11.1V) and capacity window (4.6-5.2Ah) and are classified as comparable by category, not 1:1 interchangeable: they require verification of the connector, compartment dimensions and the equipment’s charging protocol before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cameron Sino Medical Series (Mindray Accutorr / Passport / Spectrum / Trio) CS-MPM700MD Comparable by category (not interchangeable 1:1) Li-ion 11.1V / 5200mAh (~57.7Wh), consistently documented as a replacement for 115-018015-00, 115-018011-00, 0146-00-0099, 9201-30-35944 and M05-010001-06 for Accutorr V, DPM3/4/5, iPM9800, Passport 2, Passport V, PM7000, Spectrum, Spectrum OR and Trio. Higher capacity (5.2Ah vs 4.6Ah); check pack dimensions and connector.
R&D Batteries 6132 Series (Mindray / Datascope) 6132-A / 6132-A-I (insert) Comparable by category (not interchangeable 1:1) Li-ion 11.1V / 5.2Ah (57.72Wh) stated as a replacement for 115-018011-00, M05-010001-06, 0146-00-0099 and 0146-00-0069 for the Accutorr Plus, Accutorr V, Passport, Spectrum, Spectrum OR, Trio and VS-800 platforms. Higher capacity; confirm housing and connection.
OSI Batteries (Unipower) Biomedical batteries for Mindray / Datascope monitors B12113 / B11641 / B11660 Comparable by category (not interchangeable 1:1) Cross references for the 11.1V Li-ion Accutorr/Passport/Spectrum/Trio pack cited in specialist distribution tables. Confirm capacity, connector and order dimensions before replacing.
Alpha Source OEM replacement for medical monitors AS30278 Comparable by category (not interchangeable 1:1) Cross reference for the 11.1V Li-ion pack cited in specialist distribution tables for the Mindray / Datascope Accutorr family. Verify batch specifications before ordering.
Interstate Batteries Biomedical range for vital signs monitors MED1248 Comparable by category (not interchangeable 1:1) Cross reference for the 11.1V Li-ion pack cited in specialist distribution tables. Check connector, capacity and dimensions against the specific equipment.

There is no equivalence table validated by the manufacturer (Mindray) that authorises third-party batteries for reference 115-018015-00; consult the technical department before using in a tender. Before a replacement, the following must be verified one by one: voltage (11.1V), chemistry (Li-ion), capacity, compartment dimensions and the equipment connector.

5. Selection tips and variants of interest

  • Identify the equipment and the reference: confirm on the label of the removed battery the code 115-018015-00 (or its alternative numbers 115-018011-00, 0146-00-0099, 0146-00-0069, 9201-30-35944, M05-010001-06, LI23S003A) before ordering the replacement.
  • Respect voltage and chemistry: the monitor is configured for lithium-ion at 11.1V. Do not install batteries of a different chemistry (Ni-MH, lead) or a different voltage, even if the compartment may appear similar.
  • Replace upon signs of wear: clearly reduced autonomy or low-battery warnings within a few hours of charging indicate that the accumulator has reached the end of its service life.
  • After the change: leave the monitor connected to the mains to complete the charge and check the battery indicator before returning the equipment to the clinical service.
  • Place orders by reference: always indicate the Cahnos code 88888111 or the original reference 115-018015-00 to avoid confusion with other batteries in the Mindray family.
  • Do not confuse with other variants: in the Cahnos catalogue you will find the Mindray batteries 115-018012-00 (BeneView T5/T8, Ref. 88888838), 115-018016-00 (BeneView T1, Ref. 88881063) and 115-007858-00 (BeneHeart D3, Ref. 88888837), which belong to other platforms and are not interchangeable 1:1 with the one for Accutorr+.
  • For mixed fleets and tenders: consult our catalogue of batteries for vital signs monitors (Mindray, Philips, GE Healthcare, Spacelabs, Nihon Kohden, CAS Medical and others) or contact our technical-commercial department to confirm compatibility and volume conditions.

Additional information

Battery type

Lithium-ion (Li-ion), rechargeable

Nominal voltage

11.1 V

Capacity

4.6 Ah (4600 mAh)

Energy

51 Wh

Manufacturer reference

115-018015-00 (Mindray)

Other original references

LI23S003A, 115-018011-00, 0146-00-0099, 0146-00-0069, 9201-30-35944, M05-010001-06

GUDID registration

UDI-DI 06944904040219 (Li-ion pack 11.1V / 4600mAh, model LI23S003A)

Dimensions

181 x 23 x 60 mm

Weight

Approximately 0.372 kg

Rechargeable

Yes; automatic charging with the monitor connected to the mains

Compatibility

Mindray Accutorr+, Accutorr V, Passport 2, Passport V, Passport 3L, PM7000, PM8000, PM9000, Spectrum, Spectrum OR, Trio, DPM3, DPM4, DPM5, iPM9800, VS-800 and Datascope Ex family

Use

Power supply for vital signs monitors in hospital, emergency, ICU, operating theatre and intrahospital transport

Recycling

Management in accordance with WEEE regulations

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Li-ion Battery 11.1V 4.6Ah for Mindray Accutorr+ Vital Signs Monitor | Original Ref. 115-018015-00 | Ref. Cahnos 88888111”

Your email address will not be published. Required fields are marked *