Description
1. Reliable power for your vital signs monitor
Keep your vital signs monitor always operational with this rechargeable lithium-ion battery of 11.1V and 4.6Ah, corresponding to the original reference 115-018015-00 from Mindray (Ref. Cahnos 88888111). It is the recommended replacement for the Accutorr+ monitor and the rest of the manufacturer’s compatible platforms: a technically proven, ready-to-install spare part that restores the equipment’s full autonomy in emergency departments, hospital wards, ICU, operating theatre and intra-hospital transport.
Designed for medical electronics departments, biomedical engineering and hospital purchasing, it is a reliable and very cost-effective solution compared with the official replacement, without compromising the safety required for continuous patient monitoring. It is supplied per unit for direct installation in the equipment’s battery compartment.
2. Technical explanation: how this battery works
The vital signs monitors in the Mindray Accutorr (Accutorr+, Accutorr V), Passport, Spectrum, Trio and DPM families incorporate an internal rechargeable battery that acts as a backup and portable power source. While the monitor remains connected to the mains supply, the battery recharges automatically; when it is disconnected, moved or in the event of a power failure, it immediately takes over powering the display, the monitoring electronics, the measurement modules (ECG, SpO2, non-invasive blood pressure and temperature) and the alarms, without interrupting patient monitoring.
This pack uses lithium-ion (Li-ion) chemistry, with a nominal voltage of 11.1V and a capacity of 4.6Ah (51Wh), in a compact format of 181 x 23 x 60 mm and approximately 0.372 kg. Li-ion chemistry offers high energy density, virtually no memory effect and low self-discharge, making it ideal for equipment that alternates between mains and portable use. When battery life is noticeably reduced or the monitor warns of low battery prematurely, it is time to replace the battery with this reference.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888111 |
| Original manufacturer reference | 115-018015-00 (Mindray) |
| Other part numbers of the same pack | LI23S003A, 115-018011-00, 0146-00-0099, 0146-00-0069, 9201-30-35944, M05-010001-06 |
| GUDID registration (UDI-DI) | 06944904040219, identified as a lithium-ion battery pack 11.1V / 4600mAh, model LI23S003A |
| Technology | Lithium-ion (Li-Ion), rechargeable |
| Nominal voltage | 11.1 V |
| Capacity | 4.6 Ah (4600 mAh) |
| Energy | 51 Wh |
| Dimensions | 181 x 23 x 60 mm |
| Weight | Approximately 0.372 kg |
| Application | Mindray vital signs monitors Accutorr+, Accutorr V, Passport 2, Passport V, Passport 3L, PM7000, PM8000, PM9000, Spectrum, Spectrum OR, Trio, DPM3, DPM4, DPM5, iPM9800, VS-800 and Datascope Ex family |
| Rechargeable | Yes; automatic charging with the monitor connected to the mains |
| Professional use | Power supply for vital signs monitors in hospital, emergency, ICU, operating theatre and intrahospital transport |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations |
Note: the dimensions, weight and capacity correspond to the original pack 115-018015-00; as this is a replacement part, it is recommended to check the reference printed on the removed battery before replacement.
4. Equivalences and Cross-References
The original reference 115-018015-00 corresponds to the 11.1V lithium-ion battery pack that Mindray fits in the Accutorr+, Accutorr V, Passport, Spectrum, Trio, DPM and PM monitors, and is registered in GUDID. In specialist distribution, the original codes 115-018011-00, 0146-00-0099, 0146-00-0069, 9201-30-35944, M05-010001-06 and LI23S003A consistently appear as interchangeable part numbers for the same pack. The third-party alternatives listed below share the same chemistry (Li-ion), voltage (11.1V) and capacity window (4.6-5.2Ah) and are classified as comparable by category, not 1:1 interchangeable: they require verification of the connector, compartment dimensions and the equipment’s charging protocol before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cameron Sino | Medical Series (Mindray Accutorr / Passport / Spectrum / Trio) | CS-MPM700MD | Comparable by category (not interchangeable 1:1) | Li-ion 11.1V / 5200mAh (~57.7Wh), consistently documented as a replacement for 115-018015-00, 115-018011-00, 0146-00-0099, 9201-30-35944 and M05-010001-06 for Accutorr V, DPM3/4/5, iPM9800, Passport 2, Passport V, PM7000, Spectrum, Spectrum OR and Trio. Higher capacity (5.2Ah vs 4.6Ah); check pack dimensions and connector. |
| R&D Batteries | 6132 Series (Mindray / Datascope) | 6132-A / 6132-A-I (insert) | Comparable by category (not interchangeable 1:1) | Li-ion 11.1V / 5.2Ah (57.72Wh) stated as a replacement for 115-018011-00, M05-010001-06, 0146-00-0099 and 0146-00-0069 for the Accutorr Plus, Accutorr V, Passport, Spectrum, Spectrum OR, Trio and VS-800 platforms. Higher capacity; confirm housing and connection. |
| OSI Batteries (Unipower) | Biomedical batteries for Mindray / Datascope monitors | B12113 / B11641 / B11660 | Comparable by category (not interchangeable 1:1) | Cross references for the 11.1V Li-ion Accutorr/Passport/Spectrum/Trio pack cited in specialist distribution tables. Confirm capacity, connector and order dimensions before replacing. |
| Alpha Source | OEM replacement for medical monitors | AS30278 | Comparable by category (not interchangeable 1:1) | Cross reference for the 11.1V Li-ion pack cited in specialist distribution tables for the Mindray / Datascope Accutorr family. Verify batch specifications before ordering. |
| Interstate Batteries | Biomedical range for vital signs monitors | MED1248 | Comparable by category (not interchangeable 1:1) | Cross reference for the 11.1V Li-ion pack cited in specialist distribution tables. Check connector, capacity and dimensions against the specific equipment. |
There is no equivalence table validated by the manufacturer (Mindray) that authorises third-party batteries for reference 115-018015-00; consult the technical department before using in a tender. Before a replacement, the following must be verified one by one: voltage (11.1V), chemistry (Li-ion), capacity, compartment dimensions and the equipment connector.
5. Selection tips and variants of interest
- Identify the equipment and the reference: confirm on the label of the removed battery the code 115-018015-00 (or its alternative numbers 115-018011-00, 0146-00-0099, 0146-00-0069, 9201-30-35944, M05-010001-06, LI23S003A) before ordering the replacement.
- Respect voltage and chemistry: the monitor is configured for lithium-ion at 11.1V. Do not install batteries of a different chemistry (Ni-MH, lead) or a different voltage, even if the compartment may appear similar.
- Replace upon signs of wear: clearly reduced autonomy or low-battery warnings within a few hours of charging indicate that the accumulator has reached the end of its service life.
- After the change: leave the monitor connected to the mains to complete the charge and check the battery indicator before returning the equipment to the clinical service.
- Place orders by reference: always indicate the Cahnos code 88888111 or the original reference 115-018015-00 to avoid confusion with other batteries in the Mindray family.
- Do not confuse with other variants: in the Cahnos catalogue you will find the Mindray batteries 115-018012-00 (BeneView T5/T8, Ref. 88888838), 115-018016-00 (BeneView T1, Ref. 88881063) and 115-007858-00 (BeneHeart D3, Ref. 88888837), which belong to other platforms and are not interchangeable 1:1 with the one for Accutorr+.
- For mixed fleets and tenders: consult our catalogue of batteries for vital signs monitors (Mindray, Philips, GE Healthcare, Spacelabs, Nihon Kohden, CAS Medical and others) or contact our technical-commercial department to confirm compatibility and volume conditions.