We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Original GE Healthcare Li-ion Battery 7.2 V 2.25 Ah for MAC 400 Electrocardiograph · Replaces Ref. 2047357-001 (MAC 600 / MAC C3) | Code Cahnos 88888594

104,00 €

Original lithium-ion battery of 7.2 V and 2.25 Ah for the GE Healthcare MAC 400 electrocardiograph, corresponding to manufacturer reference 2047357-001 (code Cahnos 88888594). High-quality replacement that restores the device’s full battery life for electrocardiographic recording in outpatient consultations, emergency departments and hospitalisation, with automatic recharging while the device remains connected to the mains. It also replaces references 2030912-001 and 2073265-001 and is documented for the MAC 600 and MAC C3 models of the same family. Direct installation in the battery compartment, without tools or adaptations, with management of the replacement in accordance with WEEE regulations.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0159018

Description

1. Commercial Introduction

At Cahnos we make available to you the original 7.2 V and 2.25 Ah lithium-ion battery for the GE Healthcare MAC 400 electrocardiograph (manufacturer ref. 2047357-001, Cahnos code 88888594). It is the replacement that keeps your electrocardiographic diagnostic equipment operational when working in battery mode: recording of resting ECG without depending on the mains power supply, both in the consulting room and on hospital wards, emergency departments and intra-hospital transport. Available with delivery in 24/72 h for cardiology departments, ECG clinics and medical electronics maintenance programmes, and with replacement management in accordance with WEEE regulations.

2. Technical Explanation

The electrocardiographs of the GE Healthcare MAC 400 family (formerly the Marquette / GE Medical line) incorporate an internal rechargeable battery that powers the device when it is disconnected from the mains power supply. While the electrocardiograph remains connected to the mains, the battery remains on charge; if the supply fails or the device is moved to attend to the patient, the battery automatically takes over the power supply without interrupting the electrocardiographic examination.

This replacement is a rechargeable lithium-ion (Li-ion) battery that delivers a nominal voltage of 7.2 V and a capacity of 2.25 Ah (2,250 mAh, ≈16.2 Wh), enough energy to maintain the electrocardiographic recording, the screen and the thermal printer during scheduled examinations. Li-ion chemistry offers high energy density, low self-discharge and a stable discharge curve, with a longer cycle life than nickel technologies. It is housed in the specific compartment of the device and its replacement is carried out directly, without tools or adaptations. Before fitting it, confirm the reference marked on the original battery (2047357-001 or other part numbers for the same battery).

3. Technical Specifications

Data verified against the product technical data sheet (code 88888594) and the specifications of the original GE Healthcare manufacturer reference.

Parameter Specification
Product type Rechargeable internal battery for electrocardiograph (original brand)
Reference Cahnos (SKU) 0159018 / 88888594
Manufacturer reference 2047357-001 (GE Healthcare)
Technology / Chemistry Li-ion (lithium-ion), rechargeable
Nominal voltage 7.2 V
Nominal capacity 2.25 Ah (2,250 mAh)
Approximate energy ≈16.2 Wh (7.2 V × 2.25 Ah)
Approximate weight 0.343 kg (according to distribution technical data sheet)
Recharge Automatic with the electrocardiograph connected to the mains supply
Installation Direct replacement in the equipment battery compartment, without tools
Intended use Recording and interpretation of 12-lead ECG in cardiology, emergency and hospitalisation
Presentation 1 unit
Recycling Management in accordance with WEEE regulations

Documented compatibility:

Equipment Original GE references it replaces
GE Healthcare MAC 400 2047357-001
GE Healthcare MAC 600 2030912-001 (also 2047357-001)
GE Healthcare MAC C3 2047357-001 / 2073265-001

4. Equivalences and Cross-References

Notice about the code: the reference 2047357-001 is the original part of the device and appears consistently in authorised distribution sources. The product technical data sheet (code 88888594) also documents the alternative part numbers 2030912-001, 2024423-001, 2111132-001 and 2111133-001 as original references for the same battery, and authorised industry listings associate the family with the MAC 400, MAC 600 and MAC C3 models. GE Healthcare does not publish an official cross-reference table with third-party batteries; the following cross-references share chemistry and functionality, but must be validated field by field before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GE Healthcare (alternative part numbers for the same battery) Original battery MAC 400 / MAC 600 / MAC C3 (Li-ion 7.2 V) 2030912-001, 2073265-001, 2024423-001, 2111132-001, 2111133-001 Comparable by category (not interchangeable 1:1) Alternative part numbers for the same original battery documented in the distribution technical data sheet (code 88888594) and in authorised listings; same voltage and Li-ion chemistry. Confirm the device batch label before ordering.
Cameron Sino Replacement battery for GE MAC 400 / MAC 600 / MAC C3 CS-GMC400MD Comparable by category (not interchangeable 1:1) Li-ion 7.4 V / 2,200 mAh, built to replace 2030912-001, 2047357-001 and 2073265-001; voltage and capacity slightly different from the original (7.2 V / 2.25 Ah). Verify the charging electronics, connector and fit in the compartment.
Kingsener Replacement battery 2047357-001 for GE MAC 400 / MAC C3 / MAC 600 2047357-001 (Kingsener listing) Comparable by category (not interchangeable 1:1) Li-ion 7.4 V / 2,200 mAh declared, replaces 2030912-001 and 2073265-001. Third-party construction with lower capacity than the original; confirm chemistry and connector of the received batch.
Energystox Replacement battery for GE EKG MAC 400 / MAC 600 EX-L261 Comparable by category (not interchangeable 1:1) Li-ion 7.4 V / 2,200 mAh declared for the same references 2030912-001, 2047357-001 and 2073265-001. Aftermarket construction; validate dimensions and connector type against the specific device.

There is no equivalence table validated by the device manufacturer (GE Healthcare) that cross-references this part with third-party batteries; the indicated references have been verified against battery manufacturer catalogues and authorised distribution, but the 1:1 replacement must be validated field by field (voltage, chemistry, capacity, pack dimensions and connector) against the specific device. Consult the technical department before use in tendering.

5. Selection tips and variants of interest

  • Check the exact device model: this 7.2 V / 2.25 Ah battery is the one indicated for the GE Healthcare MAC 400 and is also documented for the MAC 600 and MAC C3 of the same family (source: authorised distribution). Do not install it in other models of the MAC family that use different batteries, such as the MAC 5000 (18 V / 3.5 Ah, Ref. Cahnos 88888228), the MAC PC (19.2 V, Ref. 88888221), the MAC 2000 (14.4 V Li-ion, Ref. 88881342) or the MAC 800 (7.2 V / 4.5 Ah, Ref. 0159045).
  • Confirm the stamped reference: if the removed battery shows the code 2047357-001, 2030912-001, 2073265-001, 2024423-001 or 2111132-001, it may be the original rechargeable battery that this replacement replaces; contact our technical-commercial department to confirm before placing the order.
  • Replace on signs of wear: clearly reduced battery life, premature low-battery warnings or excessive charging times indicate that the Li-ion rechargeable battery has reached the end of its useful life.
  • After replacement: leave the device connected to the mains to complete a charging cycle and check that the battery indicator reflects the new status before returning it to service.
  • Environmental management: take the exhausted battery to a specialised collection point (WEEE); do not place it in the general waste container.
  • Fleet and tender purchases: for fleets of electrocardiographs, maintenance contracts or public tenders, request special conditions, availability and documentation (declaration of conformity and safety data sheet) from our technical-commercial team.

Additional information

Product type

Rechargeable internal battery for electrocardiograph (original brand)

Manufacturer reference

2047357-001 (GE Healthcare); alternative part numbers for the same battery: 2030912-001, 2073265-001, 2024423-001, 2111132-001, 2111133-001

Technology

Li-ion (lithium-ion), rechargeable

Nominal voltage

7.2 V

Nominal capacity

2.25 Ah (2,250 mAh)

Energy

≈16.2 Wh (7.2 V × 2.25 Ah)

Approximate weight

0.343 kg

Rechargeable

Yes (automatic recharging with the device connected to the mains)

Compatibility

GE Healthcare MAC 400; also documented for MAC 600 and MAC C3 (Marquette / GE Medical family)

Application

Recording and interpretation of 12-lead ECG in cardiology, emergency and hospitalisation

Recycling

RAEE/WEEE

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Original GE Healthcare Li-ion Battery 7.2 V 2.25 Ah for MAC 400 Electrocardiograph · Replaces Ref. 2047357-001 (MAC 600 / MAC C3) | Code Cahnos 88888594”

Your email address will not be published. Required fields are marked *