Description
1. Reliable power for your GE Dinamap Pro 1000 monitor
At Cahnos we offer you the replacement battery for the vital signs monitor GE Dinamap Pro 1000 (Ref. Cahnos 88888107), corresponding to the original manufacturer’s reference 2014833-001. This is a high-capacity nickel-metal hydride (Ni-MH) rechargeable battery, maintenance-free and with a very low memory effect, which restores full autonomy to the device for continuous monitoring of non-invasive blood pressure (NIBP) and other parameters in outpatient clinics, hospital wards, emergency, ICU and intra-hospital transport.
It is the ideal solution for biomedical engineering services, medical electronics maintenance and hospital purchasing departments seeking a traceable spare part of proven quality at a very competitive cost compared to the official replacement, without compromising the reliability required for patient monitoring.
2. Technical explanation: how this battery works
The GE Dinamap Pro 1000 is a bedside and transport vital signs monitor widely used in clinical settings, specialised in non-invasive blood pressure measurement by oscillometric method and commonly used in surgery, emergency and critical care. To ensure patient monitoring when the device is not connected to the mains, it incorporates a rechargeable internal battery that acts as a backup power source: while the monitor remains plugged in, the battery recharges automatically; when the device is disconnected, moved or during a power cut, the battery takes over powering the control electronics, the cuff inflation pump, the display and the alarms, without interrupting monitoring.
This battery uses Ni-MH (nickel-metal hydride) chemistry, cadmium-free and with a very low memory effect, with a nominal voltage of 12 V and a capacity of 7.6 Ah (≈91.2 Wh). When autonomy noticeably decreases or the monitor warns of low battery prematurely, it is time to replace the battery with this reference. Its installation is direct in the device’s original compartment, without the need for tools or adaptations.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | 88888107 |
| Original manufacturer reference (OEM) | 2014833-001 |
| Other documented original part numbers | 633177, MS633177C, MS633177K, 0250861, B11187, M1943, Y10SSC2000 |
| Accumulator type | Ni-MH (nickel-metal hydride), rechargeable, maintenance-free |
| Nominal voltage | 12 V (the commercial datasheet states 2X12V pack configuration) |
| Nominal capacity | 7.6 Ah (7,600 mAh) |
| Theoretical energy | ≈ 91.2 Wh (12 V × 7.6 Ah) |
| Chemistry | Ni-MH, cadmium-free, very low memory effect |
| Recharge | Automatic with the monitor connected to the mains |
| Application | GE Dinamap Pro 1000 (V3) vital signs monitor |
| Documented market compatibility | Dinamap Pro 1000 / 1006 / 1008 / 1009; Critikon Compact T, Pro 100 / 200 / 300 / 400 and Procare NIBP100 (verify lot) |
| Indicative dimensions of the compatible pack | ≈ 135.3 × 84.6 × 33.7 mm (cross-check with the installed part) |
| Approximate weight | ≈ 0.93 kg |
| Presentation | 1 unit |
Note: the dimensions and weight indicated correspond to the reference compatible pack documented in the spare parts market; as this is a replacement part, it is recommended to cross-check dimensions, connector and cell configuration with the original battery before replacement.
4. Equivalences and Cross-References
Ref. Cahnos 88888107 corresponds to the 12 V / 7.6 Ah Ni-MH battery that replaces the original part numbers of the device 2014833-001 (battery pack and holder for Dinamap Pro 1000 V3) and its variants 633177, MS633177C, 0250861, B11187, M1943 and Y10SSC2000, codes that consistently appear in multiple independent distribution sources linked to Dinamap Pro 1000/1006/1008/1009 monitors and the Critikon family. GE Healthcare does not publish an official equivalence table authorising third-party batteries for this reference; the alternatives listed below share chemistry (Ni-MH), voltage (12 V) and capacity window and are classified as comparable by category, not 1:1 interchangeable, and connector, dimensions and housing must be verified before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cameron Sino | Medical Series (GE / Critikon) | CS-GMP100MD | Comparable by category (not interchangeable 1:1) | Ni-MH 12 V / 7,600 mAh (91.2 Wh), ≈135.3 × 84.6 × 33.7 mm, ≈0.93 kg; declared as a replacement for 2014833-001, MS633177C, B11187, 0250861 and Y10SSC2000 for Dinamap Pro 1000/1006/1008/1009 and Critikon Compact T / Pro. Same chemistry, voltage and capacity; verify connector and compartment. Manufacturer/distributor datasheet consulted. |
| R&D Batteries | Series 5106 (insert) | 5106-I | Comparable by category (not interchangeable 1:1) | Ni-MH 12 V / 8.0 Ah, insert for Dinamap Pro 1000/1100; crosses with 633177, MS633177C and 2014833-001. Higher capacity (8 Ah vs 7.6 Ah) and insert format; check housing and connection. Specialist distributor data sheet consulted. |
There is no equivalence table validated by GE Healthcare that cross-references reference 2014833-001 with third-party brands; the alternatives listed are comparable by category and must be checked against the technical data sheet and the equipment manual before use. Consult the technical department before using this reference in tenders.
5. Selection tips and variants of interest
- Identify the exact monitor: this 12 V / 7.6 Ah battery is the one indicated for the GE Dinamap Pro 1000 (V3) family. Do not confuse it with batteries from other vital signs monitors of different voltage or chemistry, even if the compartment may look similar.
- Check the reference of the fitted battery: check the codes 2014833-001, 633177, MS633177C or other numbering on the battery label before replacing. Always respect the voltage (12 V) and the Ni-MH chemistry; do not use batteries of another chemistry or voltage without validation from the technical service.
- Replace when signs of wear appear: clearly reduced battery life or low-battery warnings a few hours after charging indicate that the battery has reached the end of its service life.
- After replacement: leave the monitor connected to the mains to complete the charge and check that the battery indicator reflects the new status before returning the equipment to clinical service.
- Ordering by reference: always quote code 88888107 or the original equipment reference (2014833-001 / 633177) to avoid confusion with other batteries in the Dinamap family.
- For mixed fleets: consult our catalogue of batteries for vital signs monitors; we stock spare parts for the GE Healthcare, Philips, Spacelabs, Mindray, Nihon Kohden, CAS Medical and other families.
If in any doubt, contact our technical-commercial department stating the model, serial number and reference of the fitted battery; we will confirm compatibility before finalising the order.