12V 2.3Ah SLA Battery for Hamilton Raphael Ventilator (369086) – Respiratory and Ventilation Replacement | Ref. 88889715

16,00 €

Sealed lead-acid (SLA/VRLA) battery of 12V and 2.3Ah for the Hamilton Raphael ventilator (model 369086). Rechargeable, leak-proof and maintenance-free replacement, designed to ensure the ventilator’s autonomy during intra-hospital transport and in the event of mains power failure. Cell format 178 x 34 x 64 mm with Faston F1 terminals and approximate weight of 0.94 kg. Catalogue reference 88889715; confirm equipment model and connector type before replacement.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88889715

Description

Backup battery for your Hamilton Raphael

Ensure the continuous operation of your Hamilton Raphael ventilator with this internal battery of 12V 2.3Ah in sealed lead-acid technology (SLA/VRLA). It is the recommended spare part to maintain mechanical ventilation during intrahospital transfers, in emergencies, or when a power supply interruption occurs. Catalogue reference 88889715.

What this battery is and how it works

The Hamilton Raphael ventilator (model 369086) is a compact ventilator designed for ICU and transport. It incorporates an internal sealed lead-acid battery that acts as a backup power source: while the equipment is connected to the mains, the battery remains on float charge; when the equipment is disconnected to transfer the patient or in the event of a mains failure, it automatically takes over power without interrupting ventilation.

This cell uses VRLA/AGM technology (valve-regulated, with gas recombination and electrolyte absorbed in fibreglass mat): it is completely sealed, requires no maintenance, does not spill liquid and can be installed in any position within the equipment compartment. Faston F1 terminals (4.75 mm) ensure a firm connection with the ventilator’s management electronics. After replacing the cell, it is advisable to let the equipment complete its power-on self-test and carry out a full charge and discharge cycle so that the system recalibrates the capacity thresholds.

Technical specifications

Parameter Value
Nominal voltage 12 V
Nominal capacity 2.3 Ah (base cell 2.1 Ah in NP2.1-12 format)
Energy 27.6 Wh
Technology Sealed lead-acid, VRLA/AGM, maintenance-free
Cell dimensions 178 x 34 x 64 mm (height up to 66 mm over terminals)
Approximate weight 0.94 kg (0.95–0.97 kg depending on cell)
Terminals Faston F1 (4.75 mm)
Application Hamilton Raphael Ventilator (model 369086)
Terms of use Sealed and non-spillable (UN2800); installable in any position

Reference data

Field Value
Catalogue reference Cahnos 88889715
Compatible equipment Hamilton Raphael Ventilator (model 369086)
Equipment manufacturer Hamilton Medical
Spare part type Internal sealed lead-acid battery, premium generic quality

Equivalences and cross-references

The reference 88889715 is the catalogue coding of the European distributor/assembler of the generic spare part; it is not an OEM code from Hamilton Medical, which does not publish an official cross-reference table for this cell. The battery corresponds to a standard sealed lead-acid cell 12V 2.3Ah in format 178 x 34 x 64 mm (family of Yuasa NP2.3-12 / NP2.1-12), which is the base documented by the spare part assembler and verified in the official technical data sheet of GS Yuasa. The cross-references indicated below share chemistry, voltage, capacity and dimensions, and are considered comparable at category level; connector and orientation must be verified before assembly.

Cell manufacturer Family / Model Code / SKU Equivalence level Technical differences / Remarks
GS Yuasa NP series (standby and cyclic) NP2.3-12 / NP2.3-12FR Comparable by category (not interchangeable 1:1) Standard cell 12V 2.3Ah, 178 x 34 x 64 mm, 0.95 kg, Faston 4.75 mm terminal (F1). Verified in GS Yuasa official datasheet and cited as a direct cross for the Hamilton 369086 in tables from several authorised distributors.
GS Yuasa NP series (standby and cyclic) NP2.1-12 Comparable by category (not interchangeable 1:1) 12V, 2.1Ah nominal (20h rate), same housing 178 x 34 x 64 mm and Faston F1. Slightly lower capacity; it is the base cell format cited by the European spare part assembler (weight 0.97 kg).
Leoch LP series (general use) LP12-2.3 Comparable by category (not interchangeable 1:1) 12V 2.3Ah SLA/VRLA cited in distributor datasheets as a cross for the Hamilton 369086 and other 12V 2.3Ah medical equipment. Verify terminals and housing before assembly.

As support, the cross-reference tables published by medical battery distributors also cite the references NCE NP2.3-12FR, Interstate SLA1015, MK Battery BMED00317, Alpha Source AS00221/AS00317, OSI B00317 and Anybattery 5348 for the Hamilton 369086; these codings come from repackagers and must be confirmed with the cell manufacturer before use.

There is no equivalence table validated by the manufacturer (Hamilton Medical); consult the technical department before use in tenders.

Selection tips and variants of interest

  • Identify the equipment: this battery corresponds to the Hamilton Raphael ventilator, model 369086. Confirm the model and the label of the mounted battery (12V, sealed lead) before replacing.
  • Do not confuse it with other chemistries: the Hamilton C2/C3/C6/S1 series use lithium-ion batteries (ref. 369106, 14.4V), and the T1/C1/MR1 series use 10.8V lithium (ref. 369108). In our catalogue you will find: Hamilton C2 Li-Ion Battery (Ref. 88889247) and Hamilton T1 Li-Ion Battery (Ref. 88881134).
  • Same cell in other equipment: the 12V 2.3Ah SLA cell is also used in ventilators such as the GE Datex Aestiva 7000 (Ref. 88888128) and in other lines of the Yuasa cell catalogue (Refs. Cahnos 33101010 and 33101011 for the 2.1Ah and 2.3Ah formats).
  • After replacement: charge the battery before first use and let the ventilator complete the power-on self-test without interruptions; a full charge and discharge cycle helps recalibrate the low battery threshold.
  • Storage: avoid prolonged deep discharges and keep the battery in a cool, dry place; if stored, it is recommended to recharge it periodically to avoid falling below the equipment’s recovery threshold.
  • If you have any queries, please contact our technical department, quoting the model, serial number and reference of the fitted battery; we will confirm compatibility before you place your order.

Additional information

Nominal voltage

12 V

Capacity

2.3 Ah (base cell 2.1 Ah, format NP2.1-12)

Energy

27.6 Wh

Technology

Sealed lead-acid VRLA/AGM (SLA), maintenance-free

Dimensions

178 x 34 x 64 mm (up to 66 mm with terminals)

Weight

Approx. 0.94 kg (0.95–0.97 kg depending on cell)

Terminals

Faston F1 (4.75 mm)

Application

Hamilton Raphael Ventilator (model 369086)

Equipment manufacturer

Hamilton Medical

Maintenance

Maintenance-free; sealed and non-spillable (UN2800)

Catalogue reference

88889715