Description
1. Replacement battery for your Liko Hill-Rom Viking lift
This replacement battery is designed for Liko Hill-Rom Viking patient lifting systems with 4-point connector, one of the most widely used mobile lifts in hospitals, geriatric nursing homes and rehabilitation units. By replacing the exhausted accumulator with this nickel-metal hydride (Ni-MH) pack, the lift recovers its operating autonomy without needing to modify the charger, electronics or wiring: it is a direct spare part intended for fleets of lifts in continuous use.
2. How this battery works in the patient lift
The Viking lift enables safe patient transfers between bed, wheelchair, hoist and floor, reducing the strain on healthcare staff. When the equipment is not connected to the mains (transfers between rooms, transfer manoeuvres or in the event of a power cut), the internal battery powers the control system and the lifting actuators. For this reason, the charge status and correct sizing of the accumulator are critical: a depleted battery or one with unsuitable chemistry can leave the lift without rescue function.
Ni-MH chemistry offers stable current delivery, reduced memory effect and good resistance to repeated charge-discharge cycles, essential characteristics in equipment for continuous healthcare use. The 4-point connector ensures firm contact with the lift electronics and quick installation without specialised tools.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Application | Liko Hill-Rom Viking patient lifting system, 4-point connector |
| Reference | 88888857 (SKU 0159029) – Viking Conector 4 Puntos model |
| Technology | Ni-MH (nickel-metal hydride) rechargeable |
| Nominal voltage | 12 V |
| Capacity | 2.7 Ah |
| Energy | 32.4 Wh |
| Connector type | 4-point connector (4 pins) |
| Dimensions | 120 x 80 x 50 mm |
| Weight | Approximately 1.3 kg |
| Equipment manufacturer | Liko / Hill-Rom |
Note: before replacing, always compare the voltage, connector type and dimensions with the label of the removed battery; some Viking models mount two 12 V batteries in series.
4. Equivalences and Cross-References
The equipment manufacturer (Liko / Hill-Rom) does not publish an official third-party spare parts table for this battery. The reference 88888857 is documented in distribution sources as a spare part for Viking lifts, replacing the original reference 2006107 (Linak BAL 20001 family). The references verified in public sources and specialised distributors are listed below with their equivalence level.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Hill-Rom (equipment manufacturer) | Ni-MH battery for Viking M / Golvo 8008 lifts | 2006107 | Comparable by category (not interchangeable 1:1) | Original reference cited for the Viking (documented in UGAP as corresponding to 88888857); it is described on the market as a Ni-MH 24 V 2.7 Ah pack. Verify voltage with the label before ordering. |
| Linak (actuation platform) | BAL 20001 family (4 PTS variant) | BAL20001-02 / BAL20001-4PTS / CSA07033 | Comparable by category (not interchangeable 1:1) | Same family of Ni-MH packs used in Liko lifts with Linak actuator (Viking M, Golvo 8000/8008); the -02 variant is documented at 24 V 2.7 Ah. Confirm 4-pin connector and voltage. |
| Master Instruments | Medical battery for Linak/Liko patient lift | MB514M | Comparable by category (not interchangeable 1:1) | Ni-MH 24 V spare part designed for BAL 20001-01/02 variants; check connector and fit in the lift compartment. |
| Yucel | Standard 12 V series Y cell (SLA) | Y2.9-12 | Comparable by category (not interchangeable 1:1) | 12 V 2.9 Ah sealed lead-acid with F1 terminals, standard cell documented in some spare parts for the Viking series; different chemistry from Ni-MH. Verify terminal, size and charger before replacing. |
There is no equivalence table validated by the equipment manufacturer that cross-references the 88888857 reference with spare parts from other manufacturers; consult the technical department before using this reference in a tender or before replacing the original battery with a third-party spare part. The third-party references indicated are compatible spare parts verified by specialised distributors; compare voltage (12 V or 24 V), 4-point connector type, dimensions and chemistry with the removed battery.
5. Selection tips and variants of interest
- Verify the original battery reference: confirm on the label of the removed pack whether the Viking model designation or the Linak BAL 20001 family reference appears (e.g. 2006107 / BAL20001-02); different endings may correspond to different connectors or voltages.
- Check how many batteries you need: some models in the Viking series work with two 12 V batteries in series (24 V pack); check both units and replace them in pairs to maintain charge balance.
- Do not alter voltage or chemistry: always use Ni-MH packs of the nominal voltage indicated by the equipment manufacturer; increase capacity only if the lift charger allows it.
- Check the charge status periodically: if the lift loses autonomy, emits low battery alarms or manoeuvres become slow, replace the pack to avoid interruptions during patient transfer.
- Storage and recycling: if the lift is not used for long periods, store the battery with a partial charge (40-60 %) and avoid extreme temperatures; at the end of its useful life, take it to a recycling centre or an authorised WEEE/battery management operator.
For corporate orders, lift fleet maintenance or tender preparation, our technical-commercial team is available to confirm the exact compatibility with your lift before finalising the purchase.





Reviews