Original Arjo Marisa Battery NDA0100 24V 4Ah (96Wh) Ni-MH for Patient Lift | Original Brand Replacement | Ref. 88888718

352,00 €

Original Arjo Marisa battery NDA0100 (Ref. Cahnos 88888718): rechargeable battery of 24 V and 4 Ah (96 Wh) in Ni-MH technology, designed for the Arjo Marisa patient lift system. It restores the lift’s full autonomy in hospitals, care homes and social and healthcare centres, with direct replacement in the equipment compartment, without tools, and recharging via the lift’s own charger. Original, traceable medical spare part, of robust construction and suitable for medical electronics maintenance programmes, equipment fleets and volume institutional orders.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888718

Description

1. Original power for your Arjo Marisa hoist

Keep your Arjo Marisa patient lifting system operational with the original Arjo NDA0100 battery that we supply under reference Cahnos 88888718. This rechargeable battery of 24 V and 4 Ah (96 Wh) in Ni-MH technology restores full autonomy to the equipment for lifting, transferring and moving patients in hospitals, care homes, social health centres and home care, without relying on the mains power supply.

It is the original spare part solution for maintenance services, biomedical engineering and purchasing departments that need a traceable, proven-quality replacement to keep their fleet of Arjo hoists operational, with the guarantee provided by a component from the brand itself. Available with immediate delivery and special conditions for consortia, tenders and maintenance contracts.

2. How this battery works in the lifting system

The Arjo Marisa patient hoist powers its lifting motor via an internal rechargeable battery when the equipment is not connected to the mains. When autonomy drops noticeably, the hoist gives premature low battery warnings or lifting becomes slow, it is time to replace the battery with this 24 V / 4 Ah reference.

The Ni-MH (nickel-metal hydride) chemistry delivers the nominal 24 V required by the equipment from 1.2 V cells connected in series, offers a very low memory effect and contains no cadmium. Replacement is carried out by removing the depleted battery from the compartment and installing the new one respecting the orientation and connector, without the need for tools or adaptations. After installation, a full charge is recommended before first use.

Technical note: some old commercial datasheets describe the NDA0100 pack as Ni-MH of 1.2 kg with the dimensions indicated in this datasheet; however, the technical documentation from biomedical spare parts manufacturers and authorised distributors mostly identifies the pack that replaces the original NDA0100 reference as sealed lead-acid (SLA/VRLA AGM) of 24 V / 4 Ah, with an approximate weight of 3.99 kg and dimensions of 551 × 92 × 56 mm. Before replacing, check the label of the installed battery and the chemistry for which your equipment’s charger is set.

3. Technical Specifications

Characteristic Specification
Application Arjo Marisa patient lifting system (original reference NDA0100)
Original manufacturer reference Arjo NDA0100 (distribution sub-references: NDA0100-03, NDA0100-20, NDA0100-XX and HMX991)
Reference Cahnos (SKU) 88888718
Technology Ni-MH (nickel-metal hydride), rechargeable
Nominal voltage 24 V
Capacity 4 Ah (4000 mAh)
Energy 96 Wh (24 V × 4 Ah)
Weight Approximately 1.2 kg
Dimensions 150 × 80 × 70 mm
Device manufacturer Arjo
Rechargeable Yes; recharges with the hoist’s own charger
Installation Direct replacement in the lift compartment, without tools
Presentation 1 unit
Recycling Manage in accordance with WEEE regulations

Market version of the NDA0100 reference: the technical documentation from biomedical spare parts manufacturers mostly identifies the pack that replaces this original reference as sealed lead-acid (SLA/VRLA AGM) of 24 V / 4 Ah, with an approximate weight of 3.99 kg and dimensions of 551 × 92 × 56 mm. Always verify the chemistry for which your hoist’s charger is set.

4. Equivalences and Cross-References

The original Arjo NDA0100 reference (24 V / 4 Ah) has been cross-checked against biomedical battery manufacturers and specialised distribution catalogues. Arjo does not publish an official equivalence table authorising third-party batteries; the following references share the electrical platform (24 V, 4 Ah, sealed lead-acid AGM in its market version) and are classified as comparable by category, not 1:1 interchangeable, and must be validated field by field (voltage, chemistry, dimensions and connector) against the specific equipment before replacement.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
MSP Medical Battery pack 24V/DC 4Ah for Arjo patient hoists MSP-A-AH-00100 (EAN 8719925310003) Comparable by category (not interchangeable 1:1) SLA/VRLA AGM 24 V / 4 Ah; replaces NDA0100-03, NDA0100-20 and HMX991; MDR compliant; same voltage and capacity, verify connector and dimensions. Confirmed in the spare part manufacturer’s datasheet.
BBM Battery Biomedical pack No. 5050 for Arjo Marisa patient hoist 5050 Comparable by category (not interchangeable 1:1) SLA 24 V / 4 Ah; replaces NDA0100-XX, NDA0100-03, NDA0100-20 and HMX991; same electrical platform, check fit and connector. Confirmed in the spare part manufacturer’s datasheet.
ALCO / Direct Supply 24V battery for Arjo hoists (Marisa, Sara 3000, Minstrel, Walker, Calypso, Maxi Move 3, Maxi 500, Miranti, Bolero) AL-73743 Comparable by category (not interchangeable 1:1) 24 V / 4 Ah for the range of hoists with reference NDA0100; approximate charging time of 4 hours; verify fit and connector on the specific unit. Confirmed in the distributor’s datasheet.

In our own catalogue you also have the compatible version of this same reference (Ref. Cahnos 88881140, 24 V / 4 Ah in sealed lead-acid AGM) as a lower-cost alternative to the original replacement.

There is no equivalence table validated by the manufacturer Arjo for this reference; the cross-references indicated come from biomedical battery manufacturers and specialised distributors, so it is recommended to consult the technical department before use in tendering.

5. Selection tips and variants of interest

  • Confirm the exact equipment model: this 24 V / 4 Ah battery corresponds to the original Arjo reference NDA0100 for the Marisa lift. Check the numbering marked on the label of the depleted battery (NDA0100, NDA0100-03, NDA0100-20, NDA0100-XX or HMX991) before ordering.
  • Verify the batch chemistry: if your unit is fitted with a sealed lead-acid (AGM) pack, the charger is specific to that chemistry; do not install a battery of a different chemistry or voltage without prior technical validation, even if the connector may appear compatible.
  • Replace upon signs of wear: clearly reduced autonomy, premature low-battery warnings or slow lifting indicate that the battery has reached the end of its service life (typically 2-3 years depending on intensity of use).
  • Storage: if the lift is to remain unused for long periods, carry out a periodic recharge (every 2-3 months) and avoid deep discharges. At the end of its service life, take the battery to a WEEE collection point; never dispose of it as municipal waste.
  • Variants in our catalogue: if your installed base includes other equipment from the Arjo family, you have available the compatible battery of this same reference (Ref. 88881140, 24 V / 4 Ah AGM), the Arjo Maxilift KKA1100 battery (Ref. 88888029, 24 V / 4 Ah), the Arjo Parker battery (Ref. 88888028, 24 V / 2.5 Ah) and the Arjo Minstrel TGT223 battery (Ref. 88888784, 24 V / 5.5 Ah). Do not interchange these references between models without technical validation.
  • Institutional orders: for purchasing consortia, tenders or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility with your batch of lifts and obtain a formal quotation with special volume-based conditions.

Additional information

Application

Arjo Marisa patient lifting system (original reference NDA0100)

Manufacturer reference

Arjo NDA0100

Technology

Ni-MH (nickel-metal hydride), rechargeable

Nominal voltage

24 V

Capacity

4 Ah (4000 mAh)

Energy

96 Wh (24 V × 4 Ah)

Weight

Approximately 1.2 kg

Dimensions

150 × 80 × 70 mm

Rechargeable

Yes; recharges with the hoist's own charger

Installation

Direct replacement in the lift compartment, without tools

Recycling

Manage in accordance with WEEE regulations

Compatibility

Arjo Marisa hoist; not interchangeable with other models in the Arjo family (Maxi Twin, Tempo, Sarita, Minstrel) without technical validation

Distribution sub-references

NDA0100-03, NDA0100-20, NDA0100-XX, HMX991

Approximate weight

1.2 kg

Market version chemistry

SLA/VRLA AGM 24 V / 4 Ah (≈3.99 kg, 551 × 92 × 56 mm) according to biomedical spare parts manufacturers; verify label and charger

Device manufacturer

Arjo

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Original Arjo Marisa Battery NDA0100 24V 4Ah (96Wh) Ni-MH for Patient Lift | Original Brand Replacement | Ref. 88888718”