Description
1. Reliable power for your Arjo Maxi Twin patient lift
Keep your Arjo Maxi Twin patient lifting system operational with this compatible battery that replaces the original reference NEA0100. With a nominal voltage of 12 V and a capacity of 2.7 Ah (32.4 Wh), this rechargeable battery restores the equipment’s operating time needed for lifting, transferring and moving patients in hospitals, care homes and social health centres, without relying on the mains power supply.
It is the practical solution for maintenance services, biomedical engineering and purchasing departments that need traceable, proven-quality spare parts to keep their fleet of Arjo equipment operational, at a significantly lower cost than the original replacement and with immediate delivery.
2. Technical explanation: how this battery works
The Arjo Maxi Twin patient hoist powers its lifting motor via an internal rechargeable battery when the equipment is not connected to the mains. When the operating time is noticeably reduced, the equipment gives premature low battery warnings or the lifting becomes slow, it is time to replace the battery with this 12 V / 2.7 Ah reference.
The Ni-MH (nickel-metal hydride) chemistry offers a very low memory effect, contains no cadmium and supports repeated charge and discharge cycles with the hoist’s own charger. As a direct replacement compatible spare, it installs in the battery compartment respecting the orientation and connector of the equipment, without the need for tools or adaptations. The robust housing and protection against short circuits and overheating guarantee safe operation in healthcare environments.
3. Technical Specifications
| Characteristic | Specification |
| Application | Arjo Maxi Twin patient lift system (replaces original reference NEA0100) |
| Reference Cahnos (SKU) | 88881142 |
| Compatible reference | NEA0100 |
| Technology | Ni-MH (nickel-metal hydride), rechargeable |
| Nominal voltage | 12 V |
| Capacity | 2.7 Ah (2700 mAh) |
| Energy | 32.4 Wh (12 V x 2.7 Ah) |
| Weight | Approximately 0.75 kg |
| Dimensions | 115 x 75 x 55 mm |
| Device manufacturer | Arjo |
| Rechargeable | Yes; recharge with the lift charger |
| Installation | Direct replacement in the lift compartment, without tools |
| Presentation | 1 unit |
| Recycling | Manage in accordance with WEEE regulations |
Technical note: the commercial data sheet describes this compatible battery as Ni-MH 12 V / 2.7 Ah with an approximate weight of 0.75 kg; however, the technical documentation from biomedical spare parts manufacturers and specialised distributors identifies the original pack that replaces reference NEA0100 mostly as Ni-MH 24 V / 2.5 Ah (or 3.0 Ah), with larger dimensions and weight. Before replacing, check the label on the installed battery and the chemistry for which your equipment’s charger is set.
4. Equivalences and Cross-References
Reference NEA0100 (Arjo Maxi Twin lifting system) has been cross-checked against biomedical battery manufacturers and specialised distribution catalogues. Arjo does not publish an official equivalence table authorising third-party batteries; the following references share the application (hoists / hygiene chairs from the Arjo Maxi Twin, Carendo, Carino and Carevo family) and are classified as comparable by category, not 1:1 interchangeable, and must be validated field by field — voltage, chemistry, dimensions and connector — against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| MSP Medical | Battery Pack 24V/DC 2.5Ah NiMH for Arjo lifts (Carendo, Carevo, Carino, Maxi Twin, Maxi Twin Compact) | MSP-A-AH-00300 (EAN 8719925310041) | Comparable by category (not interchangeable 1:1) | NiMH 24 V / 2.5 Ah; replaces NEA0100 / NEA0100-031; MDR compliant and compatible with the Arjo NEA8000 charger. Voltage and capacity different from the pack in this data sheet (12 V / 2.7 Ah); check charger, connector and dimensions. Confirmed in the spare part manufacturer’s data sheet. |
| Axcom Power Solutions | NiMH battery for Arjo Maxi Twin, Maxi Twin Compact, Carino, Carendo and Carevo | MB083 (EAN 4260201689503) | Comparable by category (not interchangeable 1:1) | NiMH 24 V / 2.5 Ah, with a 24-month warranty and internal quality control; matching equipment family (Maxi Twin). Voltage different from the data sheet (12 V); check connector and battery compartment. Confirmed in the spare part manufacturer’s data sheet. |
| OSI Batteries | Biomedical battery for Arjo Maxi Twin Patient Lift / Carendo Shower Chair | PLB00300 | Comparable by category (not interchangeable 1:1) | NiMH 24 V / 3.0 Ah; replaces NEA0100-083; same application (hoist / hygiene chair). Voltage and capacity different from the data sheet (12 V / 2.7 Ah); check charger, connector and dimensions. Confirmed in the spare part manufacturer’s data sheet. |
| BBM Battery | Biomedical pack no. 6293 for Arjo Maxi Twin Hygiene Chair / Lift | 6293 | Comparable by category (not interchangeable 1:1) | NiMH 24 V / 3.0 Ah; replaces NEA0100-083; also valid for Carendo, Carino, Carevo and Sara Combilizer; slide-in connection; certified by Health Canada. Matching chemistry, different voltage and dimensions; check fit and connector. Confirmed in the spare part manufacturer’s data sheet. |
There is no equivalence table validated by the manufacturer Arjo for this reference; the cross-references indicated come from biomedical battery manufacturers and specialised distributors, so it is recommended to consult the technical department before use in tenders.
5. Selection tips and variants of interest
Confirm the reference of the installed battery: this compatible battery replaces Arjo reference NEA0100 for the Maxi Twin system. Check the numbering printed on the original battery label (NEA0100, NEA0100-083, NEA0100-031) before ordering.
Verify the chemistry and voltage of the battery pack: if your unit has a 24 V pack, the charger is specific to that voltage; do not install a battery of a different voltage or chemistry even if the connector might appear compatible. Given the discrepancy between the commercial data sheet (12 V / 2.7 Ah) and the technical spare parts documentation (24 V / 2.5-3.0 Ah), consult our technical department with the information from your battery label.
Replace upon signs of wear: clearly reduced operating time, premature low battery warnings or slow lifting indicate that the battery has reached the end of its service life (typically 2-3 years depending on intensity of use).
Storage: if the hoist is to remain unused for long periods, carry out a periodic recharge (every 2-3 months) and avoid deep discharges. At the end of its service life, dispose of the battery at a WEEE collection point; never discard it as municipal waste.
Variants in our catalogue: we offer the original version of this same reference (Ref. 88888563), the compatible Arjo Tempo KPA0100 battery (Ref. 88881141, 12 V / 2.7 Ah), the Arjo Sarita KTA0102 battery (Ref. 88881143, 24 V / 2.3 Ah), the Arjo Marisa NDA0100 battery (Ref. 88881140, 24 V / 4 Ah) and the Arjo Minstrel TGT223 battery (Ref. 88889873, 24 V / 5.5 Ah). Do not interchange these references between models without technical validation.
Institutional orders: for consortia, tenders or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility with your fleet of hoists and obtain a formalised quotation with special volume conditions.





Reviews
There are no reviews yet.