We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Battery 12V 1.2Ah for Mortara ELI 50 Electrocardiograph | VRLA Sealed Lead-Acid · Format NP1.2-12 · Ref. 88889503

16,00 €

12 V and 1.2 Ah battery in standard NP1.2-12 format for the Mortara ELI 50 electrocardiograph. Sealed lead-acid (VRLA/AGM) chemistry, leak-proof, maintenance-free and rechargeable, with Faston F1 terminals and direct installation in the equipment battery compartment. High-reliability spare part ensuring constant autonomy for successive ECG recordings in cardiology clinics, emergency departments and primary care. Ref. Cahnos 88889503.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88889503

Description

1. The reliable power source for your Mortara ELI 50

This 12 V and 1.2 Ah battery is the recommended power replacement for the Mortara ELI 50 electrocardiograph, a resting ECG unit widely used in cardiology clinics, emergency departments and diagnostic centres. Its sealed lead-acid (VRLA/AGM) technology ensures a stable, leak-free power supply with the autonomy needed to complete successive examinations without relying on the mains. It is a maintenance-free, rechargeable and highly reliable replacement that restores the unit to full operation within minutes.

2. Technical explanation: how this battery works

The cell uses valve-regulated lead-acid (VRLA) chemistry with absorbed glass mat (AGM) electrolyte, making it leak-proof, rechargeable and suitable for use in portable medical devices. It delivers a nominal voltage of 12 V with a capacity of 1.2 Ah (20-hour rate), sufficient to power the ECG recorder, display and electronics of the ELI 50 during clinical use. Its sealed construction allows spill-proof installation, and its standard cell format NP1.2-12 (97 × 48 × 55 mm) with Faston F1 terminals fits the equipment battery compartment, reusing the original wiring. Like all VRLA cells, it offers a typical design life of 3 to 5 years under nominal use and charge conditions, with good recovery after deep discharges.

3. Technical Specifications

Characteristic Specification
Battery type Sealed lead-acid (VRLA / AGM), maintenance-free
Nominal voltage 12 V
Capacity 1.2 Ah (20-hour rate)
Chemistry Valve-regulated lead-acid, absorbed electrolyte (AGM)
Terminals Faston F1 (0.187 inches / 4.75 mm)
Dimensions (L × W × H) 97 × 48 × 55 mm (NP1.2-12 cell format)
Approximate weight 0.58 kg
Rechargeable Yes
Compatible equipment Mortara ELI 50 Electrocardiograph
Use Power supply for diagnostic equipment (ECG) in hospitals, clinics and diagnostic centres
Estimated life 3-5 years under nominal conditions (typical VRLA)
Installation Direct in the battery compartment, reusing the unit’s wiring
Presentation Unit

4. Equivalences and Cross-References

The cell that powers the Mortara ELI 50 conforms to the standard sealed lead-acid format 12 V / 1.2 Ah with Faston F1 terminals, equivalent to the generic reference cell Yuasa NP1.2-12. The references from other brands listed below belong to the same product category (12 V and 1.2 Ah VRLA battery with F1 terminal) and have been cross-checked against manufacturer datasheets and specialist distribution cross-reference tables; they are classified as comparable by category, not 1:1 interchangeable, and require verification of terminal, dimensions and polarity against the specific unit before replacement.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
GS Yuasa (Yuasa) NP series (VRLA cell) NP1.2-12 / NP1.2-12FR Comparable by category (not interchangeable 1:1) Sealed lead-acid cell 12 V / 1.2 Ah with Faston F1 terminals, 97 × 48 × 55 mm. Confirmed in official manufacturer datasheet and authorised distribution (FR variant with flame-retardant casing). This is the reference cell format for the ELI 50; check the F1 terminal of the batch.
Power-Sonic PS series (General Purpose SLA) PS-1212 Comparable by category (not interchangeable 1:1) 12 V / 1.2 Ah with F1 terminal and AGM technology, confirmed in official manufacturer datasheet. Same electrical performance; in some commercial references the cell height differs slightly from the NP1.2-12 format, so the compartment must be checked before replacement.
Alpha Source OEM replacement for Mortara AS00315 (also AS00220 / AS00811) Comparable by category (not interchangeable 1:1) Sealed lead-acid battery 12 V / 1.2 Ah documented as a spare part for Mortara ELI 50 and INTERP 1000 in specialist distribution tables and medical spare parts catalogue. Confirm terminal version of the order.
OSI Batteries Mortara biomedical battery B00315 Comparable by category (not interchangeable 1:1) SLA battery 12 V / 1.2 Ah for Mortara Instruments ELI 50, confirmed in manufacturer/distributor datasheet with 0.187-inch Faston terminals. Same cell dimensions as NP1.2-12; check terminal orientation.
Interstate Batteries SLA 12 V range SLA1005 Comparable by category (not interchangeable 1:1) 12 V / 1.2 Ah cross-reference included in the compatibility tables for the Mortara ELI 50 from specialist distribution. Check F1 terminal and dimensions before replacement.

Additionally, in specialist distribution tables, the references MK Battery BMED00918, NCE NP1.2-12 and Anybattery 5345-2 appear as cross-codes for the Mortara ELI 50; their full attributes could not be cross-checked against an official manufacturer datasheet, so they are not included as an equivalence row.

There is no equivalence table validated by the equipment manufacturer authorising third-party batteries; consult the technical department before using in tenders. Before replacement, verify each item: voltage (12 V), capacity (1.2 Ah), chemistry (sealed lead-acid VRLA), terminal type (0.187\” Faston F1) and compartment dimensions (NP1.2-12 format).

5. Selection tips and variants of interest

Identify the exact model of your unit: this 12 V / 1.2 Ah battery is the one specified for the Mortara ELI 50. Do not swap it for cells of a different capacity or voltage without prior technical validation: each model in the family supports a specific voltage and capacity.

Check the terminal: the unit requires Faston F1 terminals (0.187\”). Do not replace with cells with terminals of a different size or with integrated wiring without prior validation.

Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the unit is to remain switched off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈10.5 V). Replace the battery when recording autonomy noticeably decreases or the unit gives a low-battery warning.

Variants of the same Mortara family at Cahnos: in addition to this reference for the ELI 50 (ref. 88889503), we have the same cell in a compatible NP1.2-12 format version (ref. 88888958), 12 V / 2.3 Ah battery for ELI 250 (ref. 88889688), 12 V / 7 Ah battery for ELI 380 (ref. 88889604), 12 V battery for ELI 350 (ref. 88881113) and 6 V / 1 Ah battery for ELI 100 (ref. 88888936). Do not swap these references between models: each unit supports a specific voltage and capacity.

For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, lead times and formalised quotation.

Additional information

Battery type

Sealed lead-acid (VRLA / AGM), maintenance-free

Nominal voltage

12 V

Capacity

1.2 Ah (20-hour rate)

Chemistry

Valve-regulated lead-acid, absorbed electrolyte (AGM)

Terminals

Faston F1 (0.187 inches / 4.75 mm)

Dimensions

97 × 48 × 55 mm (NP1.2-12 cell format)

Approximate weight

0.58 kg

Rechargeable

Yes

Compatibility

Mortara ELI 50 Electrocardiograph

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Battery 12V 1.2Ah for Mortara ELI 50 Electrocardiograph | VRLA Sealed Lead-Acid · Format NP1.2-12 · Ref. 88889503”

Your email address will not be published. Required fields are marked *