We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rechargeable Ni-Cd battery 12V 1.8Ah (Cs format) for Fresenius Optima 2 / Optima 3 infusion pump | Replaces 120088-1, 120022P, BATT/110088 · Ref. 88888174

48,00 €

Rechargeable Ni-Cd battery 12 V and 1.8 Ah (Cs format) for Fresenius Optima 2 and Optima 3 infusion/perfusion pumps (Ref. Cahnos 88888174). High-quality compatible replacement that replaces the original part numbers 120088-1, 120022P, 20022, BATT/110022 and BATT/110088, also documented for Fresenius MCM 404, MCM 504 and Volumed VP2000/VP5000. Ensures continuity of infusion during transfers or power cuts, with automatic recharging when the pump is connected to the mains and a minimum battery life of 4 hours at 125 ml/h according to the equipment manufacturer’s manual. Suitable for ICU, emergency, oncology and hospitalisation.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888174

Description

1. Commercial Introduction

Keeping your Fresenius Optima infusion pump running even when no mains power is available is a daily requirement in hospitals, clinics and patient transport services. With the rechargeable 12 V, 1.8 Ah Ni-Cd battery (Ref. Cahnos 88888174) you will have a high-quality compatible spare, ready to install, which replaces the original equipment part numbers 120088-1, 120022P, 20022, BATT/110022 and BATT/110088.

It is the ideal solution for intensive care, emergency, oncology and hospitalisation departments and medical electronics maintenance contracts that need to guarantee continuous patient infusion during transfers, power supply interruptions or equipment movement.

2. Technical explanation of the equipment and the battery

The Fresenius Optima family (Optima 2 and Optima 3, and associated equipment MCM 404, MCM 504 and Volumed VP2000/VP5000) are volumetric infusion pumps that administer fluids, drugs and solutions at a controlled flow rate by means of a peristaltic mechanism, with safety functions such as occlusion and air detection. The pump has an internal rechargeable battery that acts as a backup power source: while the equipment remains connected to the mains, the battery recharges automatically; when the equipment is disconnected or in the event of a power cut, the battery takes over the power supply and the infusion is not interrupted.

This battery uses nickel-cadmium (Ni-Cd) chemistry in Cs format, with a nominal voltage of 12 V and a capacity of 1.8 Ah, providing a stable current output suitable for the pump’s motorised system. The technical manual for the Optima family states a minimum battery life of 4 hours at a flow rate of 125 ml/h. When battery life is noticeably reduced or the pump gives a low-battery warning prematurely, it is time to replace the accumulator with this reference.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) 88888174
Battery type Ni-Cd (nickel-cadmium), rechargeable, maintenance-free
Nominal voltage 12 V
Nominal capacity 1.8 Ah (1800 mAh)
Cell format Cs (sub-C)
Original references covered 120088-1, 120022P, 20022, BATT/110022, BATT/110088
Compatible equipment Fresenius Optima 2, Optima 3; MCM 404, MCM 504; Volumed VP2000, VP5000
Approximate dimensions of the pack 112 x 45 x 46 mm
Approximate weight 0.56 kg
Recharge Automatic with the pump connected to the mains
Battery life Min. 4 h at 125 ml/h (according to the Optima family technical manual)
Intended use Hospital, ICU, emergency, oncology and intra-hospital transport
Presentation 1 unit

Actual battery life depends on the programmed flow rate and the condition of the equipment; consult the pump’s user manual for the battery operating times in each configuration.

4. Equivalences and Cross-References

Ref. Cahnos 88888174 corresponds to the 12 V / 1.8 Ah Ni-Cd battery fitted in the Fresenius Optima pump family (Optima 2 and Optima 3), whose original factory part numbers are 120088-1, 120022P, 20022, BATT/110022 and BATT/110088, consistently verified across multiple technical sources from authorised distribution (including the battery manufacturer’s technical data sheet, which confirms 120088-1 as the manufacturer’s reference, and specialist distribution listings that include the five part numbers for Optima 2/3, MCM 404/504 and Volumed VP2000/VP5000). Fresenius Kabi does not publish an official cross-reference table for this accumulator; the alternatives listed below share voltage, capacity and compatibility and are considered comparable by category, not 1:1 interchangeable, and chemistry, connector and orientation must be verified before installation.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Fresenius Kabi (equipment manufacturer) Original battery Optima 2 / Optima 3 120088-1 Comparable by category (not interchangeable 1:1) Original reference covered by this battery: Ni-Cd 12 V, 1.8 Ah, Cs format, 112 x 45 x 46 mm. Same electrical performance; our spare part is not manufactured by Fresenius Kabi. Confirmed in the battery manufacturer’s technical data sheet and in authorised technical distribution.
Fresenius Kabi (equipment manufacturer) Alternative equipment part numbers 120022P, 20022, BATT/110022, BATT/110088 Comparable by category (not interchangeable 1:1) Alternative part numbers for the same accumulator consistently cited by specialist technical distributors for Optima 2/3, MCM 404/504 and Volumed VP2000/VP5000. Verify the part number printed on the fitted battery.
Cameron Sino CS series for Fresenius Optima / MCM / Volumed CS-FVM404MD Comparable by category (not interchangeable 1:1) Ni-MH 12 V / 1800 mAh (21.6 Wh), 110 x 44.8 x 44.1 mm; replaces 120088-1, 120022P, 20022, BATT/110022 and BATT/110088 and is documented for Optima 2, Optima 3, MCM 404, MCM 504, Volumed VP2000 and VP5000. Ni-MH chemistry as opposed to Ni-Cd; verify compartment and connector. Manufacturer/distributor data sheet consulted.
Axcom MB series for Fresenius MCM 404/504, VP2000/VP5000 MB404 Comparable by category (not interchangeable 1:1) Ni-Cd 12 V, 1.6 Ah (capacity lower than 1.8 Ah), 116 x 49 x 49 mm, 0.54 kg. Different capacity and dimensions; verify space and connector. Battery manufacturer’s technical data sheet and specialist distribution consulted.

There is no equivalence table validated by the manufacturer (Fresenius Kabi) that cross-references this part number with third parties; the alternatives listed are comparable by category and must be checked against the technical data sheet and the equipment manual before use. Consult the technical department before using this reference in tenders.

5. Selection tips and variants of interest

  • Confirm the exact pump model: this battery corresponds to the Optima 2 / Optima 3 family (12 V / 1.8 Ah, Ni-Cd). Do not confuse it with the 6 V / 3 Ah battery for Optima MS (Ref. 88888176) or with the 6 V / 1.8 Ah battery for Injectomat Agilia (Ref. 88888184), even though the connector may look similar.
  • Verify the reference of the fitted battery: check the codes 120088-1, 120022P, 20022, BATT/110022 or BATT/110088 on the accumulator label before replacing. Always respect the voltage (12 V) and the Ni-Cd chemistry; do not use batteries of a different chemistry or voltage without validation from the technical service.
  • Replace when signs of wear appear: clearly reduced battery life or low-battery warnings a few hours after charging indicate that the accumulator has reached the end of its service life.
  • After replacement: leave the pump connected to the mains to complete the charge and verify that the battery indicator reflects the new status before returning the equipment to service.
  • Orders by reference: always quote code 88888174 or that of the original reference (120088-1 / BATT/110088) to avoid confusion with other batteries in the Fresenius family.
  • Other variants of the same family in the catalogue: 88888176 (6 V / 3 Ah for Optima MS), 88888184 (6 V / 1.8 Ah for Injectomat Agilia), 88888173 (6 V / 1.3 Ah for Orchestra MVP-DPS) and 88888186 (6 V / 1.2 Ah for Pilot A-C Prog 1).

If in any doubt, contact our technical department stating the model, serial number and reference of the fitted battery; we will confirm compatibility before finalising the order.

Additional information

Battery type

Ni-Cd (nickel-cadmium), rechargeable, maintenance-free

Nominal voltage

12 V

Capacity

1.8 Ah (1800 mAh)

Cell format

Cs (sub-C)

Compatibility

Fresenius Optima 2, Optima 3; MCM 404, MCM 504; Volumed VP2000, VP5000

Pack dimensions

112 x 45 x 46 mm

Weight

0.56 kg

Recharge

Automatic with the pump connected to the mains

Battery life

Min. 4 h at 125 ml/h (according to the Optima family technical manual)

Maintenance

Maintenance-free; check condition during medical electronics inspections

Intended use

Hospital, ICU, emergency, oncology and intra-hospital transport

Nominal capacity

1.8 Ah (1800 mAh)

Manufacturer reference

120088-1, 120022P, 20022, BATT/110022, BATT/110088

Dimensions

112 x 45 x 46 mm

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable Ni-Cd battery 12V 1.8Ah (Cs format) for Fresenius Optima 2 / Optima 3 infusion pump | Replaces 120088-1, 120022P, BATT/110088 · Ref. 88888174”

Your email address will not be published. Required fields are marked *