Description
1. Product description
At Cahnos we offer you the rechargeable nickel-cadmium battery of 7.2V and 1.8Ah for the syringe pump B. Braun Perfusor FT/P Internal (Ref. Cahnos 88888066), a spare part that replaces the manufacturer’s original reference 34506349 and the alternative part numbers of the same pack 120010 and BRA142. Designed to keep infusion and perfusion running when the equipment is not connected to the mains, this battery provides continuous and stable power during patient transfers, prolonged procedures or power cuts. Available with fast delivery for intensive care, anaesthesia, oncology, emergency, hospitalisation units and medical electronics maintenance contracts.
2. Technical explanation of the equipment and the battery
The B. Braun Perfusor FT/P syringe pump is an electronic infusion device for professional use that administers drugs parenterally continuously or intermittently (anaesthetics, sedatives, analgesics, catecholamines and others) with syringes of different sizes and programmable flow rates. To ensure continuity of therapy also when the patient is mobilised or during transfers without mains power, the device has an internal rechargeable battery that recharges automatically while the pump remains connected to the mains.
This 7.2V and 1.8Ah battery is a nickel-cadmium (Ni-Cd) chemistry pack made up of 1.2V cells in series, which delivers the nominal voltage required by the perfusor and powers the syringe advance motor and the control circuits. It corresponds to the internal triangular format (3-eckige Bauform) of the device, different from the flat external battery of other models in the range (Ref. 34502947). When the battery life is noticeably reduced or the device warns of low battery prematurely, it is time to replace the accumulator with this reference.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888066 |
| Accumulator type | Ni-Cd (nickel-cadmium), rechargeable |
| Nominal voltage | 7.2 V |
| Nominal capacity | 1.8 Ah (1800 mAh) |
| Original equipment reference | 34506349 (B. Braun); alternative part numbers cited: 110010, 120010, BATT/110010, BRA142 |
| Compatibility | Syringe pump B. Braun Perfusor FT/P Internal (triangular internal pack): Perfusor FT, FT91, F, P and secura P; Pousse Seringue FT/P Intérieur |
| Approximate dimensions | 85 x 45 x 40 mm (triangular format, according to distribution technical data sheets; verify with the mounted part) |
| Approximate weight | 0.28 – 0.32 kg |
| Recharge | Automatic, integrated in the pump when connected to the mains |
| Installation | Direct replacement in the equipment compartment, without tools |
| Presentation | 1 unit |
| Intended use | Hospitals, clinics, ICUs, emergency departments, anaesthesia and patient transport |
4. Equivalences and Cross-References
Ref. Cahnos 88888066 replaces the original reference 34506349 of the device manufacturer (B. Braun, triangular internal pack “3-eckige Bauform”), as well as the alternative OEM part numbers 110010, 120010, BATT/110010 and BRA142 consistently cited by the authorised technical distribution for this same pack. The alternatives from other battery manufacturers indicated below have been checked against battery manufacturers’ technical data sheets and authorised distribution catalogues; they are not official B. Braun references and must be validated before replacement (voltage, connector, chemistry and pack dimensions according to batch).
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (device manufacturer) | Original Perfusor FT/P battery (triangular internal pack) | 110010 / 120010 / BATT/110010 / BRA142 | Comparable by category (not interchangeable 1:1) | Alternative OEM part numbers of the same internal pack consistently documented by authorised technical distribution alongside 34506349; verify the part number stamped on the installed battery. |
| Cameron Sino | CS medical series for B. Braun | CS-BRA142MD | Comparable by category (not interchangeable 1:1) | Ni-MH 7.2V / 3000 mAh (21.6 Wh), 86.5 x 53.8 x 38.6 mm, approx. 430-450 g; replaces 34506349, 120010, BATT/110010, BRA142 and 110010; verified in authorised distribution catalogue (CE, RoHS, ISO 9001); much higher capacity and different chemistry (Ni-MH vs Ni-Cd). |
| Axcom Power Solutions | Ni-Cd battery Perfusor FT91 / F / Secura FT | MB1002 | Comparable by category (not interchangeable 1:1) | Ni-Cd 7.2V / 1.2 Ah, 85 x 45 x 40 mm, 0.30 kg, triangular shape, with declaration of conformity; verified in the manufacturer’s data sheet; capacity lower than 1.8 Ah. |
There is no equivalence table validated by the manufacturer (B. Braun) that cross-references this commercial reference with third parties; the references indicated have been verified against battery manufacturers’ data sheets and authorised distribution catalogues, but 1:1 replacement must be validated field by field (chemistry, voltage, capacity, dimensions, connector type and terminal orientation). Consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Confirm the exact pump model: this battery is the one indicated for the B. Braun Perfusor FT/P Internal syringe pump and associated equipment in the range with a triangular internal pack (FT, FT91, F, P, secura P). Do not use it in the external flat battery variant (Ref. 34502947) or in other models of the Perfusor family with a different voltage or connector (e.g., Perfusor Space, FM/D or Compact).
- Respect the voltage: do not use batteries of other voltages (3.6V, 4.8V, 6V) in the Perfusor FT/P even if the connector may look similar; the equipment requires 7.2V nominal.
- Replace when signs of wear appear: clearly reduced battery life or low-battery warnings a few hours after charging indicate that the accumulator has reached the end of its service life.
- Always order by reference: quote code 88888066 or the original equipment reference (34506349) to avoid confusion with other batteries in the B. Braun family.
- For mixed fleets: in our catalogue of batteries for infusion and perfusion pumps we have spare parts for the B. Braun Perfusor Space (88888697), Perfusor FM/D (88888064), Perfusor Compact (88888067) and Infusomat FMS (88888062), as well as for other families on the market.
- Institutional orders: for tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and a formalised quotation.