Battery Cardioline Cardiette AR1200 MFR 120176, power replacement for electrocardiograph from the Cardiette AR1200 series. Nominal voltage of 12 V and capacity of 1.7 Ah (rechargeable Ni-MH technology from the family), original factory reference 120176. Direct replacement component that restores the equipment’s autonomy needed to perform consecutive electrocardiographic recordings without depending on the mains supply, ensuring stable and reliable diagnostics in consultation, emergency and primary care. Cahnos reference (SKU) 88888089; price per unit. Available with delivery in 24-72 h and special conditions for maintenance contracts, hospitals and tenders.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0159041

Description

1. Introduction

Keep your Cardioline Cardiette AR1200 electrocardiograph operational with the original reference replacement battery 120176 (MFR), supplied under reference Cahnos 88888089. This 12 V, 1.7 Ah battery is the power component that ensures the equipment’s clinical continuity during resting examinations, emergencies and primary care, allowing successive electrocardiograms to be completed without mains connection. An essential spare part for cardiology departments, clinics, diagnostic centres and portable equipment fleets, available with immediate delivery.

2. Technical Explanation

The portable electrocardiographs of the Cardiette AR1200 series are powered by an internal rechargeable battery with 12 V nominal voltage and 1.7 Ah capacity (1700 mAh), sufficient to sustain the acquisition of the electrocardiographic recording, processing and thermal printing of the trace during clinical activity. The usual chemistry of this family is Ni-MH (nickel-metal hydride), a rechargeable technology without pronounced memory effect, with good voltage stability during discharge and a typical recovery threshold around 10.5 V for 12 V packs; this information should always be confirmed on the batch label. Replacement is carried out by removing the depleted battery from the equipment compartment and installing the new one respecting the orientation and connector (bayonet mechanism with rotation depending on model), without the need for tools or adaptations. After installation, a full charge and discharge cycle is recommended before clinical use so that the equipment’s battery management system correctly recognises the new pack.

3. Technical Specifications

Field Specification
Application Cardioline Cardiette AR1200 electrocardiograph (Cardiette family)
Original manufacturer reference 120176 (MFR)
Reference Cahnos (SKU) 88888089
Nominal voltage 12 V
Nominal capacity 1.7 Ah (1700 mAh)
Estimated nominal energy* Approx. 20 Wh (12 V × 1.7 Ah)
Type / chemistry Rechargeable Ni-MH battery (nickel-metal hydride); verify batch
Approximate weight* ≈ 0.26 kg (compatible replacements; verify batch)
Approximate dimensions* ≈ 65 × 29 × 50 mm (compatible replacements; verify compartment)
Rechargeable Yes
Installation Direct replacement in the battery compartment

*Data estimated from compatible replacements verified in specialised distribution; must be verified on the batch label and against the equipment compartment before purchase. The main specifications (12 V, 1.7 Ah, reference 120176) come from the official datasheet of the line.

4. Equivalences and Cross-References

The original reference 120176 (Cardioline, Cardiette AR1200 series) has been cross-checked against catalogues of authorised distributors and battery replacement manufacturers. There is no official equivalence table published by the equipment manufacturer that cross-references 120176 with other brands; the following references share the electrical specifications (12 V, 1.7 Ah, Ni-MH chemistry) and have been verified in public datasheets from their respective suppliers, therefore they are classified as comparable by category, not 1:1 interchangeable, and must be validated with the technical department before use in tenders.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
AKKUPOINT (specialised distributor) Medical battery for ECG Recorder Cardiette AR1200 (non-original) 998494 Comparable by category (not interchangeable 1:1) 12 V, 1.7 Ah, Ni-MH; dimensions 65 × 29 × 50 mm and weight 0.26 kg declared in supplier datasheet; declared compatibility with AR1200, AR1200 ADV, AR1200 VIEW and FC1400.
VLAD (authorised distributor, France) 12V 1.7Ah battery for ECG Cardiette AR1200 (120176) 2812017629 Comparable by category (not interchangeable 1:1) Internal distributor code associated with the same reference 120176; same electrical specifications; pending verification of dimensions and connector from the manufacturer’s primary source.
BatteryWeb (replacement, USA) Ni-MH replacement for Cardiette AR1200 / AR1200 ADV / AR1200 VIEW (FC1400) BW-CS-CAR120MD Comparable by category (not interchangeable 1:1) 12 V, 2000 mAh (24 Wh), Ni-MH; claims to replace codes 120176, 110176, 6113, CSA14060 and 88888089; Cardiette bayonet-type connector (45° insertion with clockwise rotation); higher capacity than the original reference (2.0 Ah vs 1.7 Ah).

In specialised distribution, the codes 110176, 6113 and CSA14060 consistently recur as original part numbers associated with the same AR1200 family; each of them could not be cross-checked against the official factory catalogue, so they are considered pending confirmation with the manufacturer before use (not verified in primary source). There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

Identify the exact model of your equipment: the reference 120176 corresponds to the Cardiette AR1200 series; if your unit is an AR1200 ADV or AR1200 VIEW (FC1400) variant, confirm with the technical department the original part number shown on the label of the depleted battery before placing the order.

Check the connector and chemistry: the family uses a twist bayonet connector and 12 V rechargeable packs; do not replace with lead-acid cells or packs with a different connector without prior validation.

First charge cycle: after installing a new Ni-MH battery, perform a full charge and discharge cycle on the bench so that the equipment adjusts its management thresholds and avoids false low-battery warnings during the first clinical use.

Storage: Ni-MH batteries self-discharge at rest; if the equipment remains switched off for long periods, recharge it periodically and avoid the voltage dropping below the recovery threshold (≈ 10.5 V). At the end of its service life, dispose of the battery at a WEEE collection point; never incinerate it.

Variants of the same family at Cahnos: for the Cardiette AR600 we have the MFR BATT/110236 battery at 9.6 V (ref. 88888090); for the Delta 60+ series the MFR 110260 battery at 24 V (ref. 88888778) and for Delta 1+/3 the MFR 1220211-01 (ref. 88888069). Do not interchange these references between models: each unit accepts a specific voltage, capacity and connector. For institutional orders, consortia or maintenance contracts, contact our technical-commercial team at Cahnos to confirm exact compatibility and obtain a formal quotation under B2B volume conditions.

Additional information

Manufacturer reference

120176 (MFR)

Cross references

110176, 6113, CSA14060

Commercial reference

88888089

Nominal voltage

12 V

Capacity

1.7 Ah (1700 mAh)

Chemistry

Rechargeable Ni-MH (AR1200 platform)

Connector type

Cardiette-specific bayonet connector

Application

Electrocardiograph: resting ECG, stress testing and portable recording

Battery type

Rechargeable Ni-MH (nickel-metal hydride); verify batch

Estimated energy

Approx. 20 Wh (12 V × 1.7 Ah)

Compatibility

Cardioline Cardiette AR1200 / AR1200 ADV / AR1200 VIEW (verify model)

Approximate weight

≈ 0.26 kg (compatible replacements; verify batch)

Dimensions

≈ 65 × 29 × 50 mm (verify compartment)

Rechargeable

Yes

Use

Electrocardiograph (ECG): portable power for consultations, emergencies and primary care

Installation

Direct replacement in the battery compartment

Cross-reference codes pending

110176, 6113, CSA14060 (cited in distribution; pending confirmation from manufacturer)