We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Battery for Welch Allyn AED 10 Defibrillator (Ref. 1852 / 00185-2) | Lithium-Manganese Dioxide 12 V Non-Rechargeable – Ref. Cahnos 88888647

32,00 €

Replacement battery for Welch Allyn DSA AED 10 defibrillator (manufacturer ref. 1852 / 00185-2 / 001852-U): primary lithium-manganese dioxide (Li-MnO₂) cell, 12 V and 1.4 Ah, non-rechargeable and maintenance-free. Replicates the original unit supplied as standard with the AED 10 and AED 10 Jump Start, with quick tool-free replacement and a storage life managed by expiry date (FIFO rotation). Immediate availability for emergencies, ambulances, hospitals, companies and public access resuscitation points. Cahnos reference 88888647 (SKU 0159019).

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0159019

Description

1. Introduction

Keep your defibrillator Welch Allyn DSA AED 10 always operational with the replacement battery that matches the unit’s original equipment (MFR 1852). Designed as a non-rechargeable primary lithium cell, this battery eliminates any charging and maintenance routine: the AED 10 remains on standby with full response capability and only requires you to periodically check its status indicator and expiry date. An essential solution for emergency services, ambulances, hospitals, companies and public access spaces that manage defibrillation programmes.

2. Technical explanation of the equipment

The DSA AED 10 is a semi-automatic external defibrillator (AED) from Welch Allyn designed for response to cardiorespiratory arrest. One of its operational keys is precisely its power source: a primary lithium-manganese dioxide (Li-MnO₂) battery of 12 V and 1.4 Ah, single-use and non-rechargeable. As a primary cell, the battery does not experience loss from charge cycles or accelerated self-discharge, allowing the device to remain in standby mode for long periods and deliver an effective immediate shock when needed. The AED 10 performs periodic self-tests that monitor battery status and warn before depletion; replacement is manual, quick and requires no tools. Due to its disposable nature, spare parts management must be done by expiry date (FIFO rotation), ensuring that the installed unit is always within its storage shelf life.

3. Technical Specifications

Parameter Value
Battery type Primary lithium battery, non-rechargeable (single-use)
Chemistry Lithium-manganese dioxide (Li-MnO₂)
Nominal voltage 12 V
Nominal capacity 1.4 Ah (1400 mAh)
Rechargeable No
Maintenance Maintenance-free
Compatibility Defibrillator Welch Allyn DSA AED 10 / AED 10 Jump Start
Manufacturer reference (MFR) 1852 (also coded 001852 / 00185-2)
Reference Cahnos 88888647
Presentation Unit
Use environments Emergency care, hospitals, medical transport, public spaces
Reference data Value
Compatible equipment Welch Allyn DSA AED 10 (semi-automatic external defibrillator, AED)
OEM reference Welch Allyn 001852 / 00185-2
Market-cited codes 001852-U, 640-1112-00 rev (from distributors; verify against the label of the installed battery)
Spare part nature Battery matching the original unit supplied as standard with the AED 10

4. Equivalences and Cross-References

This battery corresponds to the original unit Welch Allyn ref. 001852 / 00185-2 (exact reference equivalence within the same manufacturer: same family, same specifications; identical to the standard battery of the AED 10). However, there is no manufacturer-validated equivalence table that would allow replacing this battery with that of another defibrillator: each manufacturer uses its own chemistry, connector and management electronics. The following references share the type of non-rechargeable primary lithium battery for AEDs and are classified as comparable by category, not interchangeable 1:1.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
ZOLL AED Pro non-rechargeable battery 8000-0860-01 (Cahnos 88888634) Comparable by category (not interchangeable 1:1) Same Li-MnO₂ chemistry and 12 V, but 4.2 Ah capacity and proprietary connector/electronics of the AED Pro.
Defibtech DSA-DEA 5 Years DBP-1400 (Cahnos 88888845) Comparable by category (not interchangeable 1:1) Primary lithium battery for AED of 15 V / 1.4 Ah; voltage and connector different from the AED 10 (12 V).
Defibtech DSA-DEA 7 Years DBP-2800 (Cahnos 88888931) Comparable by category (not interchangeable 1:1) Primary lithium battery of 15 V / 2.8 Ah, up to 300 shocks or 7 years; not interchangeable with the AED 10.
Philips HeartStart FR3 989803150161 (Cahnos 88888783) Comparable by category (not interchangeable 1:1) Lithium 12 V / 4.2 Ah for the FR3 AED; connector and power management exclusive to Philips.

Reference verification note: in the GUDID (FDA) regulatory database, code 001852 appears associated with an AirLife HEPA filter from CareFusion, i.e., a different product; the original AED 10 battery is documented in catalogues and distributors with the codes 001852 / 00185-2 / 001852-U / 640-1112-00. It is recommended to confirm the reference engraved on the installed battery before placing the order. Additional caution: do not confuse it with battery 8000-0807-01, which in our catalogue corresponds to the AED+ from Welch Allyn (3 V lithium, Cahnos 88888976); some distributors cite it as a cross for the AED 10, a fact that could not be verified. There is no manufacturer-validated equivalence table for this battery; consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Identify the device: this battery corresponds to the Welch Allyn DSA AED 10 defibrillator (also AED 10 Jump Start). Confirm the exact model and the reference engraved on the battery to be replaced.
  • Expiry management: as it is a non-rechargeable primary battery, establish FIFO stock rotation and replace the unit before its expiry date even if the device has not recorded any shocks.
  • Check the device indicator: the AED 10 monitors the battery in its self-tests; respond to low battery warnings with a new verified unit.
  • Do not confuse it with other AED batteries: the batteries from ZOLL AED Pro (8000-0860-01), Philips HeartStart or Defibtech DSA-DEA are not interchangeable with the AED 10 due to connector, voltage and management electronics.
  • Accessories: also check the condition and expiry date of the defibrillation electrodes of the AED 10 to keep the unit fully operational.
  • Recommended environments: public access resuscitation points, ambulances, healthcare centres and locations with intermittent use where a rechargeable battery would lose charge through self-discharge.
  • Recycling: dispose of the spent battery at authorised WEEE collection points in accordance with current regulations.
  • For volume orders or tenders, contact the technical department of Cahnos indicating the model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order.

Additional information

Manufacturer reference

1852 / 001852 / 00185-2 (Welch Allyn)

Product type

Primary lithium battery, non-rechargeable (single-use)

Chemistry

Lithium-manganese dioxide (Li-MnO₂)

Nominal voltage

12 V

Capacity

1.4 Ah (1400 mAh)

Rechargeable

No

Maintenance

Maintenance-free

Compatibility

Defibrillator Welch Allyn DSA AED 10 / AED 10 Jump Start

Use

Disposable; replace by expiry date (FIFO rotation)

Scope of use

Emergency care, hospitals, medical transport, public spaces

Mounting

Quick replacement without tools

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Battery for Welch Allyn AED 10 Defibrillator (Ref. 1852 / 00185-2) | Lithium-Manganese Dioxide 12 V Non-Rechargeable – Ref. Cahnos 88888647”