Description
1. Introduction
Keep your defibrillator Welch Allyn DSA AED 10 always operational with the replacement battery that matches the unit’s original equipment (MFR 1852). Designed as a non-rechargeable primary lithium cell, this battery eliminates any charging and maintenance routine: the AED 10 remains on standby with full response capability and only requires you to periodically check its status indicator and expiry date. An essential solution for emergency services, ambulances, hospitals, companies and public access spaces that manage defibrillation programmes.
2. Technical explanation of the equipment
The DSA AED 10 is a semi-automatic external defibrillator (AED) from Welch Allyn designed for response to cardiorespiratory arrest. One of its operational keys is precisely its power source: a primary lithium-manganese dioxide (Li-MnO₂) battery of 12 V and 1.4 Ah, single-use and non-rechargeable. As a primary cell, the battery does not experience loss from charge cycles or accelerated self-discharge, allowing the device to remain in standby mode for long periods and deliver an effective immediate shock when needed. The AED 10 performs periodic self-tests that monitor battery status and warn before depletion; replacement is manual, quick and requires no tools. Due to its disposable nature, spare parts management must be done by expiry date (FIFO rotation), ensuring that the installed unit is always within its storage shelf life.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Battery type | Primary lithium battery, non-rechargeable (single-use) |
| Chemistry | Lithium-manganese dioxide (Li-MnO₂) |
| Nominal voltage | 12 V |
| Nominal capacity | 1.4 Ah (1400 mAh) |
| Rechargeable | No |
| Maintenance | Maintenance-free |
| Compatibility | Defibrillator Welch Allyn DSA AED 10 / AED 10 Jump Start |
| Manufacturer reference (MFR) | 1852 (also coded 001852 / 00185-2) |
| Reference Cahnos | 88888647 |
| Presentation | Unit |
| Use environments | Emergency care, hospitals, medical transport, public spaces |
| Reference data | Value |
|---|---|
| Compatible equipment | Welch Allyn DSA AED 10 (semi-automatic external defibrillator, AED) |
| OEM reference Welch Allyn | 001852 / 00185-2 |
| Market-cited codes | 001852-U, 640-1112-00 rev (from distributors; verify against the label of the installed battery) |
| Spare part nature | Battery matching the original unit supplied as standard with the AED 10 |
4. Equivalences and Cross-References
This battery corresponds to the original unit Welch Allyn ref. 001852 / 00185-2 (exact reference equivalence within the same manufacturer: same family, same specifications; identical to the standard battery of the AED 10). However, there is no manufacturer-validated equivalence table that would allow replacing this battery with that of another defibrillator: each manufacturer uses its own chemistry, connector and management electronics. The following references share the type of non-rechargeable primary lithium battery for AEDs and are classified as comparable by category, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| ZOLL | AED Pro non-rechargeable battery | 8000-0860-01 (Cahnos 88888634) | Comparable by category (not interchangeable 1:1) | Same Li-MnO₂ chemistry and 12 V, but 4.2 Ah capacity and proprietary connector/electronics of the AED Pro. |
| Defibtech | DSA-DEA 5 Years | DBP-1400 (Cahnos 88888845) | Comparable by category (not interchangeable 1:1) | Primary lithium battery for AED of 15 V / 1.4 Ah; voltage and connector different from the AED 10 (12 V). |
| Defibtech | DSA-DEA 7 Years | DBP-2800 (Cahnos 88888931) | Comparable by category (not interchangeable 1:1) | Primary lithium battery of 15 V / 2.8 Ah, up to 300 shocks or 7 years; not interchangeable with the AED 10. |
| Philips | HeartStart FR3 | 989803150161 (Cahnos 88888783) | Comparable by category (not interchangeable 1:1) | Lithium 12 V / 4.2 Ah for the FR3 AED; connector and power management exclusive to Philips. |
Reference verification note: in the GUDID (FDA) regulatory database, code 001852 appears associated with an AirLife HEPA filter from CareFusion, i.e., a different product; the original AED 10 battery is documented in catalogues and distributors with the codes 001852 / 00185-2 / 001852-U / 640-1112-00. It is recommended to confirm the reference engraved on the installed battery before placing the order. Additional caution: do not confuse it with battery 8000-0807-01, which in our catalogue corresponds to the AED+ from Welch Allyn (3 V lithium, Cahnos 88888976); some distributors cite it as a cross for the AED 10, a fact that could not be verified. There is no manufacturer-validated equivalence table for this battery; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Identify the device: this battery corresponds to the Welch Allyn DSA AED 10 defibrillator (also AED 10 Jump Start). Confirm the exact model and the reference engraved on the battery to be replaced.
- Expiry management: as it is a non-rechargeable primary battery, establish FIFO stock rotation and replace the unit before its expiry date even if the device has not recorded any shocks.
- Check the device indicator: the AED 10 monitors the battery in its self-tests; respond to low battery warnings with a new verified unit.
- Do not confuse it with other AED batteries: the batteries from ZOLL AED Pro (8000-0860-01), Philips HeartStart or Defibtech DSA-DEA are not interchangeable with the AED 10 due to connector, voltage and management electronics.
- Accessories: also check the condition and expiry date of the defibrillation electrodes of the AED 10 to keep the unit fully operational.
- Recommended environments: public access resuscitation points, ambulances, healthcare centres and locations with intermittent use where a rechargeable battery would lose charge through self-discharge.
- Recycling: dispose of the spent battery at authorised WEEE collection points in accordance with current regulations.
- For volume orders or tenders, contact the technical department of Cahnos indicating the model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order.