Description
1. Factory power for your Primedic M290 defibrillator
At Cahnos we provide the original Primedic AkuPak LITE battery for the M290 monitor defibrillator from the Metrax group, corresponding to factory reference MFR 97196 (Ref. Cahnos 88881073). It is the rechargeable lithium iron phosphate (LiFePO₄) battery fitted as standard on the device: 13.2 V, 2.5 Ah and 33 Wh of energy, with a charge level indicator and external charging contacts.
It is the ideal solution for medical electronics services, biomedical engineering, ambulances, hospitals and maintenance contracts that need a traceable, direct-fit spare part with the reliability required of a professional-use defibrillator.
2. Technical explanation: how this battery works in the M290
The Primedic M290 monitor defibrillator (DefiMonitor XD series) can be powered from the mains or from its internal battery. When the device is operating without mains power, the AkuPak LITE supplies energy to the analysis electronics, the screen, monitoring and capacitor charging for the biphasic discharge. This battery uses LiFePO₄ (lithium iron phosphate) chemistry, a rechargeable technology with high energy density, no memory effect and a service life of up to 4 years from the date of manufacture or approximately 1,000 charge cycles.
According to the manufacturer’s technical documentation for this reference, the AkuPak LITE provides approximately 150 discharges at 200 J or about 95 discharges at 360 J per full cycle. It is supplied in transport or “sleep” mode to guarantee at least 12 months of storage without recharging, and can be recharged in the defibrillator itself, in the Base Charger (96344) or with the ClipCharger (097004). A fully discharged battery takes approximately 2 hours to charge.
Signs of depletion: reduced autonomy, a number of discharges per cycle clearly below the nominal value, or premature low-battery warnings indicate that it is time to replace the battery.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference Cahnos (SKU) | 88881073 |
| Manufacturer reference (MFR) | 97196 (previous/equivalent MFR 97195) |
| Commercial model | Primedic AkuPak LITE |
| Compatible equipment | Monitor defibrillator Primedic M290; HeartSave 6 / 6S / AED-M / DefiMonitor XD platform (XD1, XD3, XD10, XD30, XD100, XD110, XD300, XD330) compatible according to manufacturer |
| Battery type | Rechargeable LiFePO₄ (lithium iron phosphate) |
| Nominal voltage | 13.2 V DC |
| Nominal capacity | 2.5 Ah (2,500 mAh) |
| Energy | 33 Wh |
| Performance per cycle | ≈ 150 discharges at 200 J; ≈ 95 discharges at 360 J (manufacturer) |
| Weight-bearing time | ≈ 2 hours (fully discharged) |
| Shelf life | Up to 4 years from the date of manufacture; ≈ 1,000 charge cycles |
| Transport mode | Factory “sleep” mode: ≥ 12 months of storage without recharging |
| Memory effect | No |
| Approximate dimensions | 240 × 65 × 40 mm (according to authorised distribution technical data sheet; may vary slightly by batch) |
| Approximate weight | 0.56 kg |
| Charge indicator | Yes, charge level display on the battery itself |
| External charging contacts | Yes, for Base Charger and ClipCharger |
| Installation | Direct replacement in the equipment compartment, without tools |
| Presentation | 1 unit |
| Recycling | RAEE/WEEE management; do not dispose of as municipal waste |
4. Equivalences and Cross-References
The MFR 97196 reference is confirmed in catalogues and technical data sheets from authorised European distribution (VLAD, Akkuplanet, Akkumed, Euro Energy, Hestomed) and in the official documentation of the Metrax/Primedic group, which consistently describe it as the rechargeable AkuPak LITE battery of 13.2 V and 2.5 Ah (33 Wh) for the M290 / HeartSave 6 / DefiMonitor XD platform. The previous reference, MFR 97195, corresponds to the same physical platform, which is why most replacement manufacturers treat them as equivalent for mechanical and electrical purposes. No record of this reference has been located in the GUDID/FDA database with this description.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Cameron Sino | Medical series compatible with Primedic AED-M / Defimon XD3 / HeartSave 6 / M250 / M290 | CS-PRH600MD | Comparable by category (not interchangeable 1:1) | Third-party replacement with Li-MnO₂ chemistry of 15.5 V / 7,200 mAh and dimensions 242 × 64.2 × 41.5 mm; it matches the mechanical compatibility of the 97195/97196 platform, but differs in voltage (15.5 V vs 13.2 V), chemistry (primary Li-MnO₂ vs rechargeable LiFePO₄) and capacity. It is not 1:1 interchangeable: the M290 charger cannot recharge a primary cell. Confirmed in replacement manufacturer data sheets and specialised distribution. |
| KingSener / BatteryMall | Replacement for Metrax Primedic Akupak DefiMonitor XD / M290 | 73910112686 | Comparable by category (not interchangeable 1:1) | Third-party spare part with the same electrical specification (LiFePO₄, 13.2 V / 2.5 Ah / 33 Wh) and declared compatibility with the serial numbers of the M290 platform; without the equipment manufacturer’s own CE declaration. Verify connector, dimensions and batch. Confirmed in the spare part manufacturer’s datasheet. |
There is no equivalence table validated by the manufacturer (Primedic / Metrax) that cross-references reference 97196 with batteries from other defibrillator manufacturers: defibrillation platforms are proprietary and differ in connector, voltage, chemistry and charging protocol. Replacement with third-party spare parts requires field-by-field validation (rechargeable LiFePO₄ chemistry, 13.2 V, charging connector, dimensions and the device’s battery management system) by the technical department before use in tendering.
5. Selection tips and variants of interest
Identify the reference of the installed battery: check on the battery label the MFR 97196 code (or the previous variant 97195) and the device model before placing the order. This reference covers the Primedic M290 monitor defibrillator, as well as the AEDs of the HeartSave 6 / 6S / AED-M family and the DefiMonitor XD units compatible according to the manufacturer.
Respect the chemistry and voltage: the M290 is configured for the 13.2 V rechargeable LiFePO₄ battery. Do not install 15 V primary lithium batteries (type 97640/97641) or spare parts of another chemistry: the device charger can only recharge rechargeable batteries from this platform.
Preventive replacement: replace the battery when it approaches the end of its service life (4 years from manufacture) or when the number of discharges per cycle is clearly lower than specified. Perform a periodic recharge every 2-3 months if the device remains in prolonged stand-by to avoid deep discharges.
Compatible chargers: use the Charger base (ref. 96344) or the ClipCharger (ref. 097004) for external recharging; a non-compatible charger can damage the battery and the device.
Primedic family variants at Cahnos: batteries are available for other models of the same family, such as M240 (Ref. 88881154), HeartSave M250 (Ref. 88888943, non-rechargeable lithium battery) and the SaverOne series. Do not interchange these references between models without technical validation.
Institutional orders: for consortia, tenders or fleet maintenance contracts, contact our technical-commercial department stating the model and reference of the installed battery; we will confirm compatibility before finalising the order.





Reviews