Description
Maximum reliability for your Philips defibrillator-monitor
The Philips Efficia DFM100 989803190371 battery is the lithium-ion accumulator designed by Philips to power the Efficia DFM100 defibrillator-monitor (DFM-100). It is a high-capacity, long-lasting original replacement that ensures the equipment is always operational and ready to act in critical situations of resuscitation, monitoring and medical transport.
With the Cahnos reference 88889059, this battery guarantees maximum compatibility and electrical safety, complying with what is specified in the manufacturer’s own official instruction manual.
Technical explanation: why this battery is key
The Efficia DFM100 from Philips is a portable defibrillator-monitor with four clinical modes: monitoring (ECG, SpO2, EtCO2 and NBP), manual defibrillation and synchronised cardioversion, semi-automatic defibrillation (AED) and external transcutaneous pacing. It operates on mains power or internal battery when moving the patient, in ambulances or in procedures without a nearby power outlet.
The 14.8 V lithium-ion battery supplies the energy needed for discharges with the SMART Biphasic waveform, continuous monitoring and event recording. A new, fully charged battery provides, at 20 °C, up to 100 complete charge/discharge cycles, or more than 2.5 hours of monitoring plus 20 full-energy discharges, or 2 hours of pacing (180 ppm, 140 mA, 40 ms). The integrated capacity indicator (gauge) allows checking the charge level without inserting the battery into the equipment.
Philips recommends keeping the battery always charged and having a spare one available, since the equipment’s Ready For Use (RFU) indicator directly depends on the state of the accumulator.
Technical specifications
| Characteristic | Value |
|---|---|
| Battery type | Rechargeable lithium-ion (Li-ion) |
| Nominal voltage | 14.8 V (minimum 14.4 V) |
| Nominal capacity | 5.0 Ah (5000 mAh) |
| Nominal energy | 74 Wh |
| Original manufacturer reference | 989803190371 (also referred to as M6482) |
| Reference Cahnos | 88889059 |
| Compatible equipment | Defibrillator-monitor Philips Efficia DFM100 / DFM-100 |
| Approximate dimensions | 145.7 x 80 x 28.5 mm |
| Approximate weight | 0.44 kg |
| Charge indicator | Yes (capacity gauge on the battery itself) |
| Charging time (equipment off and on mains) | Less than 2 h at 80%; less than 3 h at 100% |
| Battery life (new battery at 20 °C) | 100 complete charge/discharge cycles, or 2.5 h of monitoring + 20 discharges, or 2 h of pacing |
| Estimated service life | Approx. 3 years in moderate use; approx. 1.5 years in intensive use |
| Presentation | Unit |
| Recycling | Management in accordance with WEEE regulations |
Data verified against the official Philips instruction manual (IFU 453564403811) and authorised biomedical distribution datasheets.
Equivalences and cross-references
Note on nomenclature: the manufacturer’s official reference is 989803190371 (identified on the Philips product website as Efficia DFM100 Battery). In the replacement market, the service part M6482 is consistently cited for this same battery, as well as the variants 989503190371 and 9898031903 in compatibility tables from specialised distributors. The third-party cross-references indicated below belong to the same product category (Li-ion biomedical battery 14.8 V for Efficia DFM100) and have been verified in catalogues of replacement battery manufacturers; they are classified as comparable by category, not 1:1 interchangeable, and require verification of the battery management protocol (BMS) before replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Philips (original manufacturer) | OEM battery for Efficia DFM100 | 989803190371 | Exact reference equivalence (same manufacturer) | Standard battery for the Efficia DFM100 defibrillator-monitor; Li-ion, 14.8 V, 5.0 Ah (74 Wh), with capacity indicator. |
| Philips (original manufacturer) | Service part for DFM100 battery | M6482 | Exact reference equivalence (same manufacturer) | OEM reference consistently cited in authorised distribution and spare parts catalogues for the Efficia DFM100 battery; same Li-ion chemistry and voltage of 14.8 V. |
| Philips (original manufacturer) | Previous revision of the battery | 989503190371 / 9898031903 | Not verified | Variants cited in third-party compatibility tables as substitutes for the 989803190371; confirm with the manufacturer before use. |
| Cameroon Batteries (replacement) | Replacement battery for DFM100 | CS-PHM100MD | Comparable by category (not interchangeable 1:1) | 14.8 V, 5200 mAh, Li-ion; replaces M6482 / 989803190371 according to replacement manufacturer datasheet. Verify BMS handshake, connector and seating in the compartment. |
| Kingsener (replacement) | Replacement battery for DFM100 | PHM100MD | Comparable by category (not interchangeable 1:1) | 14.8 V, 5200 mAh, Li-ion (cells 4ICR19/66-2); confirm declared capacity and equipment self-test before replacement. |
There is no official equivalence table validated by the manufacturer that cross-references this reference with third-party batteries; the codes CS-PHM100MD and PHM100MD come from replacement battery manufacturers and must be checked with the technical department before use in tenders or replacement of an in-service unit.
Selection tips and variants of interest
- Confirm the model printed on your equipment’s label: it must be Philips Efficia DFM100 / DFM-100.
- Replace the battery when the equipment shows the low battery warning (Low Battery) or when the gauge indicates less than 40% charge.
- Charge the battery with the equipment switched off and connected to the mains: it reaches 80% in less than 2 hours and 100% in less than 3 hours.
- If the equipment is to remain unused for a long time, remove the battery and store it between 15 and 35 °C with a charge of 20 to 40%, checking its level every two months.
- Renew the accumulator when the equipment indicates Replace Battery or when it detects a failed communication with the battery.
- Variants of interest for other Philips/Laerdal defibrillators available at Cahnos: 88888783 (HeartStart FR3, 989803150161), 88888342 (HeartStart HS1, M5070A), 88888363 (HeartStart MRx, M3538A), 88881012 (HeartStart XL, 989803167281) and 88889102 (HeartStart FR1).