Description
1. Original standby power for your Nihon Kohden defibrillator
Keep your Nihon Kohden Cardiolife AED-2100 automated external defibrillator always operational with this genuine brand battery, factory reference X217A (OEM pack codes: SB-214VK / NKPB-28271K, Ref. Cahnos 88889156). It is the spare part that ensures the equipment is immediately available in emergencies, medical transport, health centres and public spaces with an AED: rhythm analysis, CPR instructions and biphasic shock without depending on the mains supply.
As an original replacement from Nihon Kohden, it guarantees full compatibility with the equipment, factory performance and the replacement schedule specified by the manufacturer, with the technical and commercial support of Cahnos for institutional purchases, defibrillator fleets and public tenders.
2. How this battery works: technical explanation
The X217A reference is the disposable primary lithium-manganese dioxide (Li-MnO2) battery that Nihon Kohden installs in the defibrillators of the Cardiolife AED-2100 series: units AED-2100, AED-2100K, AED-2150, AED-2150K, AED-2150P, AED-2151 and AED-2152 (always verify the unit’s serial number).
Unlike the rechargeable batteries of other equipment, this cell is not rechargeable: it delivers a stable voltage of 27 V with a capacity of 2.8 Ah (approx. 72.9–75.6 Wh) and remains on standby powering the self-diagnostic electronics for approximately 2 years (some channel variants declare up to 4 years of service life and factory expiry). When the equipment detects depletion, it indicates this via the self-test and the status signals on the panel; replacing it with this reference restores the AED to full operational status in minutes, preventing a critical resuscitation unit from being out of service. In the manufacturer’s specialised distribution channel, the X217A reference consistently appears associated with the OEM codes SB-214VK and NKPB-28271K, which designate the same cell.
3. Technical Specifications
Data cross-checked against the technical information from the manufacturer’s specialised distribution channel (medical battery datasheets for the Cardiolife AED-2100 series) and against Cahnos’s internal reference register. The X217A reference has not been found in public regulatory databases GUDID/FDA or EUDAMED as of the date this datasheet was prepared; the voltage, capacity and chemistry data are, however, consistently confirmed in multiple technical datasheets from the manufacturer’s channel.
| Parameter | Detail |
|---|---|
| Reference Cahnos (SKU) | 88889156 |
| Nihon Kohden factory reference | X217A (pack OEM codes: SB-214VK / NKPB-28271K) |
| Application / compatibility | Defibrillator Cardiolife AED-2100, AED-2100K, AED-2150, AED-2150K, AED-2150P, AED-2151 and AED-2152 (Cardiolife AED-2100 series; verify serial number) |
| Type / technology | Disposable primary lithium-manganese dioxide (Li-MnO2) battery, non-rechargeable |
| Nominal voltage | 27 V |
| Capacity | 2.8 Ah (2700–2800 mAh depending on source) |
| Useful energy | Approx. 72.9 – 75.6 Wh |
| Standby duration | Approx. 2 years in standby mode (up to 4 years of advertised service life in some variants) |
| Approximate dimensions | 170 – 180 × 57 – 59 × 45 – 46.8 mm (depending on source and batch) |
| Approximate weight | Approx. 0.48 kg |
| Rechargeable | No (scheduled replacement based on device alert) |
| Mounting type | Direct replacement in the AED battery compartment, no tools required |
| Presentation | 1 unit |
| Recycling | Do not dispose of as household waste; recycle in accordance with WEEE regulations |
4. Equivalences and Cross-References
The factory reference X217A corresponds to the primary Li-MnO2 cell of 27 V / 2.8 Ah that Nihon Kohden installs in the Cardiolife AED-2100 platform; in the specialised distribution channel it is consistently cited in association with the OEM codes SB-214VK and NKPB-28271K, which designate the same battery. Nihon Kohden does not publish an official equivalence table authorising third-party batteries; the indicated alternatives share chemistry (Li-MnO2), voltage (27 V) and capacity window (2.7–2.8 Ah), and have been cross-checked in their own manufacturer’s datasheet, but they are classified as comparable by category, not 1:1 interchangeable, and require verification of connector, dimensions and batch against the specific equipment before replacement.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Nihon Kohden (factory designations) | Cardiolife AED-2100 / AED-2100K / AED-2150 / AED-2150K / AED-2150P / AED-2151 / AED-2152 | X217A = SB-214VK = NKPB-28271K | Exact reference equivalence (same manufacturer) | OEM designations of the same primary Li-MnO2 cell of 27 V / 2.8 Ah, consistently confirmed in the manufacturer’s specialised distribution channel (e.g. datasheets from VLAD, Axel and medical distribution); always verify the equipment’s serial number. |
| Cameron Sino Technology (Medical) | Medical battery for Nihon Kohden Cardiolife AED-2100 range (AED-2100, AED-2150, AED-2150K, AED-2150P, AED-2151, AED-2152) | CS-NKC210MD | Comparable by category (not interchangeable 1:1) | Li-MnO2 of 27 V / 2700 mAh (72.9 Wh), non-rechargeable primary cell, 176 × 59 × 46.2 mm, 427 g, orange, EAN 4894128203551; replaces X217A / SB-214VK / NKPB-28271K. Different pack manufacturer (not original Nihon Kohden); confirmed in manufacturer and specialised distribution datasheets; verify connector, dimensions and batch before replacement. |
| Rhino Power Limited (Battery-Market / RHINO POWER) | High-capacity battery for Nihon Kohden AED-2100 / AED-2100K / AED-2150 / AED-2150P / AED-2150K / AED-2151 / AED-2152 | NKPB-28271K (RHINO POWER series) | Comparable by category (not interchangeable 1:1) | Li-MnO2 of 27 V / 2800 mAh, non-rechargeable primary cell, high-capacity orange pack; replaces X217A / SB-214VK / NKPB-28271K. Different pack manufacturer (not original Nihon Kohden); confirmed in the manufacturer’s official datasheet; verify connector, dimensions and batch before replacement. |
There is no equivalence table validated by the manufacturer (Nihon Kohden) authorising third-party batteries for the X217A reference; consult the technical department before use in tenders. Caution: some marketplaces list «SB-214VK / NKPB-28271K» with divergent specifications (e.g. 12 V and 4200 mAh lithium-ion); these have not been considered equivalent as they do not match the OEM datasheet (27 V / 2.8 Ah Li-MnO2). Nor should this reference be confused with the SB-212VK / NKPB-14301K (30 V / 1.4 Ah, Ref. Cahnos 88888974), which corresponds to another cell of the same AED-2100 platform; always verify the voltage and reference printed on the removed battery.
5. Selection tips and variants of interest
Before replacing the battery, verify three parameters on the label of the removed cell: technology (Li-MnO2, non-rechargeable), voltage (27 V) and factory reference (X217A, SB-214VK or NKPB-28271K), and confirm the defibrillator’s serial number to ensure it corresponds to the AED-2100/2150 platform.
Do not confuse it with other batteries in the Nihon Kohden family: the SB-212VK / NKPB-14301K is a 30 V / 1.4 Ah cell also cited for the AED-2100 (Ref. Cahnos 88888974), and the Cardiolife TEC-5500/5600/7600/7700 defibrillator-monitors use the X065 (Ni-MH 12 V, Ref. Cahnos 88888424). Each device has its specific cell: always check the installed battery before purchasing.
Preventive maintenance: primary Li-MnO2 batteries are not rechargeable; replace the cell on a scheduled basis after approximately 2 years of service or upon the battery warning from the self-test, and rotate the backup units to avoid leaving the AED out of service. For defibrillator fleets and tenders, contact our technical department stating the model and serial number of the device; we will confirm compatibility before finalising the order and will offer you special terms for volume orders.





Reviews