Description
1. Product Presentation
The ECG thermal paper pack (ref. 33026, SKU GM33026) is the recording consumable that keeps your Nihon Kohden electrocardiograph operational with maximum trace quality. Each pack contains 215 heat-sensitive sheets of 210 x 140 mm with a pre-printed white grid and marker, ensuring clear, stable and easily archivable electrocardiograms in every examination. Its presentation in a box of 10 units is designed to ensure continuous replenishment for the care service in cardiology, emergency, primary care and functional testing units.
2. Technical Explanation
This consumable uses direct thermal printing technology: the electrocardiograph’s thermal head transfers heat to the paper’s heat-sensitive layer and generates the trace instantly, without the need for ink, toner or ribbon, which reduces equipment maintenance and maintains consistent print quality throughout the entire pack. The pre-printed grid acts as a measurement reference on the paper itself: it allows assessment of wave amplitude (mV), interval duration (PR, QT, RR) and recording speeds (mm/s), facilitating clinical interpretation of the electrocardiogram and its subsequent filing in the clinical record. The built-in marker allows the equipment to synchronise events and annotations on the recording.
3. Technical Specifications
The following specifications correspond to the ECG thermal paper pack, reference 33026 (SKU GM33026).
Technical specifications
| Type | Pack |
|---|---|
| Width | 210 mm |
| Length | 140 mm |
| Sheets | 215 |
| Marker | Yes |
| Grid | White |
Compatible equipment (according to catalogue)
| ECG manufacturer | Compatible models |
|---|---|
| NIHON KOHDEN | Cardio-fax GEM/1250/1950, ECG-9010/9020/9022 |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 33026 |
| Sales unit | Box of 10 packs |
| Device type | Medical device (medical device) |
| Device class | I |
| CND | Z1302 |
| EAN | 8023279330267 |
4. Equivalences and Cross-References
Reference 33026 is the manufacturer’s official code for this ECG thermal paper pack of 210 x 140 mm with 215 sheets, marketed by Cahnos under SKU GM33026. The manufacturer declares its compatibility with Nihon Kohden Cardio-fax GEM/1250/1950 and ECG-9010/9020/9022 electrocardiographs. There is no official equivalence table validated by the manufacturer that cross-references this exact reference with consumables from other paper brands, so no 1:1 equivalences are indicated. For comparative purposes by category, Cahnos’ catalogue includes Nihon Kohden recording paper of the same sheet width (210 x 140 mm) that must always be checked against the electrocardiograph manual before replacement, as they may differ in the number of sheets, grid colour or the presence of a marker, aspects that affect the millimetric reading of the recording.
| Brand / Distributor | Reference | Format | Level | Observations |
|---|---|---|---|---|
| Cahnos (Nihon Kohden line) | 0590500 | 210 x 140 mm, 142 sheets, red grid | Comparable by category (not 1:1) | Intended for Cardiofax Q, ECG-9100/9110K/9130K; verify model and grid. |
| Cahnos (Nihon Kohden line) | 0553056 | 210 x 140 mm, 214 sheets, Z-fold | Comparable by category (not 1:1) | For Cardiofax M ECG-1350K / Cardiofax Q; confirm compatibility with the equipment. |
For any replacement in protocol or tender, consult Cahnos’ technical-commercial department to confirm exact compatibility with your electrocardiograph.
5. Selection tips and variants of interest
Before replenishing, check three data points on your electrocardiograph: the admissible sheet width (210 mm), the loading format (sheet pack versus continuous roll) and the type of grid required to interpret the traces (white in this reference). Also confirm the number of sheets (215) and the presence of a marker, and consult the equipment manual to validate the Nihon Kohden models indicated by the manufacturer. Do not confuse this consumable with formats from other families of different width, length or presentation: the 210 x 295 mm packs (ref. GM32966) are intended for equipment from other families, and the 210 mm x 30 m rolls with orange grid (ref. GM32967 and GM32992) correspond to equipment with continuous roll loading. For mixed equipment fleets, institutional orders or ongoing supply contracts, contact our technical-commercial department to confirm the exact reference and your quote under B2B conditions. Store the paper in a cool, dry place away from direct sunlight (5–40 °C) to preserve the sensitivity of the thermal layer and avoid trace fogging during its time in the clinical archive.