Description
1. Product Presentation
The thermal paper block for ECG for Elettronica Trentina Cardiette AR 1200 / AR 1200 ADV (ref. Cahnos 0553005-ET) is the recording consumable that keeps your electrocardiograph operational with maximum trace quality. Its sheet format of 60 × 75 mm, with 250 sheets per block and a pre-printed blue grid, ensures clear, stable and perfectly measurable electrocardiograms in every examination, whether in cardiology consultations, emergency departments, primary care or stress test units. The presentation in a box of 20 blocks facilitates planned replenishment and continuity of care for the service, with delivery in 24-72 h and special conditions for institutional purchases, maintenance contracts and tenders.
2. What this consumable is and how it works
This block uses direct thermal printing technology: the electrocardiograph’s thermal head transfers heat to the heat-sensitive layer of the paper and produces the trace instantly, without the need for ink, toner or ribbon, which reduces equipment maintenance and maintains consistent print quality throughout the entire block. The Z-fold (fanfold) format is placed directly in the equipment tray: each sheet is pre-folded to feed continuously and orderly, preventing jams and speeding up replenishment. The pre-printed blue grid acts as a millimetric measurement reference on the paper itself: it allows assessment of wave amplitude (mV), interval duration (PR, QT, RR) and recording speeds (mm/s), facilitating clinical interpretation of the ECG and its subsequent filing in the patient’s clinical record. The advance marker synchronises sheet cutting on each recording.
3. Technical Specifications
The following specifications correspond to the ECG thermal paper pad reference Cahnos 0553005-ET:
| Field | Specification |
|---|---|
| Brand / equipment family | Elettronica Trentina — Cardiette / Cardioline (Cardiette family) |
| Compatible models | Cardiette AR 1200 / AR 1200 ADV (OEM reference 66010039) |
| Reference Cahnos (SKU) | 0553005-ET |
| Manufacturer OEM reference | 66010039 (code not verifiable in public sources; confirm on the batch label) |
| Distribution code | 12464 (internal line numbering; not a manufacturer reference) |
| Sheet dimensions | 60 mm × 75 mm |
| Number of sheets | 250 sheets per pad |
| Grid colour | Blue |
| Format | Z-fold (fanfold) pad, with advance marker |
| Paper type | High-sensitivity thermal paper for thermal head (Quicktrace® HS type family) |
| Print technology | Direct thermal by printhead (no ink or toner) |
| Application | Medical recording: resting electrocardiography (ECG), stress tests and cardiac tracings |
| Commercial presentation | Box of 20 blocks |
| Regulatory classification | Class I medical device (with measuring function) · R.D. 1591/2009 · Directives 93/42/EEC and 2007/47/EC; verify CE marking of the batch |
| Trace shelf life | Approx. 5 years after printing under proper storage conditions |
| Storage | Cool, dry place (5–40 °C), away from direct sunlight and excessive humidity |
Reference verification note: the OEM code 66010039 and the internal code 12464 could not be verified in public sources. In public catalogues of paper manufacturers and authorised distribution, code 66010039 is associated with the folded pack of 120×100 mm × 300 sheets for Cardiette AR 1200, while the 60×75 mm × 250 sheets format with blue grid corresponds to OEM construction 66010040 of the DOT-Card 60 / AR 600 packaging. It is recommended to confirm both designations and the sheet format on the block label before formalising orders in tenders.
4. Equivalences and Cross-References
The 60×75 mm × 250 sheets format with blue grid (Z-fold with advance marker) is a very widespread standard in the Elettronica Trentina / Cardiette / Cardioline packaging. There is no official equivalence table published by the equipment manufacturer that cross-references the OEM code with other brands; the following references share the physical format dimension by dimension (measurements, sheets, blue grid and advance marker) and have been verified in public catalogues of their respective manufacturers or authorised distributors. They are classified as comparable by category and not interchangeable 1:1, and must be validated with the technical department before use in tenders.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GIMA S.p.A. (Italy) | ECG thermal chart 60×75×250 sheets, blue grid — compatible with Elettronica Trentina / Cardiette / Cardioline AR 600 Adv | 32977 (also CR32977) | Comparable by category (not interchangeable 1:1) | Same measurements, sheets, blue grid and advance indicators; phenol-free paper. Confirmed in official datasheets and authorised distribution. Heat-sensitive coating not confirmed as equivalent to the original. |
| FIDIM (repackaged, Italy) | Thermal chart 60×75×250 FF blue grid for ELETTRONICA TRENTINA / CARDIETTE / CARDIOLINE AR-600 Adv | CRCFET004 (presentations CRCFET004-3 / CRCFET004-5) | Comparable by category (not interchangeable 1:1) | Same dimensions 60×75×250 and blue grid; re-packer’s own code, without official validation from the equipment manufacturer; verify grammage and sensitivity against the head before replacing. Confirmed in authorised distribution. |
| EasyTrace® / DEAS S.r.l. (Italy) | ECG Paper AR600 / AR600 Adv Z-Fold 60×75×250 (associates original ref. 66010040) | ET6075P | Comparable by category (not interchangeable 1:1) | Same measurements and format; BPA-free, manufactured in Italy. Confirmed in the manufacturer’s catalogue (easytrace). OEM construction 66010040 corresponds to the DOT-Card 60 / AR 600 packaging; verify compatibility of the AR 1200 model with the equipment manual before replacing. |
| DH Medical (authorised distributor) | ECG Paper Cardioline AR 600Adv 60×75×250 sheets, blue grid (boxes of 25 blocks) | 400132977 | Comparable by category (not interchangeable 1:1) | Same measurements, sheets and blue grid; distributor’s own SKU and presentation in a box of 25 blocks versus the box of 20 for this reference. |
There is no equivalence table validated by the manufacturer (Elettronica Trentina / Cardioline) that cross-references reference 66010039 with other brands; the references in the table are comparative by category, not interchangeable 1:1, and must be confirmed with the technical department before use in tenders. Verification note: OEM reference 66010039 and code 12464 are not verifiable in public sources, and public catalogues associate 66010039 with the 120×100×300 pack (AR 1200) and 66010040 with the 60×75×250 format (AR 600 / DOT-Card 60); it is recommended to confirm both designations and the sheet format on the block label before formalising orders in tenders.
5. Selection tips and variants of interest
Before reordering, check three details on your electrocardiograph: the paper width (60 mm), the loading format (Z-fold pad or roll) and the grid colour you prefer for interpreting the traces (blue in this reference; the same family also includes versions with a red grid). Locate the OEM reference (66010039 according to the label on this line, or 66010040 on the original AR 600 packaging) on the pad’s own label or in the equipment manual to confirm exact compatibility with your Cardiette model. Variants from the same family in the Cahnos catalogue: 60×75×250-sheet pad with blue grid for Cardiette AR 600 / AR 600 ADV (ref. 0992043), 60×15 m roll with blue grid for AR 600 (ref. 0992024-ET), 120×100×300-sheet pad with blue grid for AR 1200 ADV / AR 1200 VIEW (ref. 0553005-CL) and 120×20 m roll with blue grid for the AR 1200 itself (refs. 0553151-ET / 0553151-CL). Do not confuse the formats: the 60 mm pad is not interchangeable with the 120 mm pack. Store the pad in a cool, dry place away from direct sunlight (5–40 °C), protected from humidity and heat sources, to preserve trace stability and prevent fogging of the thermosensitive layer; the recording permanence is approximately 5 years under proper storage conditions. For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm exact compatibility and obtain a formal quotation under volume B2B terms.




Reviews
There are no reviews yet.