Thermal ECG paper roll Fukuda Denshi FCP 145 U / FX 328 in 145 mm × 30 m format with high-contrast orange grid. Recording consumable for the FX series electrocardiographs, with OEM construction OP-341TE / OP31-34KE also documented for FX 326, FX 328U and the FD 31/34/35/36 series. Direct thermal printing via printhead, without ink or toner: sharp, stable traces with millimetric reading, with record durability of approximately 5 years under suitable storage conditions. Presentation in a box of 20 rolls, the most cost-effective option to ensure continuous replenishment in cardiology clinics, emergency departments and diagnostic units. Reference 0553021-FD; delivery 24-72 h.

International shipping. Import duties and taxes are payable by the recipient.

Reference
0553021-FD

Description

1. Product Presentation

The thermal paper roll Fukuda Denshi FCP 145 U / FX 328 (ref. Cahnos 0553021-FD) is the reference recording consumable for the FX series electrocardiographs from the Japanese manufacturer most widely installed in cardiology, emergency and general practice settings. Its 145 mm × 30 m format with orange grid guarantees clear, stable and perfectly measurable traces in every patient encounter, both in resting ECG and in stress tests. It is supplied in a box of 20 rolls: the replacement that ensures continuity of care and prevents service interruptions due to lack of paper. Immediate dispatch 24-72 h and formal quotation for institutional purchases and tenders.

2. Technical Explanation

This roll uses direct thermal printing technology: the electrocardiograph’s thermal printhead transfers heat to the paper’s heat-sensitive layer and produces the trace instantly, without the need for ink, toner or ribbon, which reduces recorder maintenance and maintains consistent print quality throughout the roll. The pre-printed orange grid acts as a millimetric measurement reference (recording paper with measuring function): it allows the amplitude of the waves to be assessed in millivolts, the duration of the intervals and the recording speeds in mm/s, facilitating clinical interpretation of the electrocardiogram and subsequent filing of the document in the patient’s clinical record. The 30-metre length offers a high level of autonomy for continuous recording. Loading the roll requires no prior configuration: simply orient the heat-sensitive side according to the equipment instructions.

3. Technical Specifications

Specification Technical data
Brand / compatible system Fukuda Denshi — FCP 145 U / FX 328 electrocardiographs (FX series)
Reference Cahnos (SKU) 0553021-FD
Technical line reference 0553021 – 9341
Manufacturer OEM reference OP-341TE / OP31-34KE (documented for FX 326 / FX 328 / FX 328U and FD 31/34/35/36 series)
Roll dimensions 145 mm (width) × 30 m (length)
Grid colour Orange
Paper type High-sensitivity thermal paper
Print technology Direct thermal printhead (no ink, toner or ribbon)
Commercial presentation Box of 20 rolls
Application Electrocardiography (ECG), stress tests and medical recording
Use Single-use consumable
Regulatory classification Medical device Class I (with measuring function) · CE
Trace shelf life Approx. 5 years after printing under proper storage conditions
Storage 5 °C to 40 °C, cool and dry place, without direct sunlight or excess humidity

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer Fukuda Denshi for this consumable. The OEM reference OP-341TE / OP31-34KE is the official construction for the family and is consistently confirmed in catalogues from paper manufacturers and authorised distributors (EasyTrace/Deas, Quality Chart Paper, Lessa) for the FX 326, FX 328 models and the FD 31/34/35/36 series. The 145 mm × 30 m format is a standard shared by equipment from several manufacturers; the following references have been checked against catalogues from manufacturers or authorised distributors and are classified as comparable by category, not interchangeable 1:1 without prior verification of the grid colour, length and core diameter.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
EasyTrace® (Deas S.r.l., Italy) ECG Recording Paper Pack · OP-31/34KE · FD34 / FD35 / FD36 / FX326 / FX328 FUD14530/1A2 Comparable by category (not interchangeable 1:1) Same 145 mm × 30 m format and same target printer (expressly includes FX 328), confirmed in the brand’s official catalogue. Supplied in a box of 5 rolls and grid colour not specified in the official datasheet: confirm before replacing.
Lessa / AB Medica Group (Spain) FUKUDA DENSHI · FD 31/34/35/36 / FX326 / FX328 · OEM OP31/34KE 1014405 (REF 300521) Comparable by category (not interchangeable 1:1) Same OEM OP31/34KE and same target machines, but 144 mm × 30 m and RED grid (not orange); archival legibility declared as 12 years by the paper manufacturer. Verify colour and grammage before replacing.
Quality Chart Paper (USA) FUKUDA DENSHI FD31-FD36 / FX326 / FX328 · OP-31 / OP-341TE FUD14530/1A2 Comparable by category (not interchangeable 1:1) 145 mm × 30 m for the same equipment family, but with RED grid (spool) and packs of 5/10 rolls. Not interchangeable without verifying the colour accepted by the equipment.
Nihon Kohden (equipment manufacturer) Cardiofax ECG Paper · OEM MS145-3 MS145-3 (eq. TecnoCarta RM3714503016IFU) Comparable by category (not interchangeable 1:1) Roll of ≈145 mm × 30 m with green grid for Cardiofax 5303/5403 (Beck-Lee, TecnoCarta). Same thermal printing system, but validated for another equipment family: confirm on the FX 328.
DH Material Médico (authorised distributor) ECG paper Fukuda Denshi 145 × 30 mm 400132994 Comparable by category (not interchangeable 1:1) Orange grid and box of 10 rolls; compatibility declared in catalogue with OP/358TE, FCP/131, FX3010, FX3101 and FX-8822 (a different family from the FX 328). Verify the exact equipment model before replacing.

The code 9341 accompanying this reference could not be verified in public sources and should be interpreted as an internal code of the distribution line; the official code for the family is OP-341TE / OP31-34KE. There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender.

5. Selection tips and variants of interest

Width and length: verify that your electrocardiograph’s printer supports rolls of 145 mm width and 30 m length; this is the format of the FX series (FX 302, FX 326, FX 328, FX 328U) and the FD 31/34/35/36 series. Also check the core diameter before replacing the consumable.

Grid colour: this datasheet corresponds to an orange grid. In the same 145 × 30 m format there are versions with a green grid (e.g. ref. Cahnos 0615018 for FX 326) and with a red grid (Lessa 1014405, Quality Chart Paper FUD14530/1A2); they are not interchangeable without prior verification on the equipment, since the colour affects the millimetric reading of the recording.

Variants of the same family in Cahnos: opaque roll 145 mm × 30 m with green grid for FX 326 (ref. 0615018, OEM OP-341TE / OP31-34KE, box of 20); rolls of 63 mm × 30 m for the single-channel Cardimax FCP-2101 / FX-7102 (refs. 0553110 and 0553132-FD); Z-fold blocks of 63 × 75 mm for FX-2201 / FCP-2155 / FCP-7101 (ref. 0553115).

Storage: store the rolls in a cool, dry place away from sunlight (5–40 °C) to preserve the sensitivity of the thermal layer and prevent tracing fogging. Record durability: approximately 5 years if the product instructions are followed.

Institutional purchases: for tenders, continuous supply contracts or large volumes, contact our technical-commercial department to confirm compatibility, exact reference and formalised quotation.

Additional information

Brand

Fukuda Denshi

Equipment model

FCP 145 U / FX 328 (FX series)

Manufacturer reference

0553021 – 9341

OEM reference

OP-341TE / OP31-34KE

Roll dimensions

145 mm × 30 m

Length

30 m per roll

Grid colour

Orange

Paper type

High-sensitivity thermal paper

Print technology

Direct thermal printhead (no ink, toner or ribbon)

Presentation

Box of 20 rolls

Compatibility

Fukuda Denshi FX 328; commonly used in FX 302, FX 326, FX 328U and FD 31/34/35/36 series (OEM construction OP-341TE / OP31-34KE)

Application

Electrocardiography (ECG), stress tests and medical recording

Use

Single-use consumable

Regulatory classification

Medical device Class I (with measuring function) · CE

Shelf life

Approx. 5 years after printing under proper storage conditions

Storage

5 °C to 40 °C, cool and dry place, without direct sunlight

Anchura

145 mm

Reviews