Description
1. Commercial Introduction
At Cahnos we offer the rechargeable 18 V and 0.7 Ah (700 mAh) nickel-cadmium (Ni-Cd) battery for the GE Healthcare Responder 1000 and SCP 840 defibrillators. It is the replacement part that keeps the resuscitation equipment operational when running in battery mode: rhythm monitoring, analysis, capacitor charging and delivery of the shock in emergency situations where every second counts. Available with delivery in 24/72 h for emergency departments, mobile intensive care units, ambulances, hospital wards and medical electronics maintenance programmes.
2. Technical Explanation
The GE Responder family defibrillators (formerly the Marquette / Hellige line) incorporate an internal rechargeable battery that powers the equipment in portable use and supports operation when there is no mains power. This battery supplies the nominal voltage of 18 V (15 cells of 1.2 V in AA format) and a capacity of 0.7 Ah (700 mAh), enough energy to maintain rhythm monitoring and provide the programmed shocks during patient care.
The pack fits into the equipment’s dedicated compartment with a positive locking connector; replacement is quick and requires no tools. The Ni-Cd chemistry of this replacement reproduces the original electrical behaviour of the equipment (voltage and discharge curve), so the defibrillator and its charger operate within the intended parameters. It is important to manage the depleted battery as waste electrical and electronic equipment (WEEE), as cadmium requires specialised treatment.
3. Technical Specifications
Data cross-checked against the distribution technical data sheet for the same code (88888235) and against market cross-references.
| Parameter | Specification |
| Reference Cahnos (code) | 88888235 |
| Manufacturer reference replaced | GE 20510002 (also cited 15N-800AA and 92916531) |
| Product type | Rechargeable replacement battery for defibrillator |
| Nominal voltage | 18 V (15 cells × 1.2 V) |
| Capacity | 0.7 Ah (700 mAh) |
| Energy | ≈ 12.6 Wh |
| Technology | Ni-Cd (nickel-cadmium), AA-format cells |
| Compatibility | GE Responder 1000 and SCP 840 (also documented for Responder 1100 and SCP 912) |
| Approx. dimensions | 113.6 × 28.4 × 50.5 mm |
| Approx. weight | 0.33 kg |
| Application | Power supply in portable mode and defibrillation discharge |
| Presentation | Unit |
| Use | Rechargeable; periodic replacement in preventive maintenance |
4. Equivalences and Cross-References
Note on the code: the GE 20510002 reference is the original equipment part that this battery replaces and it appears consistently in authorised distribution sources (e.g. the data sheet for the same code 88888235 from distributor VLAD) alongside the cross-references 15N-800AA and 92916531, cited by multiple medical battery suppliers for the Responder 1000/1100 and SCP 840/912 family.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| GE Healthcare | Original battery for Responder 1000 / SCP 840 defibrillator | 20510002 | Comparable by category (not interchangeable 1:1) | Original equipment part replaced by this spare: same 18 V voltage, same Ni-Cd chemistry and same 0.7 Ah capacity. Conservative labelling as this is a comparison between manufacturers; validate the connector fit against the original batch. |
| GE Healthcare | Original battery for Responder 1000 / 1100 and SCP 840 / 912 | 15N-800AA | Comparable by category (not interchangeable 1:1) | Cross-reference consistently cited alongside 20510002 in authorised distribution compatibility tables; same dimensions and voltage. Confirm the equipment batch label. |
| GE Healthcare | Original battery for Responder 1000 / 1100 | 92916531 | Comparable by category (not interchangeable 1:1) | Cited alongside 20510002 and 15N-800AA in multiple compatibility tables for the Responder family; verify against the equipment label. |
| Cameron Sino | Replacement battery for GE Responder 1000 / 1100, SCP 840 / 912 | CS-GER100MD | Comparable by category (not interchangeable 1:1) | Ni-MH chemistry and 800 mAh (0.8 Ah) capacity versus the original Ni-Cd 0.7 Ah; approximate dimensions 114 × 51.8 × 28.5 mm. Verify the compatibility of the equipment charger before replacing. |
There is no equivalence table validated by GE Healthcare that cross-references this reference with third parties; the references indicated have been verified against authorised distribution sources and specialised catalogues, but 1:1 replacement must be validated field by field (voltage, chemistry, capacity, dimensions and connector type). Consult the technical department before use in tendering.
5. Selection tips and variants of interest
- Verify the exact model of the equipment: this battery is the one indicated for Responder 1000 and SCP 840; in distribution it is also documented for Responder 1100 and SCP 912.
- Check the reference printed on the equipment’s original battery (20510002, 15N-800AA or 92916531): if it matches, this replacement is the direct substitute.
- Do not confuse it with other GE family batteries of different voltage or capacity (e.g. those for Responder 2000/3000 equipment or those for Cardiosmart / MAC electrocardiographs).
- After installation, perform a full charge cycle before putting the equipment into service and check the battery indicator.
- Environmental management: take the depleted Ni-Cd battery to a specialised collection point (WEEE); do not place it in the general waste container.
- For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, exact reference and formal quotation.