Description
1. Professional energy for your CU Medical defibrillator
At Cahnos we offer you the rechargeable battery, 14.8 V and 3.1 Ah for the defibrillator/monitor CU Medical Lifegain CU-HD1 (referred to in our commercial range as MRF HD1), identified in our catalogue under reference 88889033. This is the spare part that will restore the equipment to full operational status, eliminate battery warnings from the self-test and keep the defibrillator ready for use in any critical environment: hospital emergency departments, ambulances, advanced life support, sports medicine and professional defibrillation.
The most widely documented original factory reference for this battery is CUBTM101A, consistently confirmed across multiple specialist distribution sources (Kingsener, BatteryMall, Akkushop, Ultragreen Battery, PanSW Medical) and in the catalogue information published by CU Medical for the LiFEGAIN CU-HD1.
2. Technical explanation: how this battery works
The LiFEGAIN CU-HD1 is a professional defibrillator/monitor that supports defibrillation in AED and manual modes, synchronised cardioversion, transcutaneous pacing, SpO₂ monitoring and 12-lead ECG. During use, the battery powers the rhythm analysis electronics, the display, the instruction speaker, the pacemaker and the capacitor charge/discharge stage that delivers biphasic therapy.
This battery uses rechargeable lithium polymer (LiPo) chemistry: it offers high energy density in a lightweight format (≈45.9 Wh), low self-discharge and stable response under current demand. While the equipment is at rest, the internal self-test periodically checks the state of charge; as it approaches depletion, the defibrillator warns to proceed with recharging or replacement. Installation is direct in the equipment compartment, without tools.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88889033 |
| Original reference (manufacturer) | CUBTM101A (original battery for the LiFEGAIN CU-HD1); associated distribution code: 110710-O |
| Type / technology | Rechargeable lithium polymer (LiPo) battery |
| Nominal voltage | 14.8 V |
| Nominal capacity | 3.1 Ah (3100 mAh) |
| Nominal energy | ≈ 45.9 Wh |
| Approximate dimensions | ≈ 169 × 104 × 50 mm (depending on distribution; verify compartment) |
| Approximate weight | ≈ 0.59 – 0.69 kg |
| Rechargeable | Yes |
| Compatibility | CU Medical LiFEGAIN CU-HD1 (defibrillator/monitor), CU-HD1 SP variant with external paddles; Cahnos MRF HD1 family |
| Supported functions | AED, manual defibrillation, synchronised cardioversion, transcutaneous pacemaker, SpO₂, ECG |
| Installation | Direct replacement in the equipment compartment, without tools |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations (regulated lithium transport) |
Technical note: the voltage, capacity and chemistry data (14.8 V / 3.1 Ah / LiPo) correspond to the original reference CUBTM101A documented for the CU-HD1; confirm the code printed on the removed battery before placing the order.
4. Equivalences and Cross-References
The original factory reference for this battery is CUBTM101A, the code under which the 14.8 V / 3.1 Ah pack is documented for the LiFEGAIN CU-HD1 defibrillator/monitor in specialist distribution sources and in CU Medical’s catalogue information. CU Medical does not publish an official equivalence table authorising third-party batteries for this equipment; the listed alternatives share the same type (rechargeable defibrillator battery) and are classified as comparable by category, not 1:1 interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| CU Medical (equipment manufacturer) | Original battery LiFEGAIN CU-HD1 / i-PAD CU-HD1 | CUBTM101A | Exact reference equivalence (same manufacturer) | This is the original battery reproduced in this datasheet: rechargeable LiPo, 14.8 V / 3.1 Ah (3100 mAh, ≈45.9 Wh), format ≈169 × 104 × 50 mm. Consistently documented in specialist distribution and in CU Medical’s catalogue for the CU-HD1. |
| Kingsener | Aftermarket replacement for CU Medical i-PAD CU-HD1 | Kingsener CUBTM101A | Comparable by category (not interchangeable 1:1) | Third-party replacement declaring 14.8 V / 3100 mAh and compatibility with the CU-HD1; declared chemistry Li-ion (verify parity with LiPo), connector, dimensions (≈169 × 104 × 50 mm) and compartment housing before replacement. |
| CU Medical (reported variant) | Higher capacity battery reported for the same CU-HD1 | CUBTM102A | Not verified | Reference cited in distribution channels linked to the same equipment, but with contradictory specifications between sources (14.8 V / 3.1 Ah according to some; 14.4 V / 5.0 Ah / 72 Wh according to others). Pending confirmation with the manufacturer before considering its use. |
There is no equivalence table validated by the manufacturer (CU Medical) that cross-references the CUBTM101A reference with third-party batteries; consult the technical department before use in tenders. Before accepting any alternative battery, each of the following must be verified one by one: voltage (14.8 V), capacity (3.1 Ah), chemistry (rechargeable LiPo), pack dimensions and compartment connector. Batteries from other defibrillators on the market (e.g. Philips HeartStart FR3 989803150161, ZOLL AED Pro 8000-0860-01, Defibtech DBP-1400/DBP-2800 or Welch Allyn 1852) share the same type but are not interchangeable with the CU-HD1 due to proprietary connector, voltage and management electronics.
5. Selection tips and variants of interest
Identify the exact model: this battery corresponds to the CU Medical LiFEGAIN CU-HD1 defibrillator/monitor (MRF HD1 family) and its CU-HD1 SP variant. It is not compatible with the CU Medical i-PAD NF1200 AED (MRF family), which uses the original non-rechargeable CUSA0601F battery, 12 V / 4.2 Ah.
Verify the printed reference: before ordering, confirm on the removed battery the code CUBTM101A, the voltage (14.8 V) and the capacity (3.1 Ah). If your equipment works with another pack, do not force the replacement.
Rechargeable battery maintenance: as it is LiPo, follow the equipment manufacturer’s guidelines; do not leave the battery unused for long periods without checking its charge level and recharge it periodically according to the cycle indicated in the CU-HD1 documentation.
Accessories: also check the condition and expiry date of the defibrillation electrodes (adult and paediatric) and the 12-lead ECG cable to keep the point of care fully operational.
Recycling: dispose of the exhausted battery at the authorised WEEE collection points in accordance with current regulations. For volume orders or tenders, contact the technical department at Cahnos stating the model, the equipment serial number and the reference of the installed battery; we will confirm compatibility before placing the order.