We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Lithium Battery 12V 7500mAh for Defibrillator Cardiac Science Powerheart G3 / G3 Plus – Ref. 9146-202/302 (Non-Rechargeable) | Original Cardiac Science · SKU 88888768

664,00 €

Original 12V 7500mAh lithium battery for Cardiac Science Powerheart G3 / G3 Plus defibrillator (Ref. 9146-202/302). Primary non-rechargeable Li-SO2 pack, with Intellisense chip, daily device self-test and up to 4 years of service life. Tool-free direct replacement for models 9146, 9300A/9300E and 9390A/9390E. Traceable replacement solution for hospitals, ambulances, AED centres and tenders. SKU Cahnos 88888768, price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888768

Description

1. Original backup power for your Cardiac Science defibrillator

Keep your defibrillator always ready for action with the original Cardiac Science battery, 12 V and 7500 mAh, supplied under the reference Cahnos 88888768, corresponding to factory code 9146-202/302. This is the OEM replacement for the Powerheart G3 / G3 Plus and G3 Elite equipment family, with primary lithium chemistry (Li-SO2), a shelf life of up to 4 years and the Intellisense chip that verifies battery status in the defibrillator’s daily self-test.

A direct, traceable replacement solution for hospitals, ambulances, workplaces, schools and public spaces with AEDs, backed by Cahnos technical-commercial support for medical electronics services, equipment fleets and tenders.

2. Technical explanation: how this battery works

The Cardiac Science Powerheart G3 / G3 Plus defibrillators (model 9146; series 9300A/9300E and 9390A/9390E) are automated external defibrillation devices that analyse cardiac rhythm and deliver the shock semiautomatically or automatically. The original battery 9146-202/302 is a non-rechargeable primary lithium pack (Li-SO2, sulphur dioxide) of 12 V and 7.5 Ah (90 Wh) that supplies the energy for analysis, monitoring and discharge throughout its service life.

Unlike a rechargeable battery, this battery cannot be recharged: it must be replaced with a new unit when the device indicates so. Its built-in Intellisense chip communicates the battery status, installation date and end of service life to the defibrillator, so that the daily self-test confirms the device is operational, with stable performance over a wide temperature range (from -20 °C to 55 °C according to manufacturer documentation). Installation takes seconds, by fitting the battery into the compartment without tools.

3. Technical Specifications

Parameter Detail
Reference Cahnos (SKU) 88888768
Original manufacturer reference 9146 (designations of the same pack: 9146-001, 9146-002, 9146-102, 9146-202, 9146-302 and 9146-ABE)
Product type Original replacement battery (OEM) for defibrillator
Technology / chemistry Primary lithium (sulphur dioxide, Li-SO2), non-rechargeable
Nominal voltage 12 V
Capacity 7500 mAh (7.5 Ah)
Energy 90 Wh (12 V × 7.5 Ah)
Service life (standby) Up to 4 years from installation
Manufacture expiry Approx. 5 years from the date of manufacture
Compatibility Cardiac Science Powerheart G3, G3 Plus and G3 Elite: models 9146 and series 9300A/9300E, 9390A/9390E (units shipped after April 2004, according to manufacturer documentation)
Management system Intellisense chip: daily self-test of the equipment and battery status reading
Temperature range From -20 °C to 55 °C (according to the manufacturer’s documentation)
Installation Direct replacement in the compartment, no tools required
Rechargeable No (single-use primary battery; do not connect to a charger)
Presentation 1 unit
Recycling Do not dispose of as municipal waste; recycle in accordance with RAEE/WEEE regulations

The main specifications (12 V, 7.5 Ah / 7500 mAh, 90 Wh, Li-SO2 chemistry, 4-year service life) come from the manufacturer’s technical documentation and authorised distribution of the original 9146 replacement; always confirm the reference stamped on the depleted battery before replacing.

4. Equivalences and Cross-References

The original reference 9146-202/302 corresponds to the primary lithium battery that Cardiac Science fits in the Powerheart G3 / G3 Plus family. Cardiac Science does not publish an official equivalence table authorising third-party batteries; the cited OEM designations are alternative numbers for the same factory pack, while the replacement references indicated below share chemistry (Li-SO2), voltage (12 V) and capacity (7.5 Ah) and are classified as comparable by category, not 1:1 interchangeable, and must be validated on a case-by-case basis (reading chip, connector and dimensions) before replacement.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Cardiac Science (factory designations) Powerheart G3 / G3 Plus / G3 Elite (9146; 9300A/9300E, 9390A/9390E) 9146 = 9146-001 = 9146-002 = 9146-102 = 9146-202 = 9146-302 (9146-ABE) Exact reference equivalence (same manufacturer) OEM numbers for the same primary lithium Li-SO2 pack, 12 V, 7.5 Ah (90 Wh), yellow casing with Intellisense chip; same performance and service life (4 years in service / 5 years shelf life); consistently confirmed in authorised distribution. Verify the exact variant printed on the label of the installed battery.
BBM Battery Replacement battery for Powerheart AED G3 / G3 Plus 7064 Comparable by category (not interchangeable 1:1) Lithium (Li-SO2), 12 V, 7500 mAh, non-rechargeable; replaces OEM 9146-102, 9146-202 and 9146-302; certified by Health Canada. Different replacement manufacturer (not original Cardiac Science); verify Intellisense chip reading, connector and dimensions against the device. Confirmed in distributor datasheet.
AMCO / Medical Battery Pros Powerheart G3 / G3 Plus replacement battery AM9146-2 (9146-2) Comparable by category (not interchangeable 1:1) Lithium (Li-SO2), 12 V, 7.5 Ah, non-rechargeable, yellow casing; crosses with 9146-001, 9146-002, 9146-102, 9146-202, 9146-302, 9142, 9143 and the 9300A/9300E series; approximate dimensions 233 × 52 × 70 mm. Different replacement manufacturer (not original Cardiac Science); validate reading chip, connector and dimensions before replacing. Confirmed in distributor datasheet.

There is no equivalence table validated by the manufacturer (Cardiac Science) authorising third-party batteries for reference 9146; the cross-references indicated come from replacement manufacturers and specialised distributors, so it is recommended to consult with the technical department before use in tenders.

5. Selection tips and variants of interest

  • Confirm the device model: this battery corresponds to the Cardiac Science Powerheart G3 / G3 Plus / G3 Elite defibrillator (model 9146; series 9300A/9300E and 9390A/9390E). Check the reference stamped on the depleted battery (9146-001, 9146-002, 9146-102, 9146-202, 9146-302 or 9146-ABE) before ordering.
  • Non-rechargeable: this is a single-use primary lithium battery. Do not connect it to any charger or attempt to recondition it; replace it when the device indicates low battery or when it approaches the end of its service life (4 years from installation).
  • Symptoms of depletion: daily self-test with failure or low battery warning, reduced analysis time or service indicator illuminated indicate that the pack must be replaced to keep the device operational in emergencies.
  • Storage: store the battery in a dry place, at room temperature and inside its original packaging until installation; respect the factory expiry date (approx. 5 years).
  • Environmental management: at the end of its service life, dispose of the battery at an authorised WEEE collection point; never discard it as household waste or incinerate it.
  • Variants of the same family at Cahnos: for the Cardiac Science Powerheart 9145 defibrillator, there is a lithium battery 12 V / 7.5 Ah (Ref. Cahnos 88888683) and for the Powerheart G5, Ref. 88881203. Do not interchange these references between models without technical validation: each device requires its specific pack.
  • Institutional orders: for consortia, tenders or maintenance contracts, contact the technical-commercial department of Cahnos to confirm exact compatibility with your batch of defibrillators and obtain a formalised quotation with special conditions for volume.

Additional information

Manufacturer reference

9146 (designations of the same pack: 9146-001, 9146-002, 9146-102, 9146-202, 9146-302 and 9146-ABE)

Product type

Original replacement battery (OEM) for defibrillator

Technology

Primary lithium (sulphur dioxide, Li-SO2), non-rechargeable

Nominal voltage

12 V

Capacity

7500 mAh (7.5 Ah)

Energy

90 Wh (12 V x 7.5 Ah)

Rechargeable

No (single-use primary battery)

Service life

Up to 4 years from installation

Manufacture expiry

Approx. 5 years from the date of manufacture

Compatibility

Cardiac Science Powerheart G3, G3 Plus and G3 Elite: models 9146 and series 9300A/9300E, 9390A/9390E

Management system

Intellisense chip: daily self-test of the equipment and battery status reading

Temperature range

-20 °C to 55 °C (according to manufacturer's documentation)

Installation

Direct replacement in the compartment, no tools required

Recycling

Manage in accordance with WEEE regulations