Description
1. Commercial Introduction
The ZOLL CPR Uni-padz electrode set (Ref. 8900-000260) is the official replacement for the automatic external defibrillators ZOLL AED 3 and AED 3 BLS of the X series. Its great advantage over other consumables is its truly universal nature: with the same pair of pads you can treat an adult or a child patient, without needing to purchase or store two different references. Designed for emergency services, ambulances, companies, sports centres, schools, hospitals and public access defibrillation programmes, it also offers an installed service life of up to 5 years, which reduces the total cost of ownership and maintenance tasks for your fleet.
2. Technical Explanation
The CPR Uni-padz electrodes are pre-connected multifunction pads that combine defibrillation with cardiopulmonary resuscitation feedback. They incorporate ZOLL’s Real CPR Help® technology: an integrated sensor detects chest compression activity and transmits frequency and depth data to the AED 3, so the device provides real-time voice, text and visual prompts (for example, “push harder” when depth is insufficient). For paediatric care, no other pad set is needed: the electrodes are repositioned according to the diagram on the packaging (anterior-posterior placement) and paediatric rescue mode is activated with a single button on the device. Each set is supplied with an attached rescue kit, which helps prepare the patient in the shortest possible time: scissors for cutting clothing, latex-free gloves and a barrier face mask for rescuer protection, a paper wipe to ensure dry electrode contact, a razor to remove hair and a cleaning wipe.
3. Technical Specifications
| Characteristic | Detail |
| Manufacturer | ZOLL Medical Corporation |
| Official manufacturer reference | 8900-000260 (CPR Uni-padz®) |
| SKU Cahnos | 8900-000260 (matches the official part number of ZOLL) |
| Product type | Universal adult/paediatric multifunction electrodes with CPR feedback |
| Population | Adults and paediatric patients (paediatric rescue mode by repositioning the pads) |
| Compatibility | ZOLL AED 3 and ZOLL AED 3 BLS (X series family) |
| Technology | Real CPR Help® (rate and depth of compressions) in adult patients |
| Adult placement | Anterior surface: upper right chest and lower left |
| Paediatric placement | Anterior-posterior position (frontal and dorsal), according to the diagram on the packaging |
| Shelf life | Up to 5 years of installed life from the date of manufacture |
| Attached rescue kit | Scissors, latex-free gloves, barrier face mask, paper towel, razor and cleansing wipe |
| Use | Single-use, disposable, non-sterile |
| Presentation | 1 set of electrodes (pair) with attached rescue kit |
Technical note: always check the expiry date printed on the packaging and install new electrodes before the device indicates it. The 5-year service life corresponds to the manufacturer’s official specification for storage and installed use.
4. Equivalences and Cross-References
Exact reference equivalence: the Cahnos SKU (8900-000260) literally matches the official part number of ZOLL Medical (Part # 8900-000260, confirmed in the official accessories catalogue for AED 3 and on the manufacturer’s website), so it is the same item, without an intermediate distributor code.
Official successor within the same family: according to the ZOLL technical bulletin and authorised distributors, production of reference 8900-000260 has ceased and it has been replaced by the CPR Uni-padz III, ref. 8900-000280 / 8900-000280-01, for the same AED 3 device (non-BLS models). It is recommended to confirm with the Cahnos technical department the software version and exact model of your device before changing sub-reference.
| Reference | Product | Related items |
| 8900-000260 | CPR Uni-padz universal adult/paediatric for AED 3 (this product) | Original reference ZOLL |
| 8900-000280 / 8900-000280-01 | CPR Uni-padz III universal adult/paediatric for AED 3 | Official successor replacing the 8900-000260 |
| 8900-0800-01 | Adult electrode CPR-D•PADZ with Real CPR Help (1 pair) — SKU Cahnos 1351002 | Comparable by category; connector for the AED Plus/Pro/X/R family, not valid for AED 3 |
| 8900-0801 / 8900-0802-01 | Stat Padz II adult electrode (1 pair / box of 12 pairs) for AED Plus/PRO | Comparable by category; no CPR sensor |
| 8900-0810-01 | Pedi Padz II paediatric electrode (1 pair) for AED Plus/PRO | Comparable by category; for patients under 25 kg |
There is no official equivalence table validated by the manufacturer that would allow this electrode to be replaced by pads from other AED brands (e.g. Philips HeartStart or Stryker/Physio-Control LIFEPAK): the connector and feedback system are proprietary to ZOLL. Any comparison with other manufacturers should be understood as comparable at category level, not interchangeable 1:1, and must be confirmed with the technical department before use in tenders or maintenance contracts.
5. Selection tips and variants of interest
- If your device is a ZOLL AED 3 or AED 3 BLS, this electrode set (8900-000260) is the indicated official replacement; do not use pads from the AED Plus/PRO families or X/R monitoring series, as their connectors are not compatible.
- Do you work with multiple defibrillation points? Always keep a spare set per device inside the case or support, along with a reserve battery (Ref. 8000-000696) and, for transport, the standard ZOLL AED 3 case (Ref. 8000-001250).
- Manage stock rotation by expiry date: the 5-year service life allows multi-year purchasing planning, but the date printed on the packaging must be checked and the set replaced after use or expiry.
- For children, remember the procedure: reposition the pads in the anterior-posterior position and select paediatric rescue mode on the device; you do not need to purchase a separate child electrode.
- If your fleet also includes AED Plus or AED Pro, the corresponding replacements are Stat Padz II (8900-0801) for adults and Pedi Padz II (8900-0810-01) for paediatrics.