Description
1. Introduction
Ensure your defibrillator remains operational with the genuine ZOLL Stat-Padz II replacement in an institutional pack of 12 pairs (ref. 8900-0802-01). This is the adult electrode solution recommended by the manufacturer for the ZOLL AED Plus, AED Pro, AED 3 and AED 3 BLS devices, both in public access programmes and professional emergency settings. This multipack keeps a complete AED fleet operational with a single order, ensuring long-term replacement and an optimised cost per pair.
Identification note: the factory reference 8900-0802-01 corresponds to the adult electrode Stat-Padz II. The Pedi-Padz II model is the paediatric variant and has its own factory code (8900-0810-01). If your previous records associated them, this data sheet corrects that assignment based on the manufacturer’s official documentation.
2. Technical explanation
The Stat-Padz II HVP electrodes are two-piece multifunction electrodes (sternum and apex) that allow rhythm analysis, rectilinear biphasic defibrillation and ECG monitoring through a single pad connected to the device via a proprietary ZOLL connector. Their HVP (high-performance polymer hydrogel) gel ensures stable adhesion, low contact impedance and reliable ECG signal quality, even in patients with a wet or hairy chest. The pre-connected connector minimises preparation time: remove the protective cover, place the pad following the diagrams on the packaging, and the device is ready for analysis and discharge. As a single-use product, it must be replaced after each intervention or upon reaching its expiry date.
3. Technical Specifications
| Field | Specification |
|---|---|
| Manufacturer reference | 8900-0802-01 (ZOLL Medical Corporation) |
| Electrode type | Adult multifunction Stat-Padz II HVP (2 pieces: sternum and apex) |
| Presentation | Box of 12 pairs |
| Population | Adults and children over 8 years (approx. from 55 lb / 25 kg) |
| Gel material | HVP (high-viscosity polymer hydrogel) |
| Compatibility | ZOLL AED Plus, AED Pro, AED 3 and AED 3 BLS |
| Shelf life | Up to 2 years from the date of manufacture (18–24 months depending on batch, guaranteed by ZOLL) |
| Connector | Proprietary ZOLL, pre-connected |
| Use | Single-use, disposable |
| Sterility | Non-sterile |
4. Equivalences and Cross-References
There is no equivalence table validated by ZOLL that allows replacing ref. 8900-0802-01 with electrodes from other manufacturers: the connector and monitoring system are proprietary to ZOLL, so any comparison with other brands should be understood as comparable at category level, not interchangeable 1:1 (connector, geometry, gel and analysis algorithm differ). Any cross-reference must be confirmed with the technical department before use in tenders.
| Reference | Product | Related items |
|---|---|---|
| 8900-0801 / 8900-0801-01 | Stat-Padz II adult electrode (1 pair) for AED Plus / AED Pro | Direct equivalent, unit format |
| 8900-0810-01 | Pedi-Padz II paediatric electrode (1 pair) | Complementary, patients \u003C 8 years / \u003C 25 kg |
| 8900-0800-01 | CPR-D-Padz adult single piece with Real CPR Help | Alternative with integrated CPR sensor |
| 8900-000260 | CPR Uni-padz universal adult/paediatric for AED 3 | CPR family, AED 3 connector |
| 8900-00861-01 | Pedi-Padz II electrodes for ZOLL TRAINER 2 | Exclusive use in training |
5. Selection tips and variants of interest
- If your device is a ZOLL AED Plus or AED Pro and you serve the general adult population, this multipack of 12 pairs is the highest-volume replacement with the best cost per pair.
- For single-unit supply or individual defibrillation points, consider the 1 pair (8900-0801) pack, which requires a lower initial outlay.
- For centres with nurseries, schools or frequent paediatric care, combine with the Pedi-Padz II (8900-0810-01): the AED Plus/AED Pro automatically switch to paediatric energy levels when this electrode is detected.
- If your CPR programme requires real-time compression guidance, the recommended replacement is the CPR-D-Padz (8900-0800-01) with Real CPR Help.
- Manage stock rotation by expiry date: shelf life of up to 2 years, but the date printed on each package must be checked and the electrode replaced after use or upon expiry.
- Consult Cahnos’s technical department to confirm exact compatibility with your defibrillator model before placing large-volume orders or tenders.





Reviews
There are no reviews yet.