Description
Ensure the operability of your emergency equipment with the original ZOLL replacement multifunction electrodes for adults: the Stat-Padz II (ref. 8900-0801, official construction 8900-0801-01) in a 1 pair format. Designed specifically for ZOLL AED Plus and AED Pro defibrillators, this electrode ensures reliable performance in the treatment of cardiac arrest and complies with current resuscitation protocols. An essential solution for emergency services, sports centres, companies with AEDs and any defibrillation point requiring rapid replacement and certified quality.
Identification note: the reference 8900-0801 corresponds to the adult Stat-Padz II electrode. The Pedi Padz II model is the paediatric variant and has its own factory code (8900-0810-01). This datasheet corrects that assignment based on the manufacturer’s official documentation to avoid confusion when purchasing.
Technical explanation
The Stat-Padz II HVP electrodes are two-piece multifunction electrodes (sternum and apex) that, connected to the defibrillator via the proprietary ZOLL pre-connected connector (Pre-Connect system), allow three functions to be performed with a single pad: cardiac rhythm analysis, biphasic defibrillation and ECG monitoring. Their HVP gel (high-performance polymer hydrogel) ensures stable adhesion, low contact impedance and reliable signal quality even on wet or hairy chests. Application time is minimised: the protective liner is removed, the electrodes are placed following the anatomical diagrams on the packaging and the device is ready for analysis and shock delivery. They are single-use products: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.
Technical specifications
| Field | Specification |
| Manufacturer reference | 8900-0801-01 (ZOLL Medical Corporation); SKU Cahnos: 8900-0801 |
| Electrode type | Adult multifunction Stat-Padz II HVP (2 pieces: sternum and apex) |
| Presentation | 1 pair (2 electrodes) |
| Population | Adults and children over 8 years (approx. from 55 lb / 25 kg) |
| Gel material | HVP (high-performance polymeric hydrogel) |
| Compatibility | ZOLL AED Plus and AED Pro (according to official ZOLL catalogue; some distributors also list AED 3, pending technical confirmation) |
| Connector | Proprietary ZOLL, pre-connected |
| Use | Single-use, disposable |
| Sterility | Non-sterile |
| Shelf life | 18-24 months from the date of manufacture (guaranteed by ZOLL; check date on packaging) |
Equivalences and cross-references
There is no equivalence table validated by ZOLL that allows replacing ref. 8900-0801 with electrodes from other manufacturers: the connector and monitoring system are proprietary to ZOLL, so any comparison with other brands should be understood as comparable at category level, not interchangeable 1:1 (they differ in connector, geometry, gel and analysis algorithm). Any cross-reference is pending confirmation with the technical department before use in tenders.
| Reference | Product | Related items |
| 8900-0801-01 | Stat-Padz II adult electrode (1 pair) for AED Plus / AED Pro | Same reference, official ZOLL construction |
| 8900-0802-01 | Stat-Padz II adult electrode, box of 12 pairs | Same electrode, multipack format |
| 8900-0810-01 | Pedi-Padz II paediatric electrode (1 pair) | Complementary, patients \u003C 8 years / \u003C 25 kg |
| 8900-0800-01 | CPR-D-Padz adult single piece with Real CPR Help | Alternative with integrated CPR sensor |
| 8900-000260 | CPR Uni-padz universal adult/paediatric for AED 3 | CPR family, AED 3 connector |
| 8900-0805-01 | Stat-Padz II electrodes for ZOLL TRAINER 2 (box of 6) | Exclusive use in training |
Selection tips and variants of interest
If your device is a ZOLL AED Plus or AED Pro and you treat the general adult population, this presentation of 1 pair (8900-0801) is ideal for equipping individual defibrillation points with unit replacement. For AED fleets or high-volume centres, consider the box of 12 pairs (8900-0802-01), with a better cost per pair. For centres with nurseries, schools or frequent paediatric care, combine with the Pedi-Padz II (8900-0810-01): the AED Plus/AED Pro automatically switch to paediatric energy levels when this electrode is detected. If your CPR programme requires real-time compression guidance, the recommended replacement is the CPR-D-Padz (8900-0800-01) with Real CPR Help. Manage stock rotation by expiry (18-24 months) and always replace the electrode after use or expiration. Consult with the Cahnos technical department to confirm exact compatibility with your model before placing large volume orders or tenders.