Description
1. Professional defibrillation kit: adult electrode ZOLL CPR-D•PADZ with rescue kit
The ZOLL CPR-D•PADZ adult kit (ref. 8900-0800-01) is the complete, ready-to-use solution that emergency services, ambulances, workplaces with an AED and hospital settings need in the event of cardiac arrest. It includes a pair of one-piece adult CPR-D•PADZ electrodes with ZOLL Real CPR Help® technology, together with a full rescue kit: protective face mask, scissors, disposable gloves, razor and wipes. A fast, hygienic and effective response in every intervention, backed by the manufacturer’s official replacement.
2. Technical explanation: Real CPR Help®, single-piece design and pre-connected connection
The CPR-D•PADZ electrodes incorporate ZOLL Real CPR Help® technology: an integrated sensor detects chest movement during compressions and transmits CPR rate and depth data to the defibrillator, allowing the device to provide voice prompts and an adaptive metronome in real time. In this way, the rescuer receives immediate feedback («push harder», «good compressions») without interrupting the manoeuvres. On compatible devices such as the X Series, the system adds the See-Thru CPR® function, which filters out the compression artefact to analyse the cardiac rhythm without pauses. Its one-piece design combines the anterior and posterior electrodes in a single element: remove the protective liner, place the assembly on the chest following the anatomical diagrams on the packaging, and the device is ready for analysis, defibrillation and monitoring. The proprietary ZOLL connector is pre-connected, minimising preparation time in an emergency.
3. Technical Specifications
| Field | Specification |
|---|---|
| Manufacturer | ZOLL Medical Corporation |
| Official manufacturer reference | 8900-0800-01 (CPR-D•PADZ®) |
| SKU Cahnos | 8900-0800-01 |
| Electrode type | Adult multifunction electrode, single-piece (anterior + posterior) with CPR sensor |
| Presentation | 1 pair (1 single piece with both electrodes) |
| Population | Adults and children over 8 years (approx. from 25 kg / 55 lb) |
| Technology | Real CPR Help® (compression rate and depth), adaptive metronome and See-Thru CPR® on compatible equipment |
| Compatibility | ZOLL AED Plus®, AED Pro®, AED 3®, AED 3 BLS®, R Series®, X Series® and Propaq MD® (M Series® and E Series® with CPR connector 8000-0370 on some models) |
| Rescue kit included | Barrier face mask, gloves, scissors, razor, wet wipe and dry wipe |
| Shelf life | Up to 5 years from date of manufacture (the longest on the market for disposable electrodes) |
| Storage | Long-lasting protective packaging type “armor pack”, suitable for defibrillator soft case |
| Use | Single-use, disposable, non-sterile |
| Regulatory registration | GUDID/FDA: 00847946000189 (version/model 8900-0800-01) |
Note: the range and conditions of use correspond to the manufacturer’s official specification. Always check the expiry date printed on the packaging and replace the electrode after use or upon expiry.
4. Equivalences and Cross-References
There is no official equivalence table validated by ZOLL that would allow the ref. 8900-0800-01 to be replaced by electrodes from other manufacturers: the CPR-D connector is a proprietary ZOLL system and compatibility must always be confirmed against the official technical data sheet and IFU. Any comparison with other brands (e.g. PRIMEDIC for HeartSave) should be understood as comparable at category level, not interchangeable 1:1, since the connector, geometry, sensor and algorithm differ. Within the ZOLL family itself, the related references are:
| Reference | Product | Related items |
|---|---|---|
| 8900-0801 / 8900-0801-01 | Stat-Padz II, adult electrode (1 pair) for AED Plus/AED Pro | Alternative without Real CPR Help sensor, lower cost per pair |
| 8900-0802-01 | Stat-Padz II, adult electrode (box of 12 pairs) | Same family, institutional multipack format |
| 8900-0810-01 | Pedi-Padz II, paediatric electrode (1 pair) | Complementary, population under 25 kg |
| 8900-000260 | CPR Uni-padz universal adult/paediatric for AED 3 | CPR family, AED 3 connector |
| 8900-0804-01 | CPR-D•PADZ training electrode for Trainer 2 simulator | Exclusive use in training, not clinical |
Any cross-reference with other manufacturers is pending confirmation with the Cahnos technical department before use in tenders.
5. Selection tips and variants of interest
- If your device is a ZOLL AED Plus or AED Pro and you want real-time CPR guidance, the ref. 8900-0800-01 is the recommended replacement: it is the original electrode with Real CPR Help.
- If your public access defibrillation programme does not require a CPR sensor, the Stat-Padz II (8900-0801), with a lower cost per pair, or the multipack of 12 pairs (8900-0802-01) for fleets, may be considered.
- For paediatric patients (under 8 years / under 25 kg), always use the Pedi-Padz II (8900-0810-01): AED Plus/AED Pro automatically switch to paediatric energy levels when this electrode is detected.
- On ZOLL AED 3 devices, the correct replacement is the CPR Uni-padz universal (8900-000260), not this electrode, due to the connector difference.
- Manage stock rotation by expiry: the 5-year service life reduces the total cost of ownership, but the date printed on the packaging must be checked.
- Consult the Cahnos technical department to confirm exact compatibility with your defibrillator model before placing large-volume orders or tenders.