Training electrodes ZOLL Stat•padz II for simulator AED Plus TRAINER 2 (Ref. 8900-0805-01) – Box of 6 pairs

269,00 €

Original replacement for training electrodes ZOLL Stat•padz II (ref. 8900-0805-01) for the simulator ZOLL AED Plus TRAINER 2. They faithfully reproduce the placement and handling of the clinical pads so that students can practise the complete defibrillation sequence on a manikin, without releasing any discharge energy. Supplied in a box of 6 pairs; proprietary pre-connected connector for Trainer. Exclusively for training and simulation: not suitable for clinical use or on patients.

International shipping. Import duties and taxes are payable by the recipient.

Reference
8900‐0805‐01

Description

1. Introduction

The ZOLL Stat•padz II training electrodes (ref. 8900-0805-01) are the official practice consumable for the ZOLL AED Plus TRAINER 2 simulator. They are designed to allow life support academies, emergency services, hospital training departments and CPR training centres to practise defibrillator handling in a realistic, safe and repeatable manner. Each session faithfully reproduces the appearance and placement of the clinical Stat•padz II electrodes without delivering a discharge, ensuring 100% safe practice on a manikin and consistent performance in every rescue scenario.

2. Technical explanation of the equipment and procedure

The ZOLL AED Plus TRAINER 2 simulator (equipment ref. 8008-0050-10) replicates the voice prompts, rescue scenarios and operating sequence of the real AED, allowing the instructor to assess the student’s response without risk. The Stat•padz II training electrodes reproduce the clinical two-piece configuration (sternum/apex position on the manikin’s chest) and connect to the simulator via the preconnected proprietary ZOLL connector, reducing class preparation time. Their adhesive is formulated to withstand multiple applications in successive sessions, optimising the cost per student in continuing education programmes. These pads are teaching consumables: they do not perform analysis or deliver a shock and must only be used with Trainer family equipment.

3. Technical Specifications

Manufacturer ZOLL Medical Corporation
Official manufacturer reference 8900-0805-01 (Stat•padz II Training Electrodes, 6 pairs per case)
Model Stat•padz II (training and simulation version)
Product type Training electrodes / pads (non-clinical)
Compatibility Simulator ZOLL AED Plus Trainer (previous model) and Trainer 2 (simulator ref. 8008-0050-10 / 8008-0050-01)
Presentation Case of 6 pairs of electrodes
Sales unit Electrode pairs
Design Two pieces that reproduce the geometry of the clinical Stat•padz II
Adhesive gel Low-tack training adhesive, reusable over multiple applications
Connection Preconnected, proprietary ZOLL connector for Trainer
Electric discharge Does not release energy (simulation only)
Use Medical training and simulation – not suitable for clinical use or patients

Always check the expiry date printed on the packaging and replace the electrodes when the gel shows wear or loss of adhesion.

4. Equivalences and Cross-References

Reference 8900-0805-01 is confirmed in the official ZOLL store (ZOLL Webstore) and at authorised distributors such as ZOL-8900-0805-01; both forms correspond to the same factory reference. There is no ZOLL-validated equivalence table that would allow these training electrodes to be replaced by consumables from other manufacturers (e.g. Philips HeartStart or Stryker/Physio-Control LIFEPAK): the connector, geometry and simulator algorithm are proprietary to ZOLL, so any comparison with other systems should be understood as comparable at category level, not interchangeable 1:1, and must be confirmed with the technical department before use in tenders.

Reference Product Related items
8900-0805-01 Stat•padz II training electrodes for Trainer 2 (case of 6 pairs) Reference covered by this datasheet
8900-000861-01 / 8900-00861-01 Pedi•padz II training electrodes for Trainer / Trainer 2 (case of 6 pairs) Complementary: paediatric practice
8900-0804-01 CPR-D•padz training for Trainer 2 (reusable Z-design electrode with CPR indicator + gels) Complementary: practice with compression guidance
8008-0050-10 ZOLL AED PLUS TRAINER 2 (complete simulator) Compatible equipment
8008-0007 Wireless remote control for Trainer 2 Complementary for the instructor
8000-0375-01 ZOLL Trainer 2 carry bag Complementary, protection and transport
8900-0801 / 8900-0801-01 Clinical adult Stat•padz II (1 pair) for AED Plus / AED Pro Clinical functional equivalent – NOT suitable for training or vice versa
8900-0802-01 Clinical adult Stat•padz II (case of 12 pairs) Clinical, multipack format

5. Selection tips and variants of interest

Confirm your simulator model: these electrodes are valid for the ZOLL AED Plus Trainer and Trainer 2; check your equipment reference (8008-0050-10 / 8008-0050-01). For adult scenarios, this case of 6 pairs is the recommended supply; for paediatric practice use the Pedi•padz II training electrodes (8900-000861-01) and for compression-guided training, the CPR-D•padz training electrodes (8900-0804-01). Never mix clinical and training use: training electrodes must not be connected to clinical defibrillators or used on patients, and clinical electrodes must not be used with the Trainer. Manage stock rotation by packaging expiry date and always keep a spare set so that course scheduling is not interrupted. Complete your simulation classroom with the remote control (8008-0007) and the carry bag (8000-0375-01) for a comprehensive training programme. Consult the Cahnos technical department to confirm exact compatibility with your equipment before large-volume orders or tenders.

Additional information

Manufacturer

ZOLL Medical Corporation

Manufacturer reference

8900-0805-01

Model

Stat•padz II (training version)

Product type

Training electrodes (non-clinical)

Presentation

Case of 6 pairs

Compatibility

Simulator ZOLL AED Plus Trainer and Trainer 2 (ref. 8008-0050-10)

Adhesive gel

Reusable low-tack adhesive

Connection

Preconnected, proprietary ZOLL connector

Electric discharge

Does not release energy (simulation only)

Use

Exclusively for training and simulation