Description
1. Commercial Introduction
The PRIMEDIC HeartSave AED-M (Ref. 33399 / SKU Cahnos GM33399) is a semi-automatic external defibrillator with ECG recording and integrated monitor, designed to provide rapid, safe and effective resuscitation in heart-safe spaces, emergency services, ambulances, healthcare facilities, sports venues and businesses. It is part of the renowned HeartSave family from the German group Metrax-Primedic, a defibrillation platform with proven clinical reliability, distributed in Spain.
The device combines extremely simple operation with professional-level features: automatic analysis of the heart rhythm, detection of shockable rhythms (VF/VT), clear voice instructions that guide the rescuer, and visual monitoring of the ECG waveform on a large LCD screen. Its non-rechargeable lithium battery with a 6-year standby life simplifies maintenance and ensures the device is always ready to act. Class II B medical device: consult your Cahnos technical-commercial advisor for supply conditions. For large orders you can request a quote.
2. Technical explanation of the equipment
The HeartSave AED-M is a semi-automatic defibrillator: after placing the pre-connected electrodes, the device automatically analyses the heart rhythm and, if it detects a shockable rhythm, tells the rescuer when to deliver the shock. This configuration allows use by non-medical personnel trained in basic life support, while maintaining the monitoring and recording functions typical of a professional device.
The shock waveform uses CCD (controlled current defibrillation) technology: a current-controlled biphasic impulse, free of peaks, delivered individually, gently and effectively to the patient’s cardiac muscle, with impedance compensation and a stepped energy strategy up to a maximum of 360 J. The advanced workflow helps the rescuer minimise the pre-shock pause and the no-flow fraction, maximising the effectiveness of cardiopulmonary resuscitation.
The device incorporates a selectable paediatric mode with a single press, without the need for dedicated paediatric electrodes, and it switches on automatically when the lid is opened: rhythm analysis begins as soon as the pre-connected electrodes are attached to the patient. The lid includes all necessary accessories (blade, ventilation face mask, scissors and gloves). The status display provides complete information on the operational status of the defibrillator and battery, including daily and monthly self-tests.
3. Technical Specifications
3.1. Defibrillation and rhythm analysis
| Parameter | Specification |
|---|---|
| Operating mode | Semi-automatic (AED with ECG and monitor) |
| Waveform | Biphasic, current-controlled impulse (CCD) |
| Energy | 50–360 J |
| Weight-bearing time | < 12 s at 360 J |
| Operating modes | Asynchronous; paediatric mode |
| VF/VT detection | Yes (automatic rhythm analysis) |
| Analysis time | 7–12 s |
| Asystole threshold | < 0.2 mV |
| Artefact and pacemaker detection | Yes |
3.2. ECG monitoring
| Parameter | Specification |
|---|---|
| Lead | II |
| Patient impedance range | 23–200 ohm |
| Heart rate | 30–300 per min |
3.3. Display (LCD monitor)
| Parameter | Specification |
|---|---|
| Screen size | 95 x 72 mm (diagonal 4.7″ / 120 mm) |
| Resolution | 320 x 240 pixels (pixel size 0.36 x 0.36 mm) |
| Speed | 25 mm/s |
| Information displayed | ECG waveform, heart rate, number of defibrillations, number of VF/VT and total resuscitation time |
| Battery status display | Yes |
3.4. Electrodes and data recording
| Parameter | Specification |
|---|---|
| Electrodes | Non-polarised, cable length 2 m |
| Data backup | Removable memory with voice recording |
| Standard equipment | SavePads, data and voice recording, manual |
3.5. Power supply and maintenance
| Parameter | Specification |
|---|---|
| Battery | Non-rechargeable lithium, 6 years standby life or 200 shocks at 200 J, and 15 hours of monitoring |
| Self-tests | Daily and monthly (defibrillator and battery status) |
3.6. Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | Z12030501 |
| GMDN | 37806 |
| EAN | 8023279333992 |
Note: this “other languages” version allows the device to be supplied with voice and manual in the following languages: BG, CZ, DK, FI, HR, HU, MK, NL, NO, RO, RU, SE, SI, TR, AE, CN, IR and TH. The language must be specified when placing the order. Available within 40/60 days.
4. Equivalences and Cross-References
This reference (Ref. 33399, SKU Cahnos GM33399) belongs to the HeartSave AED and AED-M defibrillator family of the Metrax-Primedic platform, together with references 33384, 33385, 33391, 33392, 33394, 33396 and 33397, with which it shares consumables, battery and accessories. Within the Cahnos catalogue, the platform is covered by the following verified spare parts and accessories:
| Manufacturer / Brand | Product | Reference | Related items |
|---|---|---|---|
| . | Non-rechargeable lithium battery, 6 years, for HeartSave AED / AED-M | 33387 (SKU GM33387) | Replacement battery for this reference |
| . | Rechargeable AkuPak Lite battery (PowerPak system) | 33400 (SKU GM33400) | Rechargeable alternative for the platform |
| Metrax-Primedic | SavePads-SET adult (>8 years) for HeartSave up to S.N. 738XXXXXXX | 33388 (SKU GM33388) | Compatible original electrodes |
| Metrax-Primedic | SavePads PreConnect-Set adult/child from S.N. 739XXXXXXX | 35392 (SKU GM35392) | New-generation pre-connected electrodes |
| Metrax-Primedic | SavePads Mini paediatric 1–8 years | 35390 (SKU GM35390) | Compatible paediatric electrodes |
| Cahnos (compatible) | Adult electrodes compatible with external cable | F7960W | Compatible consumable |
| Cahnos (compatible) | Adult radiolucent electrodes with external cable | F7760W | Compatible consumable |
There is no equivalence table validated by the manufacturer that would allow this defibrillator to be replaced by equipment from other brands (e.g. Philips HeartStart, ZOLL, Stryker LIFEPAK or Bexen): each defibrillation platform uses proprietary connectors, analysis algorithms and energy management, so they are not interchangeable 1:1. Always verify the model, serial number and connector type of your equipment before purchasing spare parts, and consult the technical department of Cahnos before any cross-reference in tenders.
5. Selection tips and variants of interest
Identify your language version: this reference corresponds to the “other languages” version of the HeartSave AED-M. Indicate the desired language (voice + manual) when placing the order; supply of these variants requires a lead time of 40/60 days. If your service operates in Spanish as the standard language, consider the conventional versions of the HeartSave AED-M family (refs. 33384/33385, 33391/33392, 33394/33396/33397), also available in the manufacturer’s catalogue.
Manage the energy spare part: the device operates with a long-life non-rechargeable lithium battery (6 years standby, ref. 33387). Plan preventive replacement according to the manufacturing date indicated on the label, without waiting for the low battery warning. If your fleet works with a recharging protocol, the AkuPak Lite battery (ref. 33400) with its PowerPak charger (ref. 33407) is the rechargeable alternative on the same platform.
Maintain the consumables supply: always keep a set of in-date SavePads electrodes (refs. 33388, 35392 or the compatible F7960W/F7760W) and, if you attend to paediatric patients, the SavePads Mini (ref. 35390). Respect the expiry date of the pads and rotate stock using the FIFO method. Periodically check the device’s self-tests and the battery display status.
Intended use: semi-automatic defibrillation and ECG monitoring in the field of life support and cardiac protection. Contact the technical-commercial department of Cahnos indicating the configuration, language and units required to formalise your quotation.





Reviews
There are no reviews yet.