Description
1. Commercial Introduction
Keep your Marquette GE or Esaote defibrillator-monitor always ready to attend to even the smallest patients. This pair of standard paediatric defibrillator electrodes with internal cable (reference Cahnos F7962P) is the replacement consumable indicated for paediatric defibrillation: a single pair of disposable pads ensures a secure connection with the equipment at the critical moment of cardiorespiratory arrest.
It is the ideal solution for emergency departments, paediatric intensive care units (PICU), ambulances, health centres and heart-safe spaces with a flow of children, available with immediate dispatch from Cahnos and specialised technical support to verify compatibility by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and, in most models, allows emergency electrocardiogram monitoring. In paediatric patients (under 8 years of age or weighing less than 25 kg) it is essential to attenuate the energy to avoid myocardial injury; therefore this electrode incorporates a reduced active surface of 40 cm² per pad and must be used with the equipment’s paediatric mode switching or with the reduced energy configuration (50–100 J) indicated in the defibrillator manual.
The configuration with integrated internal cable connects the pad directly to the equipment’s electrode socket, without loose cables during resuscitation. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and medical foam (FOAM) of 1 mm thickness guarantee a uniform distribution of current over the child’s chest. The recommended placement is anterolateral (sternum-apex position), without both pads coming into contact with each other. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7962P |
| Product type | Standard paediatric defibrillator electrode pair, multifunction, with internal cable |
| Compatible brands | Marquette GE and Esaote |
| Compatible models | Marquette 1250 First Responder, 1500 First Responder, Responder 2000 (documented family: Responder 3000); Esaote MDF and MDF Plus (verify connector) |
| Indicated population | Paediatric (< 8 years / < 25 kg) |
| Cable configuration | Integrated internal cable (direct connection to the equipment electrode socket) |
| Adhesive ring width | 1 cm |
| Total surface (per electrode) | 75 cm² |
| Active surface (per electrode) | 40 cm² |
| Supported shocks | Up to 50 shocks (paediatric energy 50–100 J) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector / clip (depending on model), with internal cable |
| ECG monitoring | Up to 24 h |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Presentation | Price per pair (2 units); 1 pair in heat-sealed polyethylene and aluminium bag; 5 pairs per box (paediatric series) |
| Operating temperature | Between 0 °C and +50 °C |
| Storage | Dry place, between +5 °C and +35 °C |
| Shelf life | 30 months from date of manufacture; expiry date indicated on the packaging |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
Note: the values for active surface (40 cm²), total area (75 cm²), discharges (50–100 J) and adhesive ring (1 cm) correspond to the standard paediatric electrode series with internal cable of this product family; confirm them with the technical data sheet of the supplied batch and with the equipment manual before use in tendering.
3.1 Compatibility with defibrillators
| Equipment brand | Compatible models | Cable / connection |
|---|---|---|
| Marquette GE | 1250 First Responder, 1500 First Responder, Responder 2000 (documented family: Responder 3000) | Equipment internal cable (in the family, the GE Medical Systems cable ref. 22338301 is documented; verify connector fit) |
| Esaote | MDF, MDF Plus (documented family) | Equipment internal cable; confirm the exact model and connector before replacement |
Always verify the correct fit of the connector in the equipment’s electrode socket before clinical use.
4. Equivalences and Cross-References
The reference F7962P is the Cahnos distribution code for this paediatric electrode compatible with Marquette GE and Esaote; it is not an official reference of the equipment manufacturer. The connector and energy management of each defibrillator are proprietary, so equivalences with other brands are comparable only at category level and not interchangeable 1:1. The following cross-references have a confirmed code in public sources (official manufacturer website and/or GUDID regulatory database):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| ZOLL Medical | Pedi-padz® II (original multifunction paediatric electrodes) | 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Factory original pre-connected for AED Plus and AED Pro; solid low-impedance gel and paediatric levels of 50/70/85 J automatically selected by the equipment. Code confirmed on the manufacturer’s website and GUDID (UDI 00847946001438). Not suitable for Marquette GE/Esaote equipment due to proprietary connector. |
| Philips | Infant/Child Reduced-Energy Defibrillator Pads (for HeartStart FR2 / FR2+) | M3870A (also 989803108851) | Comparable by category (not interchangeable 1:1) | Paediatric pad that reduces energy (150 J → 50 J) with proprietary connector and algorithm Philips; not compatible with the socket of GE/Esaote equipment. Code verified in GUDID (UDI-DI 00884838023734) and on the official Philips website. |
| Schiller | Paediatric electrodes FRED PA-1 / FRED EasyPort (child pads) | 2.155067 / 2.155062 | Comparable by category (not interchangeable 1:1) | Factory original replacement pre-connected for the FRED/Argus/Defigard family; same paediatric criteria (< 8 years / < 25 kg) but connector and algorithm specific to Schiller. Codes consistently cited in authorised distributors of original spare parts. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
- Confirm the model and connector of the equipment: verify that your defibrillator is a Marquette GE (1250 or 1500 First Responder, Responder 2000/3000) or an Esaote (MDF, MDF Plus) and that the internal cable connector fits correctly into the electrode socket before clinical use. In case of doubt, contact the Cahnos technical department indicating the model and serial number.
- Do not confuse the paediatric and adult versions: this pair is for patients under 8 years of age or weighing less than 25 kg. For adult patients of the same connector family, the standard adult version with internal cable is available.
- Paediatric mode: always select the paediatric energy configuration (50–100 J) indicated in the equipment manual; do not manually modify energy levels without protocol indication.
- Variants of the same Cahnos family: for mixed fleets you will find reference F7972P (same Marquette GE/Esaote family with Snap connection on GE cable 22338301), F7981P (GE type Responder/CardioServ) or F7952P (multi-brand standard paediatric series). Always verify which connector family corresponds to each equipment.
- Storage and expiry: check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity. As it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date.






Reviews