Ensure safe and effective cardiac care for the smallest patients with this pair of standard paediatric defibrillator electrodes (reference Cahnos F7952P), a high-reliability consumable compatible with Physio-Control LIFEPAK defibrillators and monitors and with Bexen Cardio, Cardioline and Mindray equipment. Designed for emergency departments, paediatric intensive care units, consulting rooms, medical transport and cardioprotected spaces with children, it combines the robustness of the standard series with the operability of the integrated internal cable: the connector remains fixed to the device, with no loose cables, and the set is ready for immediate connection during paediatric cardiorespiratory arrest. A cost-optimised solution, compliant with European medical device standards (class IIb) and latex- and phthalate-free.
2. Technical explanation of the equipment and procedure
Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the rhythm, delivers therapy and monitors the electrocardiographic response. This paediatric model allows transthoracic external defibrillation, synchronised cardioversion and ECG monitoring (up to 24 h), adapted to paediatric physiology (children under 8 years of age or weighing less than 25 kg). It is not indicated for transcutaneous cardiac pacing (pacemaker): use it only for the stated functions.
In paediatric patients it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode incorporates a reduced active surface of 40 cm² per electrode and must be used with the device’s paediatric mode switch or with the reduced energy setting (50–100 J) indicated in the defibrillator manual. The internal cable configuration connects the pad directly to the device’s electrode socket, with no loose cables during resuscitation. The low-impedance conductive adhesive gel on 1 mm medical foam with a conductive metal foil ensures stable adhesion, uniform current distribution and a reliable signal. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging, placed according to the anatomical diagrams (sternal and apical position) on the sachet.
3. Technical Specifications
Standard paediatric multifunction electrode from the EuroDefiPads paediatric series, in its 100 cm internal cable variant.
| Field | Specification |
| Reference Cahnos (SKU) | F7952P |
| Product type | Paediatric multifunction defibrillator electrode pair, standard, with internal cable |
| Indicated population | Children under 8 years or weighing less than 25 kg |
| Cable | 100 cm, internal (integrated) |
| Radiotransparency | No (standard version) |
| Functions | Defibrillation, synchronised cardioversion and ECG monitoring (max. 24 h). Not suitable for pacing (pace) |
| Supported shocks | Up to 50 shocks at 100 J (paediatric series) |
| Total area (per electrode) | 75 cm² |
| Active area (per electrode) | 40 cm² |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | 1 mm thick medical foam |
| Connection type | Safety shockproof connector / QUIK-COMBO clip type (depending on equipment model) |
| Presentation | 1 pair (2 electrodes); 5 pairs per box (paediatric series) |
| Use | Single-use, disposable; latex-free and phthalate-free |
| Shelf life | Approx. 30 months from date of manufacture (expiry printed on packaging) |
| Conditions of use and storage | Operating temperature from 0 °C to +50 °C; store in a dry place between +5 °C and +35 °C |
| Classification | Medical device class IIb (Directive 93/42/EEC and amendments; EU Regulation 2017/745) |
| Regulatory standard | ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10 |
3.1 Compatibility with defibrillators
| Equipment manufacturer | Compatible models |
| Physio-Control / Medtronic | LIFEPAK 9 (with QUIK-COMBO adapter), LIFEPAK 10, LIFEPAK 12, LIFEPAK 15, LIFEPAK 20 |
| Mindray | BeneHeart D1, BeneHeart D3, BeneHeart D6 |
| Bexen Cardio | REANIBEX-200, REANIBEX-300, REANIBEX-500, REANIBEX-700, REANIBEX-800 |
| Cardioline | ELIFE 700 |
Note: the same product family also documents compatibility with other equipment in the range (e.g. Comen S8) according to the manufacturer’s technical data sheet. Always verify the correct insertion of the connector into the device socket before clinical use.
4. Equivalences and Cross-References
This electrode (SKU F7952P) is a consumable compatible with the cited equipment, not an original factory spare part. The correspondence with the equipment manufacturers’ references is as follows; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Stryker / Physio-Control | Paediatric EDGE System radiotransparent electrodes with QUIK-COMBO connector (original equipment) | 11996-000090 | Comparable by category (not interchangeable 1:1) | Factory original for LIFEPAK 12, 15 and 20 defibrillators and monitors; QUIK-COMBO connector, paediatric multifunction (defibrillation, pacing and ECG), paediatric use 0–15 kg. It differs from this reference in its radiotransparent (RTS) construction and in that it does allow pacing; this data sheet is the standard non-radiotransparent variant and not suitable for pacing. Code confirmed in the official Stryker store, authorised distributors and GUDID (UDI 00721902195037). Not suitable for equipment of other brands. |
| Mindray | MR61 – Paediatric multifunction electrode (original spare part for BeneHeart series) | 115-040518-00 | Comparable by category (not interchangeable 1:1) | Mindray original for BeneHeart D1, D2, D3, D5, D6 and C series defibrillators; paediatric population under 25 kg; Mindray proprietary connector and algorithm, not compatible with the QUIK-COMBO socket of LIFEPAK devices. Code confirmed in the official Mindray pad guide and in manufacturer reference sources. |
For Bexen Cardio REANIBEX and Cardioline ELIFE 700 equipment, no verifiable original paediatric electrode code has been found in public sources; confirmation with the manufacturer is pending. There is no equivalence table validated by Physio-Control/Stryker, Mindray or Bexen Cardio that authorises the replacement of original references 11996-000090 or 115-040518-00 with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any replacement must be validated against the defibrillator’s technical data sheet and IFU. Consult Cahnos’s technical department before use in tenders.
5. Selection tips and variants of interest
Confirm the model and connector of the device: this pair corresponds to Physio-Control LIFEPAK 9 (with QUIK-COMBO adapter), 10, 12, 15 and 20 defibrillators and monitors, and to Mindray BeneHeart, Bexen Cardio REANIBEX and Cardioline ELIFE 700 equipment. Verify the reference and expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after an intervention: the gel may lose conductivity and compromise the effectiveness of the shock.
Choose the variant according to your workflow: the internal cable of this model (F7952P) provides a clean and robust connection during resuscitation; if you prefer to leave the equipment preconnected and ready in seconds, the reference F7952PW is available (same standard paediatric series with external lead-out cable). For an artefact-free imaging requirement (X-ray or CT during assistance), consider the radiolucent series F7752P (internal cable) or F7752PW (external cable). For AED equipment with automatic energy reduction, the references F7952PL and F7952WPL (200 J → 50 J) are the indicated ones.
Maintenance and supply: manage stock rotation by expiry date (approx. 30 months) and always keep a spare pair next to the equipment in centres with a paediatric population. For volume orders or tenders, contact the technical department of Cahnos indicating the exact model and the serial number of the defibrillator.