Keep your GE defibrillator always ready to treat the smallest patients as well. This pair of standard paediatric defibrillator electrodes with internal cable (reference Cahnos F7981P) is the recommended replacement consumable for paediatric defibrillation with GE Responder 3000, Responder 2000, Responder 1100, Cardioserv and Dash Responder equipment with direct connection. It is supplied as a pair (2 units) in an individual heat-sealed package, ready to be integrated into resuscitation protocols in emergency departments, paediatric intensive care units, ambulances, health centres and cardioprotected areas with children present. A reliable, single-use solution for cardiorespiratory arrest in paediatrics, with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock, enables non-invasive pacing (if supported by the device) and monitors the emergency electrocardiogram. In paediatric patients under 8 years of age or weighing less than 25 kg, it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode has a reduced active surface area (40 cm² per electrode) and must be used with the device’s paediatric mode switching or with the reduced energy configuration indicated in the defibrillator manual.
The integrated internal cable configuration provides a stable, direct connection to the device’s electrode socket, with no loose cables during resuscitation. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and medical foam (FOAM) 1 mm thick guarantee uniform current distribution over the child’s chest. The recommended placement is anterolateral (sternum-apex position), maintaining a minimum separation between the two pads. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
3.1 Product identification
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7981P |
| Original GE factory code (device direct-wired paediatric electrode) | 2059144-001 / 2059144-005 (Leonhard Lang / Skintact factory codes: DF69, 50461) |
| Product type | Standard multifunction paediatric electrode pair with internal cable |
| Brand / compatible equipment | GE (General Electric) – Responder 3000, Responder 2000, Responder 1100, Cardioserv and Dash Responder (direct connection) |
| Presentation | Price per pair (2 units); individual heat-sealed package; 5 pairs per box (paediatric series) |
3.2 Technical specifications
| Parameter | Specification |
|---|---|
| Target population | Paediatric (< 8 years / < 25 kg) |
| Cable configuration | Integrated internal cable (direct connection to the equipment electrode socket) |
| Total surface (per electrode) | 75 cm² |
| Active surface (per electrode) | 40 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50–100 J in paediatric configuration) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector with internal cable |
| ECG monitoring | Up to 24 h |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Shelf life | Approx. 30 months from the date of production; expiry indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C |
The active surface area, total area, shock and adhesive ring values correspond to the standard paediatric electrode series with internal cable in this product family; confirm them with the technical data sheet of the supplied batch and the device manual before use in tendering.
3.3 Compatibility with defibrillators
| Equipment brand | Compatible models | Connection |
|---|---|---|
| GE | Responder 3000 | Direct connection |
| GE | Responder 2000 | Direct connection |
| GE | Responder 1100 | Direct connection |
| GE | Cardioserv | Direct connection |
| GE | Dash Responder | Direct connection |
Technical note: always verify the correct insertion of the connector into the device socket before clinical use.
4. Equivalences and Cross-References
This electrode (SKU F7981P) belongs to the standard paediatric consumables family with internal cable for defibrillation. Reference F7981P is Cahnos’s own distribution code; the official GE Healthcare reference for the original paediatric electrode with direct connection for this equipment family is 2059144-001 / 2059144-005 (manufactured for GE by Leonhard Lang / Skintact, with internal codes DF69 and 50461), verified in regulatory records (TGA notice / GUDID database) and in original spare parts distribution sources. It should not be confused with reference 2059145 (original GE adult electrode of the same connection system). Equivalences with other brands are comparable only at category level: the connector, analysis algorithm and energy management are proprietary to each device, so they are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| GE Healthcare (original replacement) | Disposable direct-wired paediatric defibrillation/pacing electrode for Responder 1100/2000/3000, Cardioserv and Dash Responder (OEM Leonhard Lang / Skintact) | 2059144-001 / 2059144-005 (factory codes DF69, 50461) | Comparable by category (not interchangeable 1:1) | Original factory replacement with the same compatibility declared in this data sheet; verified in TGA/MDD regulatory notice and original GE spare parts source (mercateo). It is cited as a contrast reference for the compatible Cahnos F7981P pad. Do not confuse with the adult electrode 2059145. |
| Leonhard Lang | Skintact® Easibeat paediatric multifunction (< 25 kg) – Philips HeartStart connector | DF32G | Comparable by category (not interchangeable 1:1) | Paediatric multifunction electrode for defibrillation, pacing and monitoring with Philips HeartStart connector (FR2, FR2+, FR3 or with M3508A / M3507A adapter cables for MRx, XL, XL+, Efficia DFM100); 2.0 m cable. Code confirmed in the official Leonhard Lang catalogue. Not suitable for GE equipment. |
| Leonhard Lang | Skintact® Easibeat paediatric multifunction (< 25 kg) – ZOLL connector | DF30G | Comparable by category (not interchangeable 1:1) | Multifunction paediatric electrode with ZOLL connector for E-Series, M-Series and R-Series; 1.2 m cable. Code confirmed in the official Leonhard Lang catalogue and with authorised distributors. Not suitable for GE equipment. |
| ZOLL Medical | Pedi·Padz II – multifunction paediatric electrodes (original equipment) | 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Factory original with conductive hydrogel and paediatric energy levels of 50/70/85 J for AED Plus, AED Pro and manual use in M/E/R Series. Code confirmed on the manufacturer’s website and GUDID (UDI 00847946001438). Not suitable for GE equipment. |
There is no equivalence table validated by GE Healthcare that authorises the replacement of the original electrodes with third-party pads: the connector, the analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the Cahnos technical department before use in tenders. Within the Cahnos catalogue there are other references in the same family (standard paediatric with internal cable) intended for equipment from other manufacturers, not interchangeable with each other: F7985P (Instramed CardioMax), F7951P (ZOLL), F7961P (Nihon Kohden) and F7986P (Mediana D500). The adult version of the same GE connection system is the F7981 (internal cable).
5. Selection tips and variants of interest
- Confirm the equipment model: verify that your defibrillator is a GE Responder 3000, Responder 2000, Responder 1100, Cardioserv or Dash Responder and that the internal cable connector fits correctly into the electrode socket of the equipment before clinical use; if in doubt, contact the Cahnos technical department stating the model and serial number.
- Do not confuse the paediatric and adult versions: this pair is for patients under 8 years of age or weighing less than 25 kg; for adult patients use reference F7981 (standard adult with GE internal cable, same connector family).
- Energy in paediatric mode: always select the paediatric or reduced energy configuration indicated in the equipment manual; do not manually modify energy levels without protocol indication.
- Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity.
- Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of your equipment.