We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Standard paediatric defibrillator electrode with pre-connected external cable — Replacement compatible with ZOLL PD 1200 to PD 2000, E Series and M Series — Ref. F7951PW

39,75 €

Pair of standard paediatric defibrillator electrodes with pre-connected external cable (Ref. F7951PW), replacement compatible with the ZOLL Medical PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series and M Series defibrillators and monitors. Indicated for patients under 8 years of age or weighing less than 25 kg, it is multifunctional: defibrillation, synchronised cardioversion and ECG monitoring (up to 24 h). Its reduced active surface area of 40 cm² per electrode concentrates the energy on the paediatric chest, and the external cable (100 cm) allows the device to be kept always ready to act in emergencies. Low-impedance conductive adhesive gel, safety anti-shock connector, single-use, latex-free and phthalate-free. Sold as a pair; 5 pairs per box.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7951PW

Description

1. Commercial Introduction

Ensure safe and effective cardiopulmonary resuscitation in the smallest patients with this pair of standard paediatric defibrillator electrodes with external cable (reference Cahnos F7951PW), a high-reliability consumable compatible with the ZOLL Medical defibrillators and monitors of the PD, E and M series. Designed for emergency departments, paediatric intensive care, medical transport and settings with professional-use AEDs, it combines the robustness of the standard series with the operability of the pre-connected external cable: the connector is always accessible and the device ready for immediate connection, a decisive advantage in paediatric cardiorespiratory arrest. A cost-optimised solution, compliant with European medical device standards (class IIb) and latex-free and phthalate-free.

2. Technical explanation of the equipment and procedure

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the rhythm, delivers therapy and monitors the response. This paediatric model is indicated for external transthoracic defibrillation, synchronised cardioversion and ECG monitoring (up to 24 h), adapted to paediatric physiology (children under 8 years or weighing less than 25 kg).

In paediatric patients it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode incorporates a reduced active surface of 40 cm² per electrode and must be used with the device’s paediatric mode switching or with the reduced energy setting (50–100 J) indicated in the defibrillator manual. The external cable variant allows the connector to be left accessible and the pad ready, reducing preparation time in emergencies. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and 1 mm medical foam guarantee a uniform distribution of current. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging, placed according to the anatomical diagrams (sternal and apical position) on the pouch.

3. Technical Specifications

Standard paediatric multifunction electrode from the paediatric defibrillator pad series, in its 100 cm external cable (pre-connected) variant.

Field Specification
Reference Cahnos (SKU) F7951PW
Product type Standard paediatric multifunction defibrillator electrode pair with external cable (pre-connected)
Indicated population Children under 8 years or weighing less than 25 kg
Cable External (pre-connected), 100 cm
Functions Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h)
Supported shocks 50 to 100 J (paediatric series)
Total surface (per electrode) 75 cm²
Active area (per electrode) 40 cm²
Adhesive ring width 0.7 cm
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (1 mm thick)
Connection type Safety anti-shock connector
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 5 pairs per box (paediatric series)
Use Single-use, disposable; latex-free and phthalate-free
Shelf life Approx. 30 months from date of manufacture (check printed expiry date)
Conditions of use and storage Operating temperature from 0 °C to +50 °C; store in a dry place between +5 °C and +35 °C
Classification Class IIb medical device (Directive 93/42/EEC and amendments; EU Regulation 2017/745)
Regulatory standard ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10

Compatibility (equipment models)

Equipment manufacturer Compatible models
ZOLL Medical PD 1200, PD 1400, PD 1600, PD 1700, PD 2000
ZOLL Medical E Series, M Series

Technical note: always verify the correct insertion of the connector into the device socket before clinical use.

4. Equivalences and Cross-References

This electrode (SKU F7951PW) is a consumable compatible with the cited ZOLL equipment, not an original factory spare part. The correspondence with the equipment manufacturers’ references is as follows; any comparison between brands must be understood as comparable at category level, not 1:1 interchangeable.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
ZOLL Medical Pedi·Padz II — multifunction paediatric electrodes (original equipment) 8900-0810-01 Comparable by category (not interchangeable 1:1) Factory original with intelligent paediatric capability for AED Plus and AED Pro; in M/E/R Series it is used in manual mode. Hydrogel with tin conductive element, pre-connected, paediatric range 0–8 years / less than 25 kg with levels of 50/70/85 J. Code confirmed in the official ZOLL store and in GUDID (UDI 00847946001438).
Stryker / Physio-Control Infant/Child Reduced Energy Defibrillation Electrodes (for LIFEPAK with pink connector) 11101-000016 Comparable by category (not interchangeable 1:1) Paediatric electrode with energy reduction (200 J → ≈50 J) for the LIFEPAK 500, 1000, EXPRESS and CR Plus AEDs; proprietary QUIK-COMBO connector and algorithm, not suitable for ZOLL equipment. Code confirmed in the official Stryker store and in GUDID (UDI 00721902629013).
Defibtech Lifeline AED Child / Pediatric Electrode Pads DDP-200P Comparable by category (not interchangeable 1:1) Paediatric electrodes with integrated energy attenuation for children under 8 years or less than 25 kg; proprietary connector, algorithm and electronics of Lifeline equipment. GUDID/FDA UDI-DI registration 00815098020430.

There is no equivalence table validated by ZOLL Medical that authorises the replacement of the original Pedi·Padz electrodes with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator. Consult the technical department of Cahnos before use in tenders.

5. Selection tips and variants of interest

Confirm the model and connector of the device: this pair corresponds to the ZOLL defibrillators and monitors PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series and M Series. Verify the reference and expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after an intervention.

Choose the variant according to your workflow: the external cable of this model allows the device to be left pre-connected and ready in seconds; if you prefer an internal cable, the F7951P reference is available (same standard paediatric series). For artefact-free imaging requirements, consider the radiotranslucent series F7751P (internal cable) or F7751PW (external cable), with the same ZOLL compatibility. The adult version of this same family is the F7951W.

Maintenance and provisioning: manage stock rotation by expiry date (approx. 30 months from manufacture) and always keep a spare pair next to the device in centres with a paediatric population. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of the defibrillator.

Additional information

Reference

F7951PW

Product type

Standard paediatric multifunction defibrillator electrode pair with external cable (pre-connected)

Patient type

Paediatric (

Compatibility

PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series

Cable

External (pre-connected), 100 cm

Functions

Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h)

Supported shocks

50 to 100 J

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Adhesive ring width

0.7 cm

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

Medical foam (1 mm thick)

Connection type

Safety anti-shock connector

Use

Single-use, disposable; latex-free and phthalate-free

Presentation

1 pair in heat-sealed bag; 5 pairs per box (paediatric series)

Shelf life

Approx. 30 months from date of manufacture

Storage

Dry place between +5 °C and +35 °C; operating range 0 °C to +50 °C

Classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10

Reviews

There are no reviews yet.

Be the first to review “Standard paediatric defibrillator electrode with pre-connected external cable — Replacement compatible with ZOLL PD 1200 to PD 2000, E Series and M Series — Ref. F7951PW”

Your email address will not be published. Required fields are marked *