Pair of standard paediatric defibrillator electrodes with external cable (100 cm) – Compatible replacement for Philips, Agilent Hewlett-Packard and Laerdal Medical: CodeMaster 100, XE, XL, XL+ and HeartStart 4000 – Ref. F7953PW

39,75 €

Pair of standard paediatric defibrillator electrodes with external cable (Ref. F7953PW), a replacement compatible with the Philips, Agilent Hewlett-Packard and Laerdal Medical defibrillator-monitors: CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), HeartStream XL/XLT and MRx. Indicated for children under 8 years of age or weighing less than 25 kg: active surface area of 40 cm² per electrode, up to 50 shocks at 100 J and ECG monitoring for up to 24 h. The 100 cm external cable allows the equipment to be left pre-connected and ready in seconds. Single-use, free from latex and phthalates; individually heat-sealed packaging and 5 pairs per box. Immediate dispatch from Cahnos.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7953PW

Description

1. Commercial Introduction

Ensure safe and effective cardiopulmonary resuscitation in the smallest patients with this pair of standard paediatric defibrillator electrodes with external cable (reference Cahnos F7953PW). It is the ideal replacement and replenishment consumable for emergency services, paediatric intensive care units (PICU), ambulances and heart-safe spaces that care for children using equipment from the Philips, Agilent Hewlett-Packard and Laerdal Medical families: a single reference covers the most widespread hospital fleets of defibrillator-monitors (CodeMaster 100, XE, XL, XL+ and HeartStart 4000), simplifying consumables stock. Price per pair, individual heat-sealed packaging, immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical explanation of the equipment and procedure

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the rhythm, delivers the shock and monitors the electrocardiographic response. This paediatric model allows transthoracic external defibrillation, synchronised cardioversion and ECG monitoring (up to 24 hours), adapted to paediatric physiology.

In patients under 8 years of age or weighing less than 25 kg, it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode incorporates a reduced active surface of 40 cm² per electrode and must be used with the device’s paediatric mode switching or with the reduced energy configuration indicated in the defibrillator manual. The external cable variant (100 cm) keeps the connector accessible and allows the device to be preconnected, reducing preparation time in an emergency. The low-impedance conductive adhesive gel on medical foam with a metallic foil ensures stable adhesion, uniform current transmission and a reliable signal. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging, and placed according to the anatomical diagrams on the sachet.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) F7953PW
Patient type Paediatric: <8 years / <25 kg
Cable configuration External cable (preconnectable or lead-out), 100 cm
Radiotransparency No (standard version)
Total surface per electrode 75 cm²
Active surface per electrode 40 cm²
Adhesive ring width 0.7 cm
Supported shocks Up to 50 shocks at 100 J
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material 1 mm thick medical foam
Connection type Safety anti-shock connector compatible with Philips / Agilent HP / Laerdal equipment
ECG monitoring Up to 24 hours
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993
Primary packaging 1 pair in heat-sealed polyethylene and aluminium pouch, with laser pre-cut and easy opening
Sales format 5 pairs per box (paediatric series)
Shelf life 30 months from the date of production (see expiry date on the packaging)
Storage Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C
Composition Latex-free and phthalate-free · Single-use

3.1 Compatibility with defibrillators

Equipment model Factory reference Observations
CodeMaster 100 M2475B Direct connection
CodeMaster XE M1724A Direct connection
CodeMaster XL M1723A / M1723B Direct connection
CodeMaster XL+ M1722A / M1722B Direct connection
HeartStart 4000 M5500B Paediatric function and energy in manual setting
HeartStream / HeartStart XL M4735A Paediatric function and energy in manual setting
HeartStream / HeartStart XLT M3500B Paediatric function and energy in manual setting
HeartStart MRx M3535A / M3536A With hands-free electrode cable M3508A
Laerdal AED Trainer 2 – Direct connection (training)

Note: with HeartStart 4000, XL/XLT and MRx do not use in fully automatic defibrillators; the paediatric function and energy are adjusted manually. Always verify correct insertion of the connector into the device socket before clinical use.

4. Equivalences and Cross-References

Reference F7953PW corresponds to a standard paediatric multifunction electrode with external cable for the Philips CodeMaster (HP/Agilent) and Laerdal Medical defibrillator families indicated above. After verifying manufacturer sources and regulatory databases (GUDID and official catalogues), the following cross-references with confirmed codes have been identified. In no case is there an official equivalence table validated by the manufacturer for this reference; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Philips Healthcare Paediatric multifunction radiotransparent electrodes (plug-in connection) M3719A / 989803125411 Comparable by category (not interchangeable 1:1) Original manufacturer reference for the same compatibility family (M1722A/B, M1723A/B, M1724A, M2475B, M3500B, M4735A, M5500B, M3535A/M3536A). Code confirmed in GUDID and on the official Philips website. Its datasheet directs it to infants <10 kg, with short cable and conductive surface of 50 cm²; verify size, surface and connector before replacement.
Cardinal Health (Covidien) Medi-Trace Cadence paediatric RTS (radiotransparent) 22661P Comparable by category (not interchangeable 1:1) Paediatric radiolucent pair (barrel connector compatible with Philips HP) for the CodeMaster XL+ (M1722A/B, M1723A/B), HeartStream XLT (M3500B), HeartStart XL (M4735A), MRx and HeartStart 4000 (M5500B) equipment family. Code confirmed in GUDID (DI 20884527022356) and in authorised distribution catalogues; verify connector, cable and surfaces before use.
Nissha Medical Technologies (HeartSync) Paediatric defibrillation pad for Philips 6600066H (PEDIATRIC-PHILIPS, D321) Comparable by category (not interchangeable 1:1) Paediatric radiolucent pair for the HeartStart XL/T, XL+, MRx and Intrepid family; total surface of 78.4 cm² with tin and tin-copper conductive element; packaging per pair with external cable in heat-sealed bag. Code confirmed in the manufacturer’s official catalogue; not suitable for use with AED: verify compatibility with the exact device model.

There is no equivalence table validated by the manufacturer for this reference; consult the Cahnos technical department before use in tendering.

5. Selection tips and variants of interest

  • Select according to the patient: this paediatric reference is for children under 8 years of age or weighing less than 25 kg. For patients over 25 kg, use the adult version of the same connector family (F7953W).
  • Choose the cable configuration according to your workflow: the external cable of this reference allows the device to be preconnected and ready in seconds. If you prefer a cleaner placement with integrated cable, the standard version with internal cable (F7953P) is available. For imaging requirements without artefacts (X-ray or CT during care), consider the radiolucent series with internal cable (F7753P) or with external cable (F7753PW).
  • Verify the equipment configuration: on the HeartStart 4000, XL/XLT and MRx series models, the paediatric function and energy are adjusted manually; always check connector compatibility (and M3508A cable where applicable) before storing the spare part.
  • Storage: keep in a dry place between +5 °C and +35 °C and observe the expiry date stated on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date.
  • Single-use: do not reuse; one pair per patient and clinical event. Immediate availability from Cahnos with technical assistance for compatibility verification by model and connector.

Additional information

Patient type

Paediatric:

Cable type

External cable (pre-connected), 100 cm

Radiotransparency

No (standard version)

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Adhesive ring width

0.7 cm

Supported shocks

Up to 50 shocks at 100 J

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm thick medical foam

Connection type

Safety anti-shock connector compatible with Philips / Agilent HP / Laerdal

ECG monitoring

Up to 24 hours

Compatibility

CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), HeartStream XL (M4735A), XLT (M3500B), HeartStart MRx (M3535A/M3536A), Laerdal AED Trainer 2

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Reference standards

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993

Presentation

1 pair in heat-sealed bag · 5 pairs per box

Use

Single-use · Latex- and phthalate-free

Shelf life

30 months from the date of production

Storage

Dry place, +5 °C to +35 °C; operation 0 °C to +50 °C

Cable configuration

External cable (preconnectable or lead-out), 100 cm

Composition

Latex-free and phthalate-free · Single-use