Description
1. Commercial Introduction
Keep your Corpuls defibrillator-monitor always ready to attend to the smallest patients as well. This pair of radiopaque paediatric defibrillation electrodes with external lead (lead out), reference F7965PW/NG from the Italian manufacturer FIAB (FIAB SpA, Vicchio, Florence), is the consumable indicated for paediatric care with Corpuls platform equipment: it guarantees optimal shock delivery and reliable monitoring of the emergency electrocardiogram, even when the patient must undergo imaging tests.
Its bag-type packaging is specially designed for positioning on board the defibrillator, so that the device can be transported and deployed in the shortest possible time. A decisive advantage in ambulances, emergency services, intensive care units and any clinical environment with Corpuls equipment.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables emergency ECG monitoring. This pair is indicated for paediatric patients in external defibrillation, synchronised cardioversion and electrocardiographic recording, adapted to paediatric physiology.
The distinguishing feature of this reference is its condition as a radiopaque electrode: it does not interfere with the reading of imaging tests and remains functional without needing to be removed from the patient, something especially valuable in prehospital care and in critically ill patients who require X-ray, CT or fluoroscopy during transfer or in hospital. The external lead (lead out) configuration leaves the connector accessible outside the sealed bag, allowing the pair to be connected to the device immediately and stably, without handling the packaging at the critical moment. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7965PW/NG |
| Packaging | 5 pairs per box |
| Units per box (web) | 5 |
| Compatible with | Corpuls |
Relevant technical data
| Brand | FIAB (FIAB SpA – Vicchio, Florence, Italy) |
| SKU Cahnos | FIAB-F7965PW-NG |
| Product type | Pair of paediatric multifunction defibrillation electrodes |
| Target population | Paediatric |
| Radiopacity | Yes (radiopaque electrodes) |
| Cable configuration | External cable (lead out) |
| Packaging | Bag suitable for positioning on board the defibrillator |
| Presentation | Sold per pair; 5 pairs per box |
| Use | Single-use, disposable |
Note: the highlighted technical data correspond to the verified information in the manufacturer’s catalogue; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in a tender.
4. Equivalences and Cross-References
Reference F7965PW/NG is the original FIAB code for this pair of radiopaque paediatric electrodes with external lead compatible with the Corpuls platform (SKU Cahnos FIAB-F7965PW-NG). The connector, analysis algorithm and energy management of each defibrillator are proprietary, so there is no equivalence table validated by the manufacturer that authorises the replacement of these electrodes with patches from other brands without prior verification: any replacement must be validated against the technical data sheet and instructions for use of the defibrillator, and consulted with the Cahnos technical department before using it in a tender.
Within the Cahnos catalogue there are related references in the same connector family for Corpuls equipment: the F7965W/NG (radiopaque adult with external lead, FIAB), the F7965 (standard adult with internal lead), the F7965/PLUS (pre-connected standard adult) and the F7965P (paediatric with internal lead, original replacement 05120.3 / corPatch easy Pediatric). They are not interchangeable with one another as the lead configuration differs and, in the paediatric case, the energy management.
5. Selection tips and variants of interest
Confirm the device model: verify that your defibrillator-monitor belongs to the Corpuls platform and that the external lead connector fits correctly into the electrode socket before clinical use. If in doubt, contact the Cahnos technical department stating the model and serial number of the device.
Radiopaque advantage: if your workflow includes X-rays, CT or fluoroscopy during care, this radiopaque version avoids having to remove the electrode and maintains continuous monitoring. If you do not need this feature and prefer a pre-connected configuration, consider reference F7965P (paediatric with internal lead).
Adult version: for the adult population with Corpuls equipment, the corresponding radiopaque variant with external lead is reference F7965W/NG; do not confuse the two sizes when placing the order.
Storage and expiry: always check the date printed on the packaging and store in a dry, protected place; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity. As a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock by expiry date (FIFO).
The names, brands and models cited belong to their respective owners. Product without published price: sale on quotation.