Description
1. Commercial Introduction
Ensure safe and effective cardiac care for the youngest patients with this pair of radiotransparent paediatric defibrillator electrodes with external cable (reference F7752PW), a high-reliability consumable compatible with Physio-Control LIFEPAK defibrillators/monitors and Mindray BeneHeart equipment. Designed for emergency departments, paediatric intensive care, operating theatres, haemodynamics and patient transport, this electrode combines the advantages of the radiotransparent series (artefact-free imaging control) with the operability of the pre-connected external lead-out cable, which keeps the device always ready for action. A cost-optimised solution, compliant with European medical device standards and latex- and phthalate-free.
2. Technical explanation of the equipment and procedure
Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them, the device analyses the rhythm, delivers therapy and monitors the response. This paediatric model enables external transthoracic defibrillation, synchronised cardioversion, non-invasive transcutaneous cardiac pacing and ECG monitoring (up to 24 h), adapted to paediatric physiology (children under 8 years or 25 kg). Its radiotransparent nature —electrode and cable— prevents artefacts in imaging studies, so it can remain in place during X-ray-guided procedures without interfering with diagnosis. The 100 cm external lead-out cable variant allows the connector to be left accessible and the pad ready, reducing preparation time in emergencies. The low-impedance conductive adhesive gel on medical foam with a metallic film ensures uniform current distribution and a reliable signal. They are single-use: they must be replaced after each procedure or upon reaching the expiry date printed on the packaging, and applied following the anatomical diagrams (sternal and apical position).
3. Technical Specifications
Radiotransparent paediatric multifunction electrode from the EuroDefiPads paediatric series, in its 100 cm external lead-out cable variant.
| Field | Specification |
| Reference Cahnos (SKU) | F7752PW |
| Product type | Pair of paediatric multifunction defibrillator electrodes, radiotransparent, with external lead-out cable |
| Indicated population | Children under 8 years or weighing less than 25 kg |
| Cable | 100 cm, external (lead-out / pre-connected) |
| Radiotransparency | Radiotransparent electrode and cable, for artefact-free imaging |
| Functions | Defibrillation, synchronised cardioversion, non-invasive external pacing and ECG monitoring (max. 24 h) |
| Supported shocks | 50–100 J (paediatric series) |
| Total / active area (per electrode) | 75 cm² total / 40 cm² active |
| Conductive gel | Low-impedance conductive adhesive gel |
| Backing material | Medical foam (1 mm) with conductive metal foil |
| Connector | QUIK-COMBO (depending on the device model) |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium pouch; 5 pairs per box (paediatric series) |
| Use | Single-use, disposable; latex-free and phthalate-free |
| Shelf life | 30 months from date of manufacture (check printed expiry date) |
| Conditions of use and storage | Operating temperature from 0 °C to +50 °C; store in a dry place between +5 °C and +35 °C |
| Classification | Medical device class IIb (Directive 93/42/EEC and amendments) |
| Regulatory standard | ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10 |
Main documented compatibility:
| Manufacturer | Compatible models |
| Physio-Control / Medtronic | LIFEPAK 9 (with QUIK-COMBO adapter), LIFEPAK 10, LIFEPAK 12, LIFEPAK 15, LIFEPAK 20 |
| Mindray | BeneHeart D1, BeneHeart D3, BeneHeart D6 |
The same family documents compatibility with other devices in the range (Bexen Cardio REANIBEX, Cardioline ELIFE 700, Comen), according to the manufacturer’s technical data sheet; always verify correct connector insertion before clinical use.
4. Equivalences and Cross-References
This electrode (SKU F7752PW) is a consumable compatible with the devices listed, not an original factory spare part. The correspondence with the device manufacturers’ references is as follows; any comparison between brands should be understood as comparable at category level, not 1:1 interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Stryker / Physio-Control | Pediatric EDGE System RTS (Radiotransparent) Electrodes with QUIK-COMBO Connector (original equipment) | 11996-000090 | Comparable by category (not interchangeable 1:1) | Factory original for LIFEPAK 12, 15 and 20 defibrillators/monitors; QUIK-COMBO connector, radiotransparent, paediatric use 0–15 kg; enables defibrillation, pacing and ECG. Code confirmed in the official Stryker store, authorised distributors and GUDID (UDI 00721902195037). Not suitable for equipment of other brands. |
| Mindray | MR61 – Paediatric multifunction electrode (original spare part for BeneHeart series) | 115-040518-00 | Comparable by category (not interchangeable 1:1) | Mindray original for BeneHeart D1, D2, D3, D5, D6 and C series defibrillators; paediatric population under 25 kg; Mindray proprietary connector and algorithm, not compatible with the QUIK-COMBO socket of LIFEPAK devices. Code confirmed in authorised distributors and manufacturer reference sources. |
There is no equivalence table validated by Physio-Control/Stryker or Mindray that authorises the replacement of original references 11996-000090 or 115-040518-00 with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any replacement must be validated against the defibrillator’s technical data sheet and IFU. Consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
Confirm the device model and connector: this pair corresponds to Physio-Control LIFEPAK 9 (with QUIK-COMBO adapter), 10, 12, 15 and 20 defibrillators/monitors, and to Mindray BeneHeart D1, D3 and D6 devices. Verify the reference and expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after a procedure.
Choose the variant according to the workflow: the external cable (lead-out) of this model allows the equipment to be pre-connected and ready in seconds; if you prefer an internal cable, reference F7752P is available (same paediatric radiotransparent series). For standard use without a radiotransparency requirement, consider F7952PW (standard paediatric lead-out) or F7952P (standard paediatric with internal cable). For AED equipment with automatic energy reduction, references F7952WPL and F7952PL (200 J → 50 J) are the indicated ones. The adult version of this same series is the F7752W.
Maintenance and provisioning: manage stock rotation by expiry date (approx. 30 months) and always keep a spare pair next to the equipment in centres with paediatric populations. For volume orders or tenders, contact the technical department at Cahnos stating the exact defibrillator model.