Paediatric AED defibrillation electrode with limited energy 200 J → 50 J, internal cable 120 cm (Ref. F7952PL) – Compatible replacement Physio-Control LIFEPAK 500 pink connector, LIFEPAK 1000, EXPRESS and CR Plus

62,50 €

Pair of paediatric defibrillation electrodes with limited energy (Ref. F7952PL) with internal cable of 120 cm, replacement compatible with Physio-Control LIFEPAK 500 AED Biphasic with pink connector, LIFEPAK 1000, LIFEPAK EXPRESS and LIFEPAK CR Plus AEDs. When connecting these pads, the limited-energy system reduces the device discharge from 200 J to ≈50 J on the patient, the recommended dose for children aged 1 to 8 years or weighing less than 25 kg. Disposable multifunction electrodes with QUIK-COMBO pink connector, low-impedance conductive adhesive gel, active surface of 40 cm² per electrode and ECG monitoring up to 24 h. Single-use, non-sterile, latex-free and phthalate-free; check the printed expiry date before replacement. Essential replacement for schools, nurseries and heart-safe points with a child population.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7952PL

Description

1. Commercial Introduction

Ensure safe and effective care for the smallest patients with this pair of paediatric limited-energy defibrillation electrodes, reference Cahnos F7952PL, compatible with Physio-Control LIFEPAK 500 AED Biphasic with pink socket, LIFEPAK 1000 AED, LIFEPAK EXPRESS AED and LIFEPAK CR Plus AED. It is the clinical replacement indicated for schools, nurseries, sports centres, paediatric clinics and any public access defibrillation point with children present: when these electrodes are connected, the defibrillator delivers a shock adapted to paediatric physiology without the need for manual configuration. A reliable, cost-optimised solution compliant with European medical device standards, designed to keep the equipment always operational and ready for the paediatric population.

2. Technical explanation of the equipment and procedure

The LIFEPAK family of automated external defibrillators (AEDs) analyse the heart rhythm through disposable multifunction electrodes. When this pair of paediatric electrodes is connected, the limited-energy system built into the patch itself reduces the shock that the device would deliver in adult configuration: 200 J of defibrillator output becomes approximately 50 J at the patient, a dose adapted to the paediatric myocardium according to international cardiopulmonary resuscitation guidelines (1:4 energy divider). This variant with a 120 cm internal cable ensures a robust connection during the intervention: the protective liner is removed, the patches are applied following the anatomical diagrams on the packaging (sternal and apical positions) and the device is ready for rhythm analysis, defibrillation and ECG monitoring during care (up to 24 h). The electrodes incorporate low-impedance conductive adhesive gel on a medical foam backing with a conductive metal foil, ensuring a reliable signal and uniform current distribution. They are single-use: they must be replaced after each intervention or upon reaching the printed expiry date on the packaging.

3. Technical Specifications

Paediatric multifunction limited-energy electrode from the EuroDefiPads paediatric series, in its 120 cm internal cable variant for connection to the pink socket of LIFEPAK equipment.

Reference Cahnos (SKU) F7952PL
Compatible brand Physio-Control (LIFEPAK equipment)
Compatible models LIFEPAK 500 AED BIPHASIC with pink socket, LIFEPAK 1000 AED; same family documented for LIFEPAK EXPRESS and LIFEPAK CR Plus
Product type Paediatric multifunction defibrillation electrode, QUIK-COMBO pink socket connector, internal cable
Indicated population Children aged 1 to 8 years or weighing less than 25 kg (55 lb)
Energy Limited energy for paediatric use: reduction from 200 J (device output) to ≈50 J at the patient; supported shock range 50–100 J
Cable 120 cm, internal cable
Functions Defibrillation, rhythm analysis and ECG monitoring (max. 24 h)
Total / active surface area (per electrode) 75 cm² total / 40 cm² active (paediatric series)
Conductive gel Low-impedance conductive adhesive gel
Backing material Medical foam (1 mm) with conductive metal foil
Use Single-use, disposable; non-sterile; latex-free and phthalate-free
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 5 pairs per box (paediatric series)
Shelf life Approx. 30 months from date of manufacture (check printed expiry date)
Conditions of use and storage Operating temperature from 0 °C to +50 °C; store in a dry place between +5 °C and +35 °C
Classification Medical device class IIb (Directive 93/42/EEC and amendments)
Regulatory standard ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993

Compatibility note: the limited-energy function requires biphasic equipment with a pink connector (LIFEPAK 500 after 2002). Do not use on monophasic LIFEPAK 500 with grey connector without prior validation with the technical service.

4. Equivalences and Cross-References

This electrode (SKU F7952PL) is a consumable compatible with Physio-Control/Stryker LIFEPAK defibrillators with pink connector, not an original factory spare part. The correspondence with the equipment manufacturer’s references and with other brands in the sector is as follows; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Stryker / Physio-Control Infant/Child Reduced Energy Defibrillation Electrodes (original equipment) 11101-000016 (replacement electrode) / 11101-000017 (kit with carrying bag) Comparable by category (not interchangeable 1:1) Factory original for LIFEPAK 500 (pink connector), 1000, EXPRESS and CR Plus; same paediatric criteria (<8 years / <25 kg) and same attenuation (÷4: 200 J → ≈50 J); Stryker’s own labelling, gel and packaging. Codes confirmed in official Stryker store, authorised distributors and in GUDID (UDI 00721902629013).
ZOLL Medical Pedi·padz II (pre-connected paediatric electrodes) 8900-0810-01 Comparable by category (not interchangeable 1:1) Paediatric range 0–8 years / <25 kg with 50/70/85 J levels selected by the AED; proprietary connector and algorithm of ZOLL (AED Plus and AED Pro); not suitable for LIFEPAK devices. Code verified in GUDID (UDI 00847946001438).
Philips Infant/Child Reduced-Energy Defibrillator Pads (for HeartStart FR2 / FR2+) M3870A (also 989803108851) Comparable by category (not interchangeable 1:1) Reduces energy from 150 J to 50 J; proprietary connector and algorithm Philips for FR2 (M3840A/M3841A) and FR2+ (M3860A/M3861A); not compatible with LIFEPAK devices. Code verified in GUDID (UDI-DI 00884838023734) and on the official Philips website.

There is no equivalence table validated by Physio-Control/Stryker that authorises the substitution of original references 11101-000016 / 11101-000017 with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any substitution must be validated against the technical data sheet and IFU of the defibrillator. Within the Cahnos catalogue there are comparable families for other equipment in the same category (paediatric AED electrodes with limited energy), such as F7950PL (Philips), F7957PL (Cardiac Science), F7959PL (CU Medical i-PAD) or F7966WPL (Defibtech), all comparable by category and not interchangeable 1:1 with each other. Consult the Cahnos technical department before use in tenders.

5. Selection tips and variants of interest

Confirm the model and connector of the device: this pair of electrodes corresponds to the LIFEPAK 500 AED Biphasic with pink connector, LIFEPAK 1000, LIFEPAK EXPRESS and LIFEPAK CR Plus AEDs. It is not valid for monophasic LIFEPAK 500 with grey connector or for other models without prior connector validation. Check the reference on the packaging and the expiry date before replacement.

Paediatric provision: in centres with a child population always keep a pair of paediatric electrodes with the AED; energy is reduced automatically when connecting the limited-energy pad, without manual configuration.

Variants within the Cahnos catalogue: F7952WPL (same reduction 200 J → 50 J with external lead-out cable of 120 cm to keep the device pre-connected), F7952P (standard paediatric with internal cable, without energy reduction) and F7952PW (standard paediatric lead-out, without reduction). For equipment of other brands, consider F7950PL (Philips), F7957PL (Cardiac Science), F7959PL (CU Medical) or F7966WPL (Defibtech).

Maintenance: manage stock rotation by expiry (approx. 30 months) and always replace the electrode after use or expiry. For volume orders or tenders, contact the Cahnos technical department indicating the exact model of the defibrillator.

Additional information

Reference

F7952PL

Compatibility

Physio-Control (LIFEPAK equipment)

Compatible models

LIFEPAK 500 AED Biphasic (pink socket), LIFEPAK 1000 AED, LIFEPAK EXPRESS AED, LIFEPAK CR Plus AED (QUIK-COMBO pink socket connector)

Indicated population

Children aged 1 to 8 years or weighing less than 25 kg (55 lb)

Energy reduction

200 J (device output) → ≈50 J at the patient

Supported shocks

50–100 J

Cable length

120 cm, internal cable

Connector

QUIK-COMBO pink socket

Total surface

75 cm² per electrode (paediatric series)

Active surface

40 cm² per electrode (paediatric series)

ECG monitoring

Max. 24 h

Conductive gel

Low-impedance conductive adhesive gel

Backing material

Medical foam (1 mm thick)

Use

Single-use, disposable, non-sterile

Presentation

1 pair in heat-sealed polyethylene and aluminium bag; 5 pairs per box

Shelf life

Approx. 30 months from date of manufacture (check printed expiry date)

Storage conditions

Dry place between +5 °C and +35 °C; operating from 0 °C to +50 °C

Classification

Class IIb medical device (Directive 93/42/EEC and amendments)

Product type

Paediatric multifunction limited-energy defibrillation electrode, 1 pair (2 pieces), disposable

Energy

Paediatric limited energy: reduction from 200 J (device output) to ≈50 J at the patient (divider ÷4); supported shocks 50–100 J

Cable

120 cm, internal

Functions

Defibrillation, rhythm analysis and ECG monitoring (max. 24 h)

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Conductive material

Metal foil

Composition

Latex-free and phthalate-free

Operating conditions

Operating from 0 °C to +50 °C

Storage

Dry place, between +5 °C and +35 °C

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993