Description
1. Introduction
Ensure paediatric care for your automated external defibrillator with the limited-energy paediatric defibrillator electrode compatible with the CU Medical Systems brand, models i-PAD NF1200 and NF1201. It consists of a pair of pre-connected, disposable, single-use self-adhesive pads designed to allow the device to deliver a safe shock adapted to the physiological characteristics of paediatric patients. An essential spare part for schools, sports centres, ambulances, civil protection and any care point equipped with an AED from the i-PAD series.
2. Technical explanation of the procedure
The limited-energy paediatric electrodes are indicated for external defibrillation of children aged 1 to 8 years or weighing less than 25 kg. When the pair of paediatric electrodes is connected to the i-PAD NF1200 / NF1201 AED, the device automatically detects them and reduces the shock energy to 50 joules, avoiding the energy overdose that would result from using the adult configuration. The pads are pre-connected (cable already assembled), which speeds up rescue preparation: simply peel off the protective backing, place them following the anatomical diagrams on the packaging and let the device analyse the rhythm and deliver therapy. The low-impedance conductive adhesive gel ensures optimal contact with the chest skin and efficient current transmission, while the medical foam backing keeps the electrode stable during resuscitation. They are single-use: after each use they must be removed and replaced with a new pair.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | F7959WPL |
| Product type | Paediatric defibrillator electrode, limited energy (low energy) |
| Original factory reference that this reproduces | CUA0512P (CU Medical Systems) |
| Presentation | 1 pair of pre-connected, disposable electrodes |
| Target population | Children aged 1 to 8 years or weight under 25 kg |
| Compatibility | CU Medical Systems i-PAD NF1200 (semi-automatic) and i-PAD NF1201 (automatic). Not compatible with SP1/SP2, CU-SPR or NFK200 series. |
| Energy delivered | Automatic reduction to 50 J when paediatric electrodes are detected |
| Connection | Pre-connected (assembled cable) with anti-shock connector |
| Conductive gel | Low-impedance adhesive gel |
| Backing material | Medical foam (FOAM) |
| Composition | Latex-free and phthalate-free |
| Use | Single patient, non-reusable |
| Shelf life | Approximately 2 years from manufacture (check expiry on packaging) |
| Storage | Dry place, at room temperature (5–35 ºC approx.); do not use if packaging is open or damaged |
Technical note: the compatibility data, target population and energy reduction (50 J) correspond to the official CU Medical Systems documentation for the paediatric electrodes of the i-PAD NF1200/NF1201; before placing your order, confirm the exact model of your device.
4. Equivalences and Cross-References
This compatible reference reproduces the function of the original factory paediatric electrode from CU Medical Systems (CUA0512P). CU Medical does not publish an official equivalence table authorising third-party pads for the i-PAD NF1200/NF1201; the listed alternatives share the same type (limited-energy paediatric electrode for AED) and are classified as comparable by category, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| CU Medical Systems | Original paediatric electrode i-PAD NF1200 / NF1201 | CUA0512P | Comparable by category (not interchangeable 1:1) | It is the original factory electrode that this compatible reference replaces: pre-connected, automatic reduced energy to 50 J, children 1–8 years / <25 kg. Verify connector fit and packaging expiry date. |
| ZOLL | Pedi-Padz II (AED Plus / AED Pro) | 8900-0810 | Comparable by category (not interchangeable 1:1) | Paediatric 0–8 years / <25 kg, hydrogel, pre-connected, levels 50/70/85 J; connector and management electronics exclusive to ZOLL. |
| Philips | Infant/Child Reduced Energy Pads (HeartStart FR2 / FR2+) | M3870A | Comparable by category (not interchangeable 1:1) | Reduced energy for children <8 years / <25 kg; exclusive to the HeartStart FR2/FR2+ series (M3840A/M3841A/M3860A/M3861A); not interchangeable 1:1. |
| Philips | HeartStart OnSite / HS1 SMART Pads Infant/Child | M5072A | Comparable by category (not interchangeable 1:1) | Cartridge that reduces the shock from 150 to 50 J for the paediatric population; device-specific SMART detection system; not interchangeable. |
There is no equivalence table validated by CU Medical Systems that cross-references the CUA0512P reference with third-party electrodes; consult the technical department before using in a tender. Before accepting any alternative, each of the following must be verified individually: device connector, automatic paediatric energy detection (50 J), target population (1–8 years / <25 kg) and packaging expiry date.
5. Selection tips and variants of interest
- Identify the exact model: these electrodes are compatible with the CU Medical i-PAD NF1200 (semi-automatic) and NF1201 (automatic) AEDs. They are not compatible with the SP1/SP2, CU-SPR or NFK200 series; if your device is from another series, consult the appropriate reference.
- Manage expiry: the pads have an approximate shelf life of 2 years. Establish a FIFO stock rotation and check the packaging date during periodic AED checks; replace the pair before its expiry even if it has not been used.
- Always keep a spare pair: the AED must remain operational after each use. Immediately replace the used electrodes and verify the device’s self-test.
- Recommended accessories: also check the condition of the i-PAD NF1200 battery (original reference CUSA0601F) and the adult electrode pair to cover the entire patient population.
- Staff training: practise placement using the packaging diagrams and the device’s training mode to reduce response times in a real emergency.
- Volume orders and tenders: contact the Cahnos technical department indicating the exact AED model and required quantities; we will confirm references, expiry dates and commercial terms before finalising the order.