Energy-limited paediatric AED defibrillator electrode for CU Medical Systems i-PAD NF1200 / NF1201 – Replacement 1 pair (Ref. F7959PL)

62,50 €

Pair of energy-limited paediatric defibrillator electrodes, compatible with CU Medical Systems i-PAD NF1200 and i-PAD NF1201 AEDs (Saver series). Designed for children aged 1 to 8 years or weighing less than 25 kg, they automatically reduce the shock to 50 J when connected, ensuring safe resuscitation in paediatric patients. They incorporate a low-impedance conductive adhesive gel, are free from latex and phthalates, and are supplied in a heat-sealed package. Single-use product; check the printed expiry date. Reference Cahnos F7959PL, a replacement that replicates the function of the original CU Medical CUA0512P electrode. Ideal for schools, nurseries, sports centres, ambulances and defibrillation points with children present.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7959PL

Description

1. Commercial Introduction

Ensure the paediatric care of your automated external defibrillator (AED) with this pair of paediatric defibrillation electrodes with limited energy, compatible with the i-PAD NF1200 (semi-automatic) and i-PAD NF1201 (automatic) models from CU Medical Systems, Saver series. It is an essential clinical replacement for schools, nurseries, sports centres, paediatric practices and any public access defibrillation programme with a child population: when connected, the device delivers a safe shock adapted to the physiological characteristics of the smallest patients.

With reference Cahnos F7959PL, this product is designed to replicate the function of the original factory paediatric electrode CU Medical Systems CUA0512P. Its installation is quick and requires no configuration: connect the connector to the device, remove the protective liner, apply the pads following the anatomical diagrams, and the AED is ready for analysis and therapy.

2. Technical explanation of the equipment and procedure

The CU Medical Systems i-PAD NF1200 and NF1201 automated external defibrillators analyse the heart rhythm through the multifunction electrodes connected to the patient. When a pair of paediatric limited-energy electrodes is used, the device automatically detects this and reduces the shock energy to 50 joules, avoiding delivering the energy intended for adults to a child’s heart. This is essential in paediatric resuscitation, where excess energy can cause myocardial damage.

The electrodes are indicated for children aged 1 to 8 years or weighing less than 25 kg (55 lb). They incorporate low-impedance conductive adhesive gel that ensures optimal skin contact and efficient current transmission, along with a medical foam backing that keeps the electrode stable during resuscitation. The pads are placed following the anatomical diagrams on the packaging, and once used must be removed and replaced with a new pair, as they are single-use.

3. Technical Specifications

Parameter Specification
Brand CU Medical Systems
Compatible model i-PAD NF1200 (semi-automatic) and i-PAD NF1201 (automatic), Saver series
Type Paediatric defibrillator electrode, limited energy
Reference Cahnos (SKU) F7959PL
Original factory reference that this reproduces CUA0512P (CU Medical Systems)
Electrode type Limited-energy paediatric multifunction, 1 pair (2 pieces), disposable
Indicated population Children aged 1 to 8 years or weight under 25 kg (55 lb)
Energy delivered Automatic reduction to 50 J when paediatric electrodes are detected
Connection CU Medical proprietary connector for connection to the unit port
Functions Rhythm analysis, defibrillation and ECG monitoring
Conductive gel Low-impedance conductive adhesive gel
Backing material Medical foam (FOAM)
Composition Latex-free and phthalate-free
Use Single patient, non-reusable
Shelf life Approximately 2 years from manufacture (check expiry on packaging)
Storage Dry place, at room temperature (5–35 ºC approx.); do not use if packaging is open or damaged
Sterility Non-sterile
Presentation 1 pair (2 electrodes)
Storage Heat-sealed paper and aluminium pouch
Regulatory standard Medical device with CE/MDR marking; verify packaging labelling

Technical note: the compatibility data, target population and energy reduction (50 J) correspond to the official documentation from CU Medical Systems for the paediatric electrodes of the i-PAD NF1200 / NF1201; before placing the order, confirm the exact model of your device.

4. Equivalences and Cross-References

The original factory reference for this paediatric consumable is CUA0512P (CU Medical Systems, paediatric electrode for i-PAD NF1200 / NF1201), verified in catalogues and authorised distributors of the manufacturer. The electrode we offer (F7959PL) is designed to be functionally compatible with these devices; if your purchasing process requires an original manufacturer part, request the reference CUA0512P.

CU Medical Systems does not publish an official equivalence table authorising third-party electrodes for its devices: the connector, analysis algorithm and energy management are proprietary. Any comparison with other brands should be understood as comparable at category level, not 1:1 interchangeable, verifying connector, energy range and algorithm before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
CU Medical Systems Original paediatric electrode i-PAD NF1200 / NF1201 CUA0512P Comparable by category (not interchangeable 1:1) It is the original factory electrode that this compatible reference replaces: automatic reduced energy to 50 J, children 1–8 years / <25 kg. Verify connector fit and packaging expiry.
ZOLL Medical Pedi-Padz II (AED Plus / AED Pro) 8900-0810-01 Comparable by category (not interchangeable 1:1) Paediatric 0–8 years / <25 kg, hydrogel, levels 50/70/85 J; connector and management electronics exclusive to ZOLL.
Philips Infant/Child Reduced Energy Pads (HeartStart FR2 / FR2+) M3870A Comparable by category (not interchangeable 1:1) Reduced energy for children <8 years / <25 kg; exclusive to the HeartStart FR2/FR2+ series (M3840A/M3841A/M3860A/M3861A).
Philips HeartStart OnSite / HS1 SMART Pads Infant/Child M5072A Comparable by category (not interchangeable 1:1) Cartridge that reduces the shock from 150 to 50 J for paediatric population; unit’s own SMART detection system.
Cardiac Science Powerheart G3 Pediatric Electrode Pads 9730-002 Comparable by category (not interchangeable 1:1) Reduced energy for patients under 8 years or under 25 kg; exclusive to Powerheart G3 series (9200/9300), with its own connector and attenuation.
Defibtech Lifeline DDU-1XX Pediatric Rescue Pads DDP-200P Comparable by category (not interchangeable 1:1) Integrated energy attenuator for <8 years / <25 kg; proprietary Defibtech connector; verified in GUDID/FDA (UDI-DI 00815098020430).

There is no equivalence table validated by CU Medical Systems that cross-references the CUA0512P reference with third-party electrodes; consult the technical department of Cahnos before using any cross-reference in a tender. Before accepting any alternative, each must be verified one by one: device connector, automatic paediatric energy detection (50 J), target population (1–8 years / <25 kg) and packaging expiry.

5. Selection tips and variants of interest

  • Identify the exact model: these electrodes are compatible with CU Medical AEDs i-PAD NF1200 (semi-automatic) and NF1201 (automatic). They are not compatible with the SP1/SP2, CU-SPR or NFK200 series; if your device is from another series, consult the appropriate reference.
  • Check the reference and expiry: verify on the packaging the code CUA0512P (original part) and the expiry date; do not force the installation of an expired electrode, as the gel may lose conductivity.
  • Always keep a spare pair: the AED must remain operational after each use. Immediately replace the used electrodes and verify the device’s self-test.
  • Recommended accessories: also check the condition of the i-PAD NF1200 battery (original reference CUSA0601F) and the adult electrode pair to cover the entire patient population.
  • Variants within the Cahnos catalogue: F7959WPL (pre-connected paediatric electrode for the same device, same family), F7958PL (reduced energy paediatric electrode for Paramedic CU-ER1), F7952PL (limited energy paediatric electrode for Physio-Control), F7950PL (limited energy paediatric electrode for Philips FR2/FR2+).
  • Stock management: establish a FIFO rotation by expiry and replace the electrode after use or expiration. For volume orders or tenders, contact the technical department of Cahnos indicating the exact model and serial number of the device.

Additional information

Manufacturer reference

CUA0512P (CU Medical official accessories catalogue)

Compatible models

i-PAD NF1200 (semi-automatic) and NF1201 (automatic) – Saver family

Product type

Multifunction paediatric, pre-connected (1 pair / 2 pieces)

Indicated population

Children aged 1 to 8 years or weighing less than 25 kg (55 lb)

Energy

Automatic reduction to 50 J when paediatric electrodes are detected

Functions

Rhythm analysis, defibrillation and ECG monitoring

Conductive gel

Low-impedance conductive adhesive gel

Connector

CU Medical proprietary, for connection to the unit

Shelf life

Approximately 2 years from manufacture (check expiry on packaging)

Use

Single patient, non-reusable

Sterilisation

Non-sterile

Presentation

1 pair (2 electrodes)

Not compatible with

i-PAD SP1, SP2, CU-SPR or NFK200

Original manufacturer reference

CUA0512P (CU Medical Systems)

Electrode type

Paediatric multifunction limited energy (1 pair / 2 pieces)

Target population

Children aged 1 to 8 years or weight under 25 kg (55 lb)

Compatibility

CU Medical Systems i-PAD NF1200 / i-PAD NF1201 (Saver series); not compatible with SP1/SP2, CU-SPR or NFK200

Backing material

Medical foam (FOAM)

Free from

Latex and phthalates

Storage

Heat-sealed paper and aluminium bag, dry place

Regulatory standard

Medical device with CE/MDR marking (verify packaging labelling)

Esterilidad

Non-sterile