Description
1. Commercial Introduction
Ensure the paediatric care of your automated external defibrillator (AED) with this pair of paediatric defibrillation electrodes with limited energy, compatible with the i-PAD NF1200 (semi-automatic) and i-PAD NF1201 (automatic) models from CU Medical Systems, Saver series. It is an essential clinical replacement for schools, nurseries, sports centres, paediatric practices and any public access defibrillation programme with a child population: when connected, the device delivers a safe shock adapted to the physiological characteristics of the smallest patients.
With reference Cahnos F7959PL, this product is designed to replicate the function of the original factory paediatric electrode CU Medical Systems CUA0512P. Its installation is quick and requires no configuration: connect the connector to the device, remove the protective liner, apply the pads following the anatomical diagrams, and the AED is ready for analysis and therapy.
2. Technical explanation of the equipment and procedure
The CU Medical Systems i-PAD NF1200 and NF1201 automated external defibrillators analyse the heart rhythm through the multifunction electrodes connected to the patient. When a pair of paediatric limited-energy electrodes is used, the device automatically detects this and reduces the shock energy to 50 joules, avoiding delivering the energy intended for adults to a child’s heart. This is essential in paediatric resuscitation, where excess energy can cause myocardial damage.
The electrodes are indicated for children aged 1 to 8 years or weighing less than 25 kg (55 lb). They incorporate low-impedance conductive adhesive gel that ensures optimal skin contact and efficient current transmission, along with a medical foam backing that keeps the electrode stable during resuscitation. The pads are placed following the anatomical diagrams on the packaging, and once used must be removed and replaced with a new pair, as they are single-use.
3. Technical Specifications
| Parameter | Specification |
| Brand | CU Medical Systems |
| Compatible model | i-PAD NF1200 (semi-automatic) and i-PAD NF1201 (automatic), Saver series |
| Type | Paediatric defibrillator electrode, limited energy |
| Reference Cahnos (SKU) | F7959PL |
| Original factory reference that this reproduces | CUA0512P (CU Medical Systems) |
| Electrode type | Limited-energy paediatric multifunction, 1 pair (2 pieces), disposable |
| Indicated population | Children aged 1 to 8 years or weight under 25 kg (55 lb) |
| Energy delivered | Automatic reduction to 50 J when paediatric electrodes are detected |
| Connection | CU Medical proprietary connector for connection to the unit port |
| Functions | Rhythm analysis, defibrillation and ECG monitoring |
| Conductive gel | Low-impedance conductive adhesive gel |
| Backing material | Medical foam (FOAM) |
| Composition | Latex-free and phthalate-free |
| Use | Single patient, non-reusable |
| Shelf life | Approximately 2 years from manufacture (check expiry on packaging) |
| Storage | Dry place, at room temperature (5–35 ºC approx.); do not use if packaging is open or damaged |
| Sterility | Non-sterile |
| Presentation | 1 pair (2 electrodes) |
| Storage | Heat-sealed paper and aluminium pouch |
| Regulatory standard | Medical device with CE/MDR marking; verify packaging labelling |
Technical note: the compatibility data, target population and energy reduction (50 J) correspond to the official documentation from CU Medical Systems for the paediatric electrodes of the i-PAD NF1200 / NF1201; before placing the order, confirm the exact model of your device.
4. Equivalences and Cross-References
The original factory reference for this paediatric consumable is CUA0512P (CU Medical Systems, paediatric electrode for i-PAD NF1200 / NF1201), verified in catalogues and authorised distributors of the manufacturer. The electrode we offer (F7959PL) is designed to be functionally compatible with these devices; if your purchasing process requires an original manufacturer part, request the reference CUA0512P.
CU Medical Systems does not publish an official equivalence table authorising third-party electrodes for its devices: the connector, analysis algorithm and energy management are proprietary. Any comparison with other brands should be understood as comparable at category level, not 1:1 interchangeable, verifying connector, energy range and algorithm before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| CU Medical Systems | Original paediatric electrode i-PAD NF1200 / NF1201 | CUA0512P | Comparable by category (not interchangeable 1:1) | It is the original factory electrode that this compatible reference replaces: automatic reduced energy to 50 J, children 1–8 years / <25 kg. Verify connector fit and packaging expiry. |
| ZOLL Medical | Pedi-Padz II (AED Plus / AED Pro) | 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Paediatric 0–8 years / <25 kg, hydrogel, levels 50/70/85 J; connector and management electronics exclusive to ZOLL. |
| Philips | Infant/Child Reduced Energy Pads (HeartStart FR2 / FR2+) | M3870A | Comparable by category (not interchangeable 1:1) | Reduced energy for children <8 years / <25 kg; exclusive to the HeartStart FR2/FR2+ series (M3840A/M3841A/M3860A/M3861A). |
| Philips | HeartStart OnSite / HS1 SMART Pads Infant/Child | M5072A | Comparable by category (not interchangeable 1:1) | Cartridge that reduces the shock from 150 to 50 J for paediatric population; unit’s own SMART detection system. |
| Cardiac Science | Powerheart G3 Pediatric Electrode Pads | 9730-002 | Comparable by category (not interchangeable 1:1) | Reduced energy for patients under 8 years or under 25 kg; exclusive to Powerheart G3 series (9200/9300), with its own connector and attenuation. |
| Defibtech | Lifeline DDU-1XX Pediatric Rescue Pads | DDP-200P | Comparable by category (not interchangeable 1:1) | Integrated energy attenuator for <8 years / <25 kg; proprietary Defibtech connector; verified in GUDID/FDA (UDI-DI 00815098020430). |
There is no equivalence table validated by CU Medical Systems that cross-references the CUA0512P reference with third-party electrodes; consult the technical department of Cahnos before using any cross-reference in a tender. Before accepting any alternative, each must be verified one by one: device connector, automatic paediatric energy detection (50 J), target population (1–8 years / <25 kg) and packaging expiry.
5. Selection tips and variants of interest
- Identify the exact model: these electrodes are compatible with CU Medical AEDs i-PAD NF1200 (semi-automatic) and NF1201 (automatic). They are not compatible with the SP1/SP2, CU-SPR or NFK200 series; if your device is from another series, consult the appropriate reference.
- Check the reference and expiry: verify on the packaging the code CUA0512P (original part) and the expiry date; do not force the installation of an expired electrode, as the gel may lose conductivity.
- Always keep a spare pair: the AED must remain operational after each use. Immediately replace the used electrodes and verify the device’s self-test.
- Recommended accessories: also check the condition of the i-PAD NF1200 battery (original reference CUSA0601F) and the adult electrode pair to cover the entire patient population.
- Variants within the Cahnos catalogue: F7959WPL (pre-connected paediatric electrode for the same device, same family), F7958PL (reduced energy paediatric electrode for Paramedic CU-ER1), F7952PL (limited energy paediatric electrode for Physio-Control), F7950PL (limited energy paediatric electrode for Philips FR2/FR2+).
- Stock management: establish a FIFO rotation by expiry and replace the electrode after use or expiration. For volume orders or tenders, contact the technical department of Cahnos indicating the exact model and serial number of the device.