Compatible paediatric electrodes for Medtronic Physio-Control LIFEPAK defibrillator (pink socket) – Disposable pair with energy reduction 200 J → 50 J – Ref. 55004

361,00 €

Pair of compatible paediatric electrodes (single-use) for Medtronic Physio-Control LIFEPAK defibrillators with pink socket: LIFEPAK 500 AED biphasic (pink socket), LIFEPAK 1000, LIFEPAK CR Plus and LIFEPAK Express. They incorporate an energy reduction system that converts the device output (200 J in LIFEPAK 1000/CR Plus/Express) into approximately 50 J on the patient, the recommended dose according to CPR guidelines for children under 8 years of age or weighing less than 25 kg. They comply with international regulations applicable to compatible adult electrodes, are latex-free and are manufactured in Italy. The packaging is multilingual (GB, FR, IT, ES, PT, DE, NL, SE, GR, RU).

Sales unit: 5 pares
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM55004

Description

1. Commercial Introduction

Ensure safe paediatric care with this pair of compatible paediatric electrodes intended for Medtronic Physio-Control LIFEPAK defibrillators with a pink socket. It is the replacement consumable recommended for schools, nurseries, paediatric practices, ambulances and any cardio-protected space with children present: when the paediatric pad is connected, the limited-energy system delivers a shock adapted to children’s physiology, with no need for manual configuration. It is manufactured in Italy in accordance with international regulations applicable to compatible electrodes for adults and is latex-free.

2. Technical explanation of the equipment and procedure

Automated external defibrillators (AEDs) in the LIFEPAK family with a pink socket analyse the cardiac rhythm through the disposable multifunction electrodes. For paediatric resuscitation, the CPR guidelines set the paediatric treatment limit at 8 years, which corresponds to approximately 25 kg according to standard growth curves. When this pair of paediatric electrodes is connected, the built-in energy reduction system attenuates the shock delivered by the device in adult configuration: the output of 150 J (in equipment reference 33606) or of 200 J (in equipment reference 33603) is reduced to 50 J at the patient, a dose suitable for the paediatric myocardium.

The electrodes are placed following the anatomical diagrams on the packaging (sternal and apical positions). They are single-use and disposable: they must be replaced after each intervention or when the expiry date printed on the pouch is reached. The packaging is multilingual and includes the languages GB, FR, IT, ES, PT, DE, NL, SE, GR and RU.

3. Technical Specifications

Parameter Specification
Manufacturer reference 55004
Manufacturer GIMA
Electrode type Paediatric compatible, multifunction, disposable (single-use)
Target population Paediatric – under 8 years of age or approximately 25 kg
Limited-energy system Reduction of the defibrillator output (150 J – ref. 33606 / 200 J – ref. 33603) to 50 J at the patient
Main compatibility Physio-Control – LIFEPAK 500 AED (pink socket), LIFEPAK 1000 AED, LIFEPAK CR Plus AED and LIFEPAK Express AED
Use Single-use, disposable
Composition Latex-free
Origin Made in Italy
Packaging Multilingual (GB, FR, IT, ES, PT, DE, NL, SE, GR, RU)
Sales unit 5 pairs
Device type Medical device (Medical device)
Device class II B
CND C020401
GMDN 47055

4. Equivalences and Cross-References

These compatible paediatric electrodes correspond to the manufacturer’s reference 55004 and are designed for the cited Medtronic Physio-Control LIFEPAK defibrillators with pink socket. Within the Cahnos store there are families of limited-energy paediatric electrodes for these same devices (QUIK-COMBO pink socket connections) as a comparable category reference:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Observations
Catalogue Cahnos Compatible paediatric electrodes for Medtronic Physio-Control defibrillator (product analysed) 55004 Original reference (same manufacturer) Disposable pair with energy reduction system to 50 J; latex-free; manufactured in Italy. Confirmed in the official catalogue.
Cahnos Paediatric AED electrode with limited energy and external cable (lead-out) for LIFEPAK 500 pink socket, 1000, EXPRESS and CR Plus F7952WPL Comparable by category (not interchangeable 1:1) Same paediatric criterion (<8 years / <25 kg) and same energy reduction (200 J → ≈50 J); QUIK-COMBO pink socket connector and 120 cm external cable. Connector, gel and packaging specific to the series.
Cahnos Paediatric AED electrode with limited energy and internal cable for LIFEPAK 500 pink socket, 1000, EXPRESS and CR Plus F7952PL Comparable by category (not interchangeable 1:1) Same energy reduction (200 J → ≈50 J) with 120 cm internal cable and QUIK-COMBO pink socket connector; alternative within the Cahnos catalogue for the same devices.

No official manufacturer equivalence table is available that authorises 1:1 interchange with the original Stryker/Physio-Control references (Infant/Child Reduced Energy Defibrillation Electrodes 11101-000016 / 11101-000017): the connector, the analysis algorithm and the energy management are proprietary. Any substitution must be validated against the technical data sheet and IFU of the defibrillator; consult the technical department at Cahnos before using it in tenders.

5. Selection tips and variants of interest

Confirm the device socket: this pair is for defibrillators with a pink socket: LIFEPAK 500 AED biphasic (after 2002), LIFEPAK 1000, LIFEPAK CR Plus and LIFEPAK Express. It is not valid for the monophasic LIFEPAK 500 with grey socket without prior connector validation.

Variants within the Cahnos catalogue: for the same devices you have reference F7952WPL (limited energy, 120 cm lead-out external cable) and F7952PL (limited energy, 120 cm internal cable). If the requirement is a standard paediatric electrode without energy reduction, consider F7952P (internal cable) and F7952PW (external cable); for AED equipment from other brands, the comparable limited-energy family includes F7950WPL (Philips), F7957WPL (Cardiac Science), F7959WPL (CU Medical) and F7966WPL (Defibtech).

Storage and expiry: these electrodes are single-use. Store in a dry place and respect the expiry date on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. Maintain a minimum stock per defibrillation unit and rotate stock (FIFO). For volume orders or tenders, contact the technical-commercial department at Cahnos, stating the exact defibrillator model.

Additional information

Sales unit

5 pairs

Manufacturer reference

55004

Product type

Pair of compatible paediatric electrodes, multifunction, disposable (single-use)

Target population

Paediatric – under 8 years of age or approximately 25 kg

Energy reduction

Defibrillator output (150 J – ref. 33606 / 200 J – ref. 33603) reduced to 50 J at the patient

Compatibility

Medtronic Physio-Control LIFEPAK 500 AED (pink socket), LIFEPAK 1000 AED, LIFEPAK CR Plus AED, LIFEPAK Express AED

Use

Single-use, disposable

Composition

Latex-free

Origin

Made in Italy

Packaging

Multilingual (GB, FR, IT, ES, PT, DE, NL, SE, GR, RU)

Presentation

5 pairs

CND code

C020401

GMDN code

47055

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Compatible paediatric electrodes for Medtronic Physio-Control LIFEPAK defibrillator (pink socket) – Disposable pair with energy reduction 200 J → 50 J – Ref. 55004”

Your email address will not be published. Required fields are marked *