Description
1. Introduction
Keep your defibrillator always operational with this pair of adult radiotransparent defibrillator electrodes with external cable (Ref. Cahnos F7752W). Designed as a multi-brand replacement for equipment from the Physio-Control LIFEPAK, Bexen Cardio REANIBEX, Cardioline ELIFE 700 and Mindray BeneHeart families, they simplify the stock of consumables for emergency departments, ICUs, ambulances, health centres and cardioprotected spaces. With their external cable configuration, you can connect the electrodes to the unit in seconds without opening or handling the packaging at the critical moment, and leave the patient’s chest visible for radiological imaging without interference. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.
2. Technical Explanation
These pads are disposable single-use multifunction electrodes: they perform external defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring. The low-impedance conductive adhesive gel ensures homogeneous skin contact, low interface resistance and optimal energy transmission of the shock; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to chest contours. Being radiotransparent, the electrode and its cable do not generate artefacts in fluoroscopy, CT or intraoperative monitoring, allowing the healthcare team to assess the rib cage, pacemaker or vascular access without removing the pads. The safety anti-shock connector enables direct connection to compatible units, and the external cable (connector and cable outside the bag) leaves the pair pre-connected and ready for emergency. They are single-patient use: after resuscitation they must be discarded and replaced, always respecting the packaging expiry date.
3. Technical specifications and compatibility
3.1 Technical specifications
Main features of the series of adult radiotransparent electrodes with external cable to which this reference belongs:
| Parameter | Specification |
| Reference Cahnos (SKU) | F7752W |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Electrode type | Disposable multifunction: defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring |
| Radiotransparency | Yes (electrode and cable), suitable for imaging procedures |
| Cable configuration | External cable: connector and 120 cm cable outside the bag, immediate connection |
| Total surface per electrode | 136 cm² |
| Active surface per electrode | 94 cm² |
| Adhesive ring width | 0.7 cm |
| Supported shocks | Up to 50 shocks at 360 J |
| ECG monitoring | Max. 24 h |
| Composition | Medical foam (1 mm), low-impedance conductive adhesive gel, metal foil and safety anti-shock connector |
| Connection type | QUIK-COMBO type platform / safety anti-shock (depending on equipment model) |
| Use | Single patient only, do not reuse |
| Latex / phthalates | Free from latex and phthalates |
| Regulatory classification | Medical device Class IIb (Directive 93/42/EEC) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Operating temperature | 0 °C to +50 °C |
| Storage temperature | +5 °C to +35 °C (dry place, not in direct sunlight) |
| Shelf life | 30 months from the date of manufacture |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box |
3.2 Compatibility with defibrillators
| Equipment brand | Compatible models | Cable / required accessories |
| Physio-Control / Stryker | LIFEPAK 9 (with QUIK-COMBO adapter), LIFEPAK 10, LIFEPAK 12, LIFEPAK 15, LIFEPAK 20 and LIFEPAK 20E | QUIK-COMBO connector |
| Bexen Cardio | REANIBEX-200, REANIBEX-300, REANIBEX-500, REANIBEX-700 and REANIBEX-800 | Connector compatible with QUIK-COMBO platform |
| Cardioline | ELIFE 700 | Connector compatible with QUIK-COMBO platform |
| Mindray | BeneHeart D1 (Public / Pro), BeneHeart D3 and BeneHeart D6 | Connector compatible with QUIK-COMBO platform |
Note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your unit before clinical use.
4. Equivalences and Cross-References
Reference F7752W is a consumable compatible with the cited defibrillators, not an original spare part certified by each equipment manufacturer: the connector and energy management of each defibrillator are proprietary. After verifying official manufacturer catalogues and regulatory databases (GUDID), the following cross-references with code confirmed in public sources are identified. Any comparison between brands should be understood as comparable at category level, not 1:1 interchangeable.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Stryker / Physio-Control | EDGE System RTS (Radiotransparent) Electrodes with QUIK-COMBO Connector (original equipment) | 11996-000090 (alternative 3010188-009) | Comparable by category (not interchangeable 1:1) | Factory original for LIFEPAK 12, 15, 20 and 20E; radiotransparent, adult multifunction with QUIK-COMBO connector. Code confirmed in the official Stryker store, authorised distribution and GUDID (UDI 00721902195037). Its 0.6 m (24 in) cable is inside the packaging (not pre-connected), compared to the 120 cm external cable of this reference; labelling, gel and packaging are Stryker’s own. |
| Mindray | MR60 – Basic adult multifunction electrode (original spare part for BeneHeart series) | 115-040517-00 | Comparable by category (not interchangeable 1:1) | Original Mindray for BeneHeart D1, D3, D6 and C series defibrillators; adult >25 kg, radiotranslucent, up to 50 shocks at 360 J, proprietary Mindray connector and algorithm; not compatible with the QUIK-COMBO connector of LIFEPAK units. Code confirmed in the official Mindray pad guide and authorised distribution. |
There is no manufacturer-validated equivalence table authorising the replacement of original electrodes by third-party pads: the connector, analysis algorithm and energy management of each defibrillator are proprietary. Any replacement must be validated against the technical data sheet and instructions for use of the defibrillator; consult with the technical department of Cahnos before use in a tender.
5. Selection tips and variants of interest
Confirm the model and connector of your unit: this pair corresponds to Physio-Control LIFEPAK 9 (with QUIK-COMBO adapter), 10, 12, 15, 20 and 20E defibrillators/monitors, as well as Bexen Cardio REANIBEX, Cardioline ELIFE 700 and Mindray BeneHeart D1/D3/D6. Always verify the connector fit and the expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after an intervention.
Choose the variant according to workflow: the external cable of this model allows the unit to be pre-connected and ready in seconds; if you prefer an internal cable, reference F7752 is available (same adult radiotransparent series). For standard use without radiotransparency requirement, consider F7952W (standard adult with external cable), at lower cost. If you treat paediatric patients, paediatric radiotransparent references F7752P (internal cable) and F7752PW (external cable) are available, as well as the limited-energy paediatric version F7952WPL for AED units with automatic reduction.
Storage and expiry: store in a dry place between +5 °C and +35 °C and respect the packaging expiry date; the conductive gel may dry out and reduce its conductivity after the expiry date. As a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO). For bulk orders or tenders, contact the technical department of Cahnos indicating the exact model and serial number of your unit.








Reviews
There are no reviews yet.