Description
1. Introduction
Keep your HeartSave defibrillator always ready for emergencies with the SavePads PreConnect-Set adult/child (Ref. 35392), the original electrode pair from Metrax-Primedic in its pre-connected configuration. Designed for the HeartSave Pad, AED, AED-M, 6 and 6S equipment manufactured from serial number S.N. 739XXXXXXX, this replacement consumable is the indicated solution for emergency services, ambulances, health centres, companies and any cardio-protected space with Metrax-Primedic equipment. As it is a healthcare distribution product: request your quote from our technical-commercial department. For large orders you can request a quote.
2. Technical explanation
The SavePads electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and allows monitoring of the emergency electrocardiogram. The PreConnect configuration incorporates the connector already prepared for immediate coupling to the equipment, which eliminates assembly steps and minimises preparation time in a cardiorespiratory arrest. They are disposable single-use multifunction electrodes, suitable for both adult and paediatric patients from 1 year of age, making them a versatile solution for fleets and centres with a paediatric population. After each intervention they must be disposed of and replaced, always respecting the expiry date printed on the packaging.
3. Technical specifications and compatibility
This set covers the HeartSave platform of the Metrax-Primedic group in its generation from S.N. 739XXXXXXX. Main features:
| Reference | 35392 |
|---|---|
| Reference Cahnos (SKU) | GM35392 |
| Electrode brand | Metrax-Primedic |
| Compatible models | HeartSave Pad, HeartSave AED, HeartSave AED-M, HeartSave 6 and HeartSave 6S (from S.N. 739XXXXXXX) |
| Patient type | Adult and child (minimum 1 year) |
| Presentation | 1 pair (2 electrodes), pre-connected configuration (PreConnect) |
| Use | Single patient — do not reuse |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Kit of 2 units (1 pair) |
| Device type | Medical device |
| Device class | I |
| CND | Z12030585 |
| EAN | 8023279353921 |
4. Equivalences and Cross-References
This pair of electrodes corresponds to the family of original SavePads from the equipment manufacturer (Primedic / Metrax GmbH) for the HeartSave platform. Related references verified in authorised European technical distribution:
| Manufacturer | Family / Model | Reference | Observations |
|---|---|---|---|
| Primedic (Metrax GmbH) | Original adult SavePads — 3-point connector | 96343 | Previous generation with 3-point connector; share the HeartSave platform. Verify connector and serial number range. |
| Primedic (Metrax GmbH) | Original SavePads for HeartSave AED before 2014 | 96387 | First generation; differences in connector and packaging format. |
| Primedic (Metrax GmbH) | Original adult SavePads PreConnect (new generation, from 2014) | 97085 | Pre-connected 12-point connector; verify F code and connector generation of the equipment. |
There is no equivalence table validated by the manufacturer that cross-references this type of electrode with platforms from other manufacturers: defibrillators use proprietary connectors and discharge protocols and are not interchangeable 1:1 between brands. Always verify the model, serial number and connector type before replacing.
5. Selection tips and variants of interest
Verify the generation of your equipment: confirm the exact model and serial number printed on the defibrillator label. This set is valid for HeartSave Pad, AED, AED-M, 6 and 6S from S.N. 739XXXXXXX; do not use it on out-of-range equipment or on other platforms with a different connector.
Spare parts management: in mixed fleets, check the connector type of each unit (3-point, pre-connected 12-point or configuration of this reference) before consolidating the order and do not mix generations. Check the expiry date and integrity of the heat-sealed packaging before installation, and rotate stock by expiry date (FIFO).
Within the same Clinical platform Cahnos has the references F7760W (adult radiotransparent electrode with external cable) and F7960W (standard adult electrode with external cable) for Metrax-Primedic equipment, not interchangeable without verifying connector and serial number range.
For institutional orders, consortia, tenders or fleet maintenance, contact our technical-commercial department indicating the models and serial numbers; we will confirm compatibility before placing the order.








Reviews