Description
1. Commercial presentation
Keep your CU Medical System i-PAD NF 1200 defibrillator always ready for emergencies with this pair of original disposable adult electrodes ORIGINAL PADS, reference 33441 (SKU Cahnos GM33441). This is the replacement identified by the manufacturer as original for the i-PAD NF 1200 platform, ensuring that rhythm analysis, defibrillation and monitoring are carried out with the correct consumable and within its use-by date. It is the recommended replacement for emergency departments, ambulances, health centres, companies, sports centres and any cardioprotected area equipped with these devices.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device acquires the electrocardiogram, detects shockable rhythms (ventricular fibrillation and ventricular tachycardia) and delivers the transthoracic shock when appropriate. This adult pair is indicated for resuscitation of adult patients and connects directly to the device via its cable and connector specific to the CU Medical platform.
The pads are supplied in a heat-sealed package that keeps the conductive gel in optimal condition until the printed expiry date; they are placed following the anatomical diagrams on the package and, once used or expired, must be removed and replaced with a new pair, as they are single-use and cannot be reused. Store in a dry place and follow stock rotation by expiry date (FIFO).
3. Technical Specifications
3.1 Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Kit of 2 pieces (kit of 2 pcs) |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C020501 |
| EAN | 8809435482083 |
3.2 Available references
| Reference Cahnos (SKU) | GM33441 |
|---|---|
| Manufacturer reference | 33441 |
| Catalogue description | CU DISPOSABLE ADULT PADS for I-Pad – ORIGINAL PADS |
| Electrode type | Adult, 1 pair (2 pieces), disposable |
| Compatible equipment brand | CU Medical System |
| Compatible model | i-PAD NF 1200 |
| Use | Single-use, disposable |
| Presentation | 1 pair (2 pieces) |
Original manufacturer/distributor (Product_DB.csv catalogue). Before placing the order, confirm the exact model of your device and the connector fit.
4. Equivalences and Cross-References
The manufacturer declares this pair as ORIGINAL PADS for CU Medical System i-PAD NF 1200 devices, without publishing an official equivalence table authorising third-party pads: the connector, energy management and analysis algorithm are proprietary to the CU Medical platform. As a comparative reference from the same device manufacturer, the original adult electrode for the i-PAD NF1200/NF1201 (Saver series) is documented in authorised distribution under code CUA0903PF.
The following references share the same typology (adult defibrillation electrode for CU Medical platforms) and are classified as comparable by category, not interchangeable 1:1 without verifying the exact model of the device and the connector:
| Manufacturer / Brand | Family / Model | Reference | Equivalence level |
|---|---|---|---|
| Catalogue Cahnos | Original disposable adult electrodes for CU Medical i-PAD NF 1200 | 33441 (SKU Cahnos GM33441) | Product reference |
| CU Medical Systems | Original adult electrode i-PAD NF1200 / NF1201 (Saver series) | CUA0903PF | Comparable by category (not interchangeable 1:1) |
| Catalogue Cahnos | Compatible adult electrodes for CU Medical i-PAD NF1200 and Cmos Drake Futura | 33448 (SKU Cahnos GM33448); see also 55030 | Comparable by category (not interchangeable 1:1) |
| Catalogue Cahnos | Compatible adult electrodes with a 24-month shelf life (CU Medical platforms) | 33584 | Comparable by category (not interchangeable 1:1) |
| Catalogue Cahnos | Original disposable paediatric electrodes for CU Medical i-PAD NF 1200 | 33443 (SKU Cahnos GM33443) | Comparable by category (not interchangeable 1:1) |
Before any replacement in a tender, verify the exact AED model and the connector fit; contact the Cahnos technical department with the model and serial number of your device.
5. Selection tips and variants of interest
- Confirm the device model: this pair corresponds to the CU Medical System i-PAD NF 1200 defibrillator. Do not use it on other series in the family with a different connector without prior verification.
- Adult population: these electrodes are indicated for adult patients. For the paediatric population with the same i-PAD NF 1200 device, use reference 33443 (SKU GM33443).
- Check the expiry date: do not install an expired electrode or one with open or damaged packaging; the gel may lose conductivity and compromise the effectiveness of the shock.
- Planned replacement: as a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO method).
- For large orders you can request a quote: contact your Cahnos technical-commercial advisor for supply conditions and volume orders.