Description
1. Commercial Introduction
Keep your defibrillator always ready to act with this pair of compatible adult electrodes, specifically designed for the Cardiac Science Powerheart AED families (9200 and G3 9300 series) and GE Responder AED / AED Pro. It is the replacement consumable recommended for companies, sports centres, emergency services, ambulances and any heart-protected space equipped with these devices: a reliable, BSI-certified, cost-optimised solution manufactured in Italy.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables emergency ECG monitoring. This pair is indicated for adult patients (over 8 years or weighing more than 25 kg) and is placed following the anatomical diagrams on the packaging.
Thanks to their appropriate gel thickness and excellent adhesion, skin contact is homogeneous and energy transmission is carried out safely and effectively. They include a pair of electrodes, cable and connector, and are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging. They are latex-free.
3. Technical Specifications
| Field | Specification |
|---|---|
| Product type | Pair of compatible adult defibrillator electrodes, disposable (includes 1 pair, cable and connector) |
| Indicated population | Adults: over 8 years / more than 25 kg |
| Compatible brand | Cardiac Science and General Electric (GE) |
| Compatible models | Cardiac Science Powerheart AED 9200 series; Powerheart AED G3 9300 series (G3, G3 Plus, G3 Pro); GE Responder AED and AED Pro |
| Certification | BSI |
| Composition | Latex-free |
| Shelf life | Max. 30 months from production date |
| Packaging | Multilingual packaging: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU |
| Origin | Made in Italy |
| Device class | IIb (Directive 93/42/EEC and amendments) |
| Regulatory standard | ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-1 |
| CND | C020401 |
Available references
| Reference | Model | Sales unit |
|---|---|---|
| GM33580 | see also 55026 | kit of 2 units |
| GM55026 | COMPATIBLE PADS for defibrillator Cardiac Science, GE | 10 pairs |
Product data
| Manufacturer | GIMA |
|---|---|
| Device type | Medical device |
| Device class | II B |
| CND | C020401 |
4. Equivalences and Cross-References
These electrodes (GM33580 / GM55026) are consumables compatible with Cardiac Science Powerheart and GE Responder AED / AED Pro defibrillators. The original factory references they functionally replace in these same devices are Cardiac Science 9131-001 (Powerheart® Adult Defibrillation Pads, documented in GUDID/FDA) and, under GE numbering, 2019199-002 (listed in the GE Responder AED operator’s manual). There is no equivalence table validated by the device manufacturer that authorises interchange between brands: the connector, analysis algorithm and energy management are proprietary, so any comparison should be understood as comparable by category and not interchangeable 1:1. Always verify the connector fit with the device before clinical use.
5. Selection tips and variants of interest
Confirm the exact model of your defibrillator: this pair of electrodes corresponds to the Cardiac Science Powerheart AED 9200, Powerheart AED G3 9300 (G3, G3 Plus, G3 Pro) and GE Responder AED / AED Pro families. Check the expiry date printed on the packaging before installation and do not use expired electrodes or those with damaged packaging, as the gel could lose conductivity.
For the paediatric provision of the same devices, a paediatric version of this family is available (refs. GM33604 / GM55002). As single-use consumables, maintain a minimum stock per defibrillation unit and rotate stock by expiry (FIFO). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact model of the device.






Reviews
There are no reviews yet.