Cahnos.com Compare invoice

Pair of adult radiotransparent defibrillator electrodes with internal cable – Replacement compatible with Marquette GE defibrillators (1250/1500 First Responder, Responder 2000/3000) and Esaote (MDF, MDF Plus) · Ref. F7762

34,75 €

Pair of adult radiotransparent defibrillator electrodes with internal cable (Ref. F7762), multifunction disposable replacement compatible with Marquette GE defibrillator-monitors (1250 and 1500 First Responder, Responder 2000/3000) and Esaote (MDF, MDF Plus). Designed for defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring for up to 24 h, they incorporate low-impedance conductive adhesive gel, 1 mm medical foam backing and metal foil. Their radiotransparent construction (electrode and cable) allows imaging control without artefacts in radiology, haemodynamics and catheterisation. They withstand 50 discharges up to 360 J. Single-use medical device, free of latex and phthalates, class IIb; presentation of 10 pairs per box.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7762

Description

1. Defibrillation spare ready for emergencies

Keep your Marquette GE or Esaote defibrillator-monitor always operational with this pair of adult radiolucent defibrillator electrodes with internal cable (reference Cahnos F7762). Designed as replacements for the Marquette/Esaote family pads, they offer a reliable solution for hospital emergency departments, intensive care units, ambulances, operating theatres, haemodynamics rooms and any facility with a professional defibrillator in service. With their integrated internal cable configuration, the electrode connects directly to the equipment socket, with no loose cables during resuscitation, and its radiolucent construction keeps the patient’s chest visible for radiological imaging without interference. Available with immediate delivery from Cahnos and specialised technical support to verify compatibility by model and connector.

2. How these electrodes work with your defibrillator

These pads are disposable single-use multifunction electrodes: they perform transthoracic external defibrillation, synchronised cardioversion, non-invasive transcutaneous cardiac pacing and ECG monitoring. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the discharge energy; the inner metal foil distributes the current uniformly and the 1 mm thick medical foam backing conforms to the contours of the adult chest.

Being radiolucent, the electrode and its cable do not generate artefacts in fluoroscopy, tomography or intraoperative monitoring, allowing assessment of the rib cage, pacemaker or vascular access without removing the pads during the procedure. The recommended placement is anterolateral (sternal and apical position), with the two pads not coming into contact with each other. They are single-patient: after resuscitation they must be disposed of and replaced, always respecting the expiry date printed on the packaging. Indicated for adult patients (over 8 years of age or weighing more than 25 kg).

3. Technical Specifications

Main features of the adult radiolucent electrode series with internal cable to which this reference belongs (Ref. Cahnos F7762):

Parameter Specification
Reference Cahnos (SKU) F7762
Product type Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable
Compatible brands Marquette GE and Esaote
Compatible models Marquette 1250 First Responder, 1500 First Responder, Responder 2000 (documented family: Responder 3000, with adapter cable); Esaote MDF and MDF Plus (verify connector)
Patient type Adult (older than 8 years / more than 25 kg)
Cable configuration Integrated internal cable: direct connection to the equipment electrode socket
Radiotransparency Yes (electrode and cable), suitable for imaging procedures
Functions External defibrillation, synchronized cardioversion, non-invasive transcutaneous pacing and ECG monitoring
Supported shocks 50 shocks up to 360 J (adult series)
ECG monitoring Max. 24 h
Adhesive ring width 1 cm
Total / active area (per electrode) 148 cm² total / 95 cm² active*
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material 1 mm thick medical foam
Connection type Safety anti-shock connector / clip (depending on the equipment model), with internal cable
Use Single-use, disposable, non-sterile; free from latex and phthalates
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box
Operating temperature Between 0 °C and +50 °C
Storage Dry place, between +5 °C and +35 °C
Shelf life 30 months from the date of manufacture (expiry date indicated on the packaging)
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10

*Values for the adult series of this electrode family; confirm with the technical data sheet of the supplied batch and with the equipment manual before use in tenders.

3.1 Compatibility with defibrillators

Equipment brand Compatible models Cable / connection
Marquette GE 1250 First Responder, 1500 First Responder, Responder 2000 (documented family: Responder 3000, with adapter cable) Equipment internal cable; verify connector fit
Esaote MDF, MDF Plus (documented family) Equipment internal cable; confirm the exact model and connector before replacement

Always verify the correct fit of the connector in the equipment’s electrode socket before clinical use.

4. Equivalences and Cross-References

Reference F7762 is the Cahnos distribution code for this adult radiolucent electrode compatible with Marquette GE and Esaote; it is not an official reference of the equipment manufacturer. The connector and energy management of each defibrillator are proprietary, so equivalences with other brands are comparable only at category level and are not interchangeable 1:1. The following cross-references have a confirmed code in product data sheets from an authorised technical manufacturer-distributor:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
AB Medica Group (Lessa) Adult radiolucent electrodes for GE Marquette 1500 First Responder 99.835.68 Comparable by category (not interchangeable 1:1) Same functional profile: adult radiolucent electrode for the Marquette GE platform (1250/1500 First Responder) with cable and connector included. Code confirmed in the manufacturer-distributor product data sheet; connector and discharge protocol proprietary to the equipment. Verify fit before replacement.
AB Medica Group (Lessa) Adult electrodes for GE Marquette Responder 2000 (without GE 22338301 cable) 99.835.24 Comparable by category (not interchangeable 1:1) Covers the adult Responder 2000 platform with the equipment’s internal cable; the public data sheet does not confirm radiolucency, so it is not interchangeable 1:1 with this reference in imaging procedures. Code confirmed in the manufacturer-distributor product data sheet.

There is no equivalence table validated by the equipment manufacturer (GE Healthcare / Esaote) authorising the replacement of original pads with third-party electrodes: defibrillation platforms use proprietary connectors, analysis algorithms and energy management and are not interchangeable 1:1 between brands (e.g. Philips HeartStart, ZOLL, Schiller, Stryker LIFEPAK or Bexen). Consult the technical department before use in tenders.

5. Selection tips and variants of interest

Confirm the model and connector of the equipment: verify that your defibrillator is a Marquette GE (1250 or 1500 First Responder, Responder 2000/3000) or an Esaote (MDF, MDF Plus) and that the internal cable connector fits correctly into the electrode socket before clinical use. If in doubt, contact the Cahnos technical department stating the model and serial number.

Do not confuse the paediatric and adult versions: this pair is for patients over 8 years of age or weighing more than 25 kg. For paediatric patients with the same connector family, reference F7962P is available (standard paediatric with internal cable, Marquette GE/Esaote).

Variants of the same family on Cahnos: if you do not need radiotransparency, for the same Marquette GE/Esaote platform with internal cable, reference F7962 (adult standard) is available; for other platforms in the radiotransparent category with internal cable you will find F7752 (Physio-Control / Bexen / Mindray) and F7761 (Nihon Kohden). Always verify which connector family corresponds to each device.

Storage and expiry: check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date. For volume orders or tenders, contact our technical-commercial department indicating the exact models of your fleet.

Additional information

Product type

Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable

Compatible brands

Marquette GE and Esaote

Compatibility

Marquette 1250 First Responder, 1500 First Responder, Responder 2000 (documented family: Responder 3000, with adapter cable); Esaote MDF and MDF Plus (verify connector)

Indicated population

Adult (older than 8 years / more than 25 kg)

Cable type

Integrated internal cable (direct connection to the equipment socket)

Radiotransparency

Yes (electrode and cable)

Functions

External defibrillation, synchronized cardioversion, non-invasive transcutaneous pacing and ECG monitoring

Supported shocks

50 shocks up to 360 J (adult series)

ECG monitoring

Max. 24 h

Adhesive ring width

1 cm

Total area

148 cm² per electrode (adult series; verify batch data sheet)

Active area

95 cm² per electrode (adult series; verify batch data sheet)

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm thick medical foam

Connection type

Safety anti-shock connector / clip (depending on model)

Use

Single-use, disposable, non-sterile; free from latex and phthalates

Presentation

1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box

Operating temperature

Between 0 °C and +50 °C

Storage

Dry place, between +5 °C and +35 °C

Shelf life

30 months from date of manufacture (expiry on packaging)

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10